SAFETY INFORMATION . . . . . . . . .3
OPERATING INSTRUCTIONS
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Other Features . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions . . . . . . . . . . . . . . . . .6
How the Dehumidifier Operates . . . . . . . . .7
Automatic Defrost . . . . . . . . . . . . . . . . . . . . .7
Choosing a Location . . . . . . . . . . . . . . . . . . .7
Removing Collected Water . . . . . . . . . . . . .8
Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Bucket Operation . . . . . . . . . . . . . . . . . . . . . .8
CARE AND CLEANING
Grille and Case . . . . . . . . . . . . . . . . . . . . . . . .9
Water Bucket . . . . . . . . . . . . . . . . . . . . . . . . .9
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
TROUBLESHOOTING TIPS . . . . . . 10
CONSUMER SUPPORT
Limited Warranty . . . . . . . . . . . . . . . . . . . . . 11
Consumer Support . . . . . . . . . . . . . . . . . . . . 12
ENGLISH/ESPAÑOL
49-5000627 Rev. 0 3
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY INFORMATION
WARNING For your safety, the information in this manual must be followed to minimize the risk of
re, electric shock or personal injury.
Use this appliance only for its intended purpose as
described in this Owner’s Manual.
This dehumidifier must be properly installed and
grounded as described in this manual before it is
used.
Never operate this dehumidifier in an area that is
likely to accumulate standing water. If this condition
develops, for your safety disconnect the power supply
before stepping into the water.
Never unplug your dehumidifier by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
Immediately replace all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced
with a new power supply cord obtained from the
manufacturer and not repaired. Do not use a cord that
shows cracks or abrasion damage along its length or
at either the plug or connector end.
If the receptacle does not match the plug, the
receptacle must be changed out by a qualified
electrician
If the SUPPLY CORD is damaged, it must be
replaced by the manufacturer, its service agent or
similarly qualified person in order to avoid a hazard.
The appliance shall be installed in accordance with
national wiring regulations.
Turn the dehumidifier OFF and unplug it before
cleaning.
Haier does not support any servicing of the
dehumidifier. We strongly recommend that you do not
attempt to service the dehumidifier yourself.
For your safety, do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
All dehumidifiers contain refrigerants, which under
federal law must be removed prior to product
disposal. If you are getting rid of an old product
with refrigerants, check with the company handling
disposal about what to do.
Do not use outdoors.
This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be
used for commercial or industrial applications.
These R410A Dehumidifier Systems require
contractors and technicians to use tools, equipment
and safety standards approved for use with this
refrigerant. DO NOT use equipment certified for R22
refrigerant only.
This appliance can be used by persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved.
WARNING USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Ŷ'2127XVHDQH[WHQVLRQFRUGZLWKWKLV'HKXPLGLILHU
Ŷ'2127XVHVXUJHSURWHFWRUVRUPXOWLRXWOHWDGDSWRUV
with this Dehumidifier.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord. For personal
safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The dehumidifier should always be plugged into its own
individual electrical outlet, which has a voltage rating
matching the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits, which could cause a
fire hazard from overheated wires.
RECYCLING INFORMATION
For appliance recycling information please visit www.geappliances.com/recycling.
449-5000627 Rev. 0
Controls
NOTE: When the bucket is full or removed, the controls
cannot be set.
1. Power Pad
Press to turn the dehumidifier on and off.
NOTE: Turning off the power by pressing the Power button
does NOT disconnect the appliance from power supply.
2. Fan Speed Pad
Controls the fan speed.
Press to select either High, Medium, Low, or Smart Dry fan
speed.
Set the fan control to High for maximum moisture removal.
When the humidity has been reduced and quiet operation is
preferred, set the fan control to Medium or Low.
Smart Dry compares the set humidity level with the actual
humidity and adjusts the fan speed automatically.
3. Display
Shows the set % humidity level while setting, then shows the
actual (+/– 5% accuracy) room % humidity level.
4. Humidity Set Control Pads
The humidity level can be set within a range of 35%
RH (Relative Humidity) to 80% RH (Relative Humidity) in 5%
increments or in Nonstop mode for continuous operation. To
set the unit for continuous operation, press the pad until
the “Nonstop” indicator light is illuminated.
NOTE: If Nonstop is selected, the dehumidifier will operate
continuously at its maximum dehumidification settings if
attached to a hose to drain or until the bucket is full.
For drier air, press the pad and set to a lower percent
value (%).
For damper air, press the pad and set to a higher percent
value (%).
When you first use the dehumidifier, set the humidity control
to 45% or 50%. Allow at least 24 hours for the dehumidifier
to achieve the humidity level. If you still have damper air
than desired, set the humidity level to a lower setting or
select Nonstop for maximum dehumidification.
5. Filter Timer
After 250 hours of operation, the Clean the Filter indicator
light will glow to remind you to clean the filter. Remove the
filter and clean it.
Press and hold button for 3 seconds to reset the filter Filter
reminder. See the Care and Cleaning section.
6. Delay Off
While the dehumidifier is operating press the Delay button.
Press the / buttons to select the number of hours you
want the dehumidifier to continue to operate before turning
Off.
NOTE: After displaying the time, the Display will revert to
showing the current humidity after 5 seconds have passed.
Pressing the Delay button will display the number of hours
left on the delay.
Delay On
While the dehumidifier is off press the Delay button.
Press the buttons to select the number of hours you /
want the dehumidifier to remain off before turning On.
NOTE: The display will show the number of hours left until
the dehumidifier turns on.
To cancel the Delay:
Press the Delay button once, the hours remaining on the
Delay will appear on the display. Press the button Delay
again and the Delay will be cancelled.
7. Empty Indicator
The “Empty” indicator will blink when the bucket is ready
to be emptied, or when the bucket is removed and/or not
replaced in the proper position.
OPERATING INSTRUCTIONS
Controls
Appearance may vary by model.


Produktspezifikationen

Marke: GE
Kategorie: Luftreiniger
Modell: ADHR35LB

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE ADHR35LB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftreiniger GE

Bedienungsanleitung Luftreiniger

Neueste Bedienungsanleitung für -Kategorien-