GE ADKW50LN Bedienungsanleitung

GE Luftreiniger ADKW50LN

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für GE ADKW50LN (36 Seiten) in der Kategorie Luftreiniger. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
Safety Instructions ............................ 2, 3
Operating Instructions
About the Controls
on the Dehumidifier ................................... 4
Automatic Defrost ........................................ 5
Choosing a Location ................................... 5
How the Dehumidifier Operates ........... 5
Removing Collected Water ................... 6
Water Level ..................................................... 6
Care and Cleaning
Grille and Case ............................................... 7
Water Bucket .................................................. 7
Troubleshooting Tips ........................... 8
Consumer Support
Consumer Support .....................................12
Product Registration ............................9, 10
Warranty ........................................................11
*EnErgy Star ® labeled product
As an EnErgy Star® partner, GE has
determined that this product meets the
EnErgy Star® guidelines for energy efficiency.
GEAppliances.com
Dehumi iersdif
49-7637 01-10 GE
ADKW30*
ADKW50*
ADKW65*
Owners Manual
Write the model and serial numbers
here:
Model # ________________________
Serial # _________________________
You can find them on a label on the back
of the dehumidifier.
Déhumidificateur
Deshumedificador
Manuel d’utilisation
Manual del propietario
La section française commence à la page 15
La sección en español empieza en la página 25
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
When using this dehumidifier, always follow basic safety precautions, including the following:
n Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
n This dehumidifier must be properly
installed and grounded as described
in this manual before it is used.
n Never operate this dehumidifier in an
area that is likely to accumulate standing
water.
If this condition develops, for your safety
disconnect the power supply before
stepping into the water.
n Never unplug your dehumidifier by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
n If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
n Turn the dehumidifier and unplug it OFF
before making any repairs or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
n For your safety, do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
n All dehumidifiers contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants,
check with the company handling disposal
about what to do.
n Do not use outdoors.
n This dehumidifier is intended for
indoor residential applications only.
This dehumidifier should not be used
for commercial or industrial applications.
These R410A Dehumidifier Systems require
contractors and technicians to use tools,
equipment and safety standards approved
for use with this refrigerant. DO NOT use
equipment certified for R22 refrigerant only.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric
shock hazard from this appliance.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The dehumidifier should always be
plugged into its own individual electrical
outlet, which has a voltage rating matching
the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits, which
could cause a fire hazard from overheated wires.
HOW TO CONNECT ELECTRICITY
2
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
3
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
GEAppliances.com
Because of potential safety hazards under
certain conditions, we strongly recommend
against the use of an extension cord.
However, if you must use an extension
cord, it is absolutely necessary that it be
a UL-listed, 14 gauge, 3-wire grounding
type appliance extension cord having
a grounding type plug and outlet and
that the electrical rating of the cord be
15 amperes (minimum) and 125 volts.
USE OF EXTENSION CORDS
What dehumidifier do you need?
Condition without dehumidification— Area (in square feet)
During warm and humid outdoor conditions 500 1000 1500 2000 2500 3000 3500
Moderately dampSpace feels damp
and has musty odor only in humid weather. ADKW30 ADKW30 ADKW30 ADKW30
Very damp—Space always feels damp and has musty
odor. Damp spots show on walls or floor. ADKW30 ADKW30 ADKW30 ADKW50
Wet—Space feels and smells wet. Walls or floor sweat,
or seepage is present. ADKW30 ADKW30 ADKW50 ADKW50
Extremely wet—Laundry drying, wet floor, high-load conditions ADKW30 ADKW30 ADKW50 ADKW50 ADKW65
Table indicates recommended GE dehumidifier models, based on the area of the space to be dehumidified and the conditions that would exist in that space
when a dehumidifier is not in use. Dehumidification variables also include such other factors as climate, laundry equipment, number of family members,
number of doors and windows and degree and intensity of area activity.


Produktspezifikationen

Marke: GE
Kategorie: Luftreiniger
Modell: ADKW50LN

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE ADKW50LN benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftreiniger GE

Bedienungsanleitung Luftreiniger

Neueste Bedienungsanleitung für -Kategorien-