USERGUIDE
Moisture Meter
Model MO210
MO210-EU-EN V2.1 8/12
2
Introduction
Thank you for selecting the Extech Model MO210. This device is shipped fully tested and calibrated
and, with proper use, will provide years of reliabl website (www.extech.com) e service. Please visit our
to check for the latest version of this User Guide, Product Updates, and Customer Support.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages
may be present
Double insulation
Safety Notes
ï‚· Do not exceed the maximum allowable input range of any function.
ï‚· Set the function switch OFF when the device is not in use.
ï‚· Remove the battery if the device is to be stored for longer than 60 days.
ï‚· Never dispose of batteries in a fire. Batteries may explode or leak.
ï‚· Never mix battery types. Always install new batteries of the same type.
Warnings
ï‚· Set function switch to the appropriate position before measuring.
ï‚· Do not measure current on a circuit whose voltage exceeds 600V.
ï‚· When changing ranges always om the circuit under test. disconnect the test leads fr
Cautions
ï‚· Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
ï‚· Always remove the test leads before replacing the battery.
ï‚· Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair or replace any damage before use.
ï‚· Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
ï‚· Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
ï‚· If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
MO210-EU-EN V2.1 8/12
3
Description
Meter Description
1. Measurement electrode pin
2. Cutoff switch
3. LCD (detail below)
4. Hand grip
5. Verification Test Points
6. Battery check Test Points
7. Removable cap
8. Material Selector Switch
Display Description
1. Graphical Display
2. Numerical Reading
3. Units
4. Low Battery Indicator
5. Solid lines – even number
6. Dashed lines – odd number
Wood Scale Building Material
Scale
4 4
2 2
3 3
5
5
6
6
1


Produktspezifikationen

Marke: Extech
Kategorie: Messgeräte
Modell: MO210

Brauchst du Hilfe?

Wenn Sie Hilfe mit Extech MO210 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Messgeräte Extech

Bedienungsanleitung Messgeräte

Neueste Bedienungsanleitung fĂ¼r -Kategorien-