GE DCD330GBWC Bedienungsanleitung

GE Trockner DCD330GBWC

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für GE DCD330GBWC (20 Seiten) in der Kategorie Trockner. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/20
Commercial
GEAppliances.com
DCB330
DCD330
134205200 175D1807P420 49-90156 11-02 JR
Safety Instructions . . . . . . . . . 2–5
Care and Cleaning
Care and Cleaning . . . . . . . . . . . .6
Installation Instructions
Countdown Display . . . . . . . . . . 17
Electrical Installation for
Electric Dryers . . . . . . . . . . . 13, 14
Electrical Requirements . . . . . . . . 8
Exhausting the Dryer . . . . . . . 9, 10
Gas Connection for Gas Dryers . . 15
Gas Supply Requirements . . . . . 10
Location of Your Dryer . . . . . . . . 11
Mobile Home Installation . . . . . 12
Preparing to Install Your Dryer . . 7
Reversing the Door Swing . . . . . 16
Customer Service
Customer Service . . . . . Back Cover
General Principles of
Good Practice . . . . . . . . . . . . . . . 19
Warranty . . . . . . . . . . . . . . . . . . . 18
Write the model and serial
numbers here:
Model # __________________
Serial # __________________
You can find them on the label
on the front of the left side of
the door opening.
Owner’s Manual and
Installation Instructions
Dryers
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
2
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire
or explosion, electric shock, or to prevent property damage, personal injury, or death.
FOR GAS DRYERS: YOU MUST POST IN A PROMINENT LOCATION
1. Instructions to follow if the user smells gas: Contact your local gas
supplier for information to be displayed.
2. Instructions concerning flammable materials as follows:
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
California Safe Drinking Water and Toxic Enforcement Act
This act requires the governor of California to publish a list of substances known to the state to cause cancer,
birth defects or other reproductive harm and requires businesses to warn customers of potential exposure
to such substances.
Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide,
formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be
minimized further by properly venting the dryer to the outdoors.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Customer Service Care and Cleaning Safety InstructionsInstallation Instructions
â– Properly ground dryer to conform with all
governing codes and ordinances. Follow details
in the Installation Instructions section.
â– Install or store where it will not be exposed to
temperatures below freezing or exposed to the
weather.
â– Connect to a properly rated, protected and sized
power supply circuit to avoid electrical overload.
â– Remove all sharp packing items and dispose of
all shipping materials properly.
â– In fulfilling the specific needs of different
commercial installations the purchaser of this
dryer may wish to locate the coin box and
controls in any of a number of locations.
The responsibility for the proper performance
of this work lies solely with the purchaser.
It should be done by properly trained and
qualified personnel, and in accordance with
local code requirements.
â– Any coin box or similar device added to
the dryer, either electrically or mechanically,
should be properly grounded.
â– Remove any accumulated time by manually
rotating timing cam in the coin box
counterclockwise until switch shuts off. Apply
a slight additional counterclockwise pressure to
further seat drive. Make certain not to turn cam
past switch shutoff position. Otherwise, one
increment of time will be gained. Switches are off
when the plastic switch actuating arm (inner)
is down and all 3 switch buttons are depressed.
Exhaust/Ducting:
This dryer MUST be exhausted to the outside.
Use only rigid metal or flexible metal 4″
diameter ductwork inside the dryer cabinet or
for exhausting to the outside. USE OF PLASTIC
OR OTHER COMBUSTIBLE DUCTWORK CAN
CAUSE A FIRE. PUNCTURED DUCTWORK CAN
CAUSE A FIRE IF IT COLLAPSES OR BECOMES
OTHERWISE RESTRICTED IN USE OR DURING
INSTALLATION.
Follow details in the Installation Instructions section.
2
1
PROPER INSTALLATION
This dryer must be properly installed and located in accordance with the Installation Instructions
before it is used.
3
Customer ServiceCare and CleaningSafety Instructions Installation Instructions
GEAppliances.com


Produktspezifikationen

Marke: GE
Kategorie: Trockner
Modell: DCD330GBWC

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE DCD330GBWC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Trockner GE

Bedienungsanleitung Trockner

Neueste Bedienungsanleitung für -Kategorien-