GAS COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY:
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
 Donottrytolightanyappliance.
 Donottouchanyelectricalswitch;donotuseanyphoneinyourbuilding.
 Immediatelycallyourgassupplierfromaneighbor'sphone.Followthegassupplier'sinstructions.
 Ifyoucannotreachyourgassupplier,calltheredepartment.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Cooktop Dimensions
Cooktop Cutout Dimensions
AB
C
D
E
30" Min.
NOTE: Wiring diagrams for these appliances are enclosed in this booklet. P/N 318201452 (1302) Rev. H
English – pages 1-10
Español – páginas 11-22
Wiring Diagram - pages 24
Printed in Canada
Figure 1
MODEL A. B. C. LENGTH WIDTH DEPTH
CUTOUT DIMENSIONS
D. E. LENGTH WIDTH
Min. Max. Min. Max.
26" Model 25 ¾" 21 9/16" 3 ½" 25" 25" 20 ½" 20 ½"
30" Model 30" 21 ½" 3 1/8" 26 5/8" 26 7/8" 19" 19 3/8"
36" Model 36" 18 5/8" 3 ¼" 34 ¼" 34 3/8" 16 5/8" 16 ¾"
GAS COOKTOP INSTALLATION INSTRUCTIONS
2
Figure 2 COUNTERTOP CUTOUT OPENING
To eliminate the risk of
burns or fire by reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5"
beyond the bottom of the cabinets.
A Min.
Dimensions is the Minimum J
Distance Required Between
Rear of Top Panel to Adjacent
Combustible Surfaces.
18" Min.
Clearance
30" Min. Clearance
Between the Top
of the Cooking
Platform and
Unprotected Wood
or Metal
Cabinet
24"
13" Max. Depth
For Cabinet
Installed Above
Cooktop.
Dimension is the H
Minimum Clearance
Required From Right
Side of Top Panel to
Adjacent Combustible
Surface.
Dimension is the K
Minimum Clearance
Required From Left
Side of Top Panel to
Adjacent Combustible
Surface.
Allow Dimension Space Below L
Cooktop for Piping and Electrical
Connections.
Note: (For 26" and 36" Models Only). The rear edge of opening
must be 1 ½" from rear face of base cabinet. If countertops are
ordered from a supplier other than cabinet supplier, the relation of
the cutout in relation to the rear of the cabinet shall be specified.
Model H J K L
26" Model 1" ½" 1" 8½"
30" Model 0" 2" 2" 8 1/8"
36" Model 1" 2½" 1" 8¼"
GAS COOKTOP INSTALLATION INSTRUCTIONS
3
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for
future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Installation of these cooktops must conform with local
codes or, in the absence of local codes, with the National
Fuel Gas Code ANSI Z223.1—latest edition.
These cooktops has been design certified by American
Gas Association (A.G.A.). As with any appliance using
gas and generating heat, there are certain safety
precautions you should follow. You will find them in the
Use and Care Guide, read it carefully.
Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
These cooktops must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70—latest edition. See grounding instructions
farther in this manual.
Theinstallationofappliancesdesignedfor
manufactured (mobile) home installation must
conform with Manufactured Home Construction
and Safety Standard Title 24CFR, Part 3280
[Formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, (Part
280)] or when such standard is not applicable the
Standard for Manufactured Home Installation
1982 (Manufactured Home Sites, Communities
and Set-Ups), ANSI Z225.1/NFPA 501-A- latest
edition, or with local codes.
• Aircurtainorotheroverheadhoods,whichoperate
by blowing a downward air flow on to a range, shall
not be used in conjunction with gas ranges other
than when the hood and range have been designed,
tested and listen by an independent test laboratory
for use in combination with each other.
Do not store items of interest to children in the
cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to reach
items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.
Adjust surface burner ame size so it does not
extend beyond the edge of the cooking utensil.
Excessive ame is hazardous.
Never use your cooktop for warming or heating
the room. Prolonged use of the cooktop without
adequate ventilation can be hazardous.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other
appliance. Explosions or fires could result.
The electrical power to the cooktop
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Safety Tips - Gas Surface Units
Your new cooktop has been tested to meet the most
rigid safety standards. You can feel confident while
using it but use these safety suggestions to help avoid
accidents that can cause injury to the user or damage to
the cooktop.
Note: All safety tips listed may not apply to your model.
Plug the unit into a 120-volt grounded outlet only.
Do not remove the grounding prong from the plug. If
in doubt about the grounding of the home electrical
system, it is the personal responsibility and obligation
of the owner to contact a qualied electrician and
have an ungrounded receptacle replaced by a properly
grounded three-prong wall receptacle, in accordance
with the National Electrical Code. Do not use an
extension cord with this unit.
Donotrepairorreplaceanypartoftheunitunless
specically recommended in this guide. Call a qualified
technician for all other servicing.
Clean only the parts of the cooktop as instructed in
the Use and Care Guide.
• Becertainallpackingmaterialsareremovedfrom
the unit before operating to prevent fire or smoke
damage, should the packing material ignite.
Ventilating Hoods
Cleanventilatinghoodfrequently.Greaseshouldnot
be allowed to accumulate on hood or filter.
Whenamingfoodsunderthehoodturnthefanoff.
The fan, if operating, may spread the flame.


Produktspezifikationen

Marke: Frigidaire
Kategorie: Herde
Modell: FFGC3005LW
Breite: 762 mm
Tiefe: 546.1 mm
Gewicht: 13600 g
Produktfarbe: Weiß
Steuerung: Drehregler
Höhe: 79.4 mm
AC Eingangsspannung: 120 V
AC Eingangsfrequenz: 60 Hz
Eingebautes Display: Nein
Paketgewicht: 15876 g
Geräteplatzierung: Integriert
Einfach zu säubern: Ja
Stromstärke: 15 A
Kochfeldtyp: Gaskochfeld
Anzahl Herdplatten/Kochzonen: 4 Zone(n)
Anzahl der Gasbrenner: 4 Zone(n)
Anzahl der elektrischen Herdplatten: 0 Zone(n)
Typ Kochzone 1: Regelmäßig
Kochzone 1 Form: Rund
Position Kochzone 1: Hinten links
Stromquelle Kochzone 1: Gas
Leistung Kochzone 1: 2600 W
Typ Kochzone 2: Regelmäßig
Kochzone 2 Form: Rund
Position Kochzone 2: Links vorne
Brenner/Kochzone 2 Stromquelle: Gas
Leistung Kochzone 2: 2600 W
Typ Kochzone 3: Regelmäßig
Kochzone 3 Form: Rund
Position Kochzone 3: Hinten rechts
Stromquelle Kochzone 2: Gas
Leistung Kochzone 3: 2600 W
Typ Kochzone 4: Regelmäßig
Kochzone 4 Form: Rund
Position Kochzone 4: Hinten rechts
Stromquelle Kochzone 3: Gas
Leistung Kochzone 4: 2600 W
Steuerungsposition: Oben rechts
Anschlusswert (elektrisch): - W
Anschlusswert (Gas): - W
Einbauraum Höhe: 206.4 mm
Einbauraum Tiefe (max): 492.1 mm
Einbauraum Tiefe (min): 482.6 mm
Standard Herdplatte/Kochzone: 2637.6 W
Elektrische Zündung: Ja
Pfannenunterlagenmaterial: Edelstahl

Brauchst du Hilfe?