Elica Calabria ECL630S4 Bedienungsanleitung

Elica Dunstabzugshaube Calabria ECL630S4

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Elica Calabria ECL630S4 (10 Seiten) in der Kategorie Dunstabzugshaube. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/10
Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
GuĂ­a de
instalaciĂłn, uso y
mantenimiento
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0152213
Printed in Mexico
10/18
Models: KIT0154387
9
Install In-Blower System
NOTE: The blower motor housing can be mounted using
4 holes from either the inlet side or the outlet side of the
blower.
A
A
A
A
A
A
A. Mounting holes
1 Position the in-line blower motor housing in its mounting
location and mark the 4 mounting hole locations.
2 Drill 4 mounting pilot holes using a ³⁄₁₆” (0.5 cm) drill bit.
3 Attach the in-line blower motor housing to the mounting
location with mounting (4) 6.3x60 mm screws and
(4)4x1.8 washers(Parts are included with the range hood
motor kit)
4 If removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5 If removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1 Determine and make all necessary cuts for the vent
system. IMPORTANT: When cutting or drilling into the
ceiling or wall, do not damage electrical wiring or other
hidden utilities.
2 Determine the location where the ¹⁄₂” (1.3 cm) wiring
conduit will be routed through the ceiling or wall between
the in-line blower and the range hood.
3 Drill a 1¹⁄₄” (3.2 cm) hole at this location.
4 Locate the electrical terminal boxes in the in-line blower
housing and range hood Remove the terminal box covers .
and set the covers and screws aside.
A
B
A. Terminal Box Cover
B. Knockout
5 Remove the electrical knockout from the in-line blower
housing and range hood (see the range hood installation
instructions) to prepare for the installation of the UL
listed or CSA approved ¹⁄₂” (1.3 cm) wiring conduit and
conduit connector.
6 With the range hood mounted (see the range hood
installation instructions), run the ¹⁄₂” (1.3 cm) wiring
conduit between the in-line blower motor housing and the
range hood. Pull enough ¹⁄₂” wiring conduit to allow for
easy connection to the terminal boxes in the in-line blower
housing and range hood.
A
B
C
D
F
E
A. In-Line Blower Kit
B. Range Hood Terminal
Box
C. Power Supply wiring
Conduit
D. In-Line Blower Wiring
Conduit (not included)
E. In-Line Blower Terminal
Box
F. In-Line Motor Electrical
Plug Cable
11
Make Electrical Connection Inside Range Hood
Between In-Line Blower System
and Range Hood
1 With the range hood mounted (see the range hood
installation instructions), locate the wiring cable connector
inside the range hood.
C
D
A
B
A. Range Hood Junction Box
B. Range Hood knockout for Wire
Connector Assembly
C. Wire Connector Assembly (provided
in the In-Line Blower Kit)
D. Power Supply Wiring Conduit
2 Connect the 6 wire connector assembly supplied with
the in-line blower motor system to the mating connector
from the range hood.
BA
A. Wire Connector Assembly (provided in
the In-Line Blower Kit)
B. Hood Insert Blower Connector
3 Install UL listed or CSA approved strain reliefs. Run
through the strain reliefs the 6 wire connector
and the In-Line Blower wiring conduit (not incluided
leaving enough wire length to make the wiring
connections.
4 Tighten the strain relief screws.
5 Connect the wires from the 6- wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
Connect the green (or green/yellow) ground NOTE:
wire from the wiring conduit to the green (or bare)
ground wire from the home power supply and to the
and to the green/yellow ground wire from the 6-wire
connector assembly (H) using UL listed wire connectors
(see the “Make Electrical Power Supply Connections
to Range Hood” section in the range hood installation
instructions).
A
B
C
D
E
F
G
H
I
A. Strain relief
B. UL listed wire
connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/
green) and green /
yellow wires
I. Motor electrical plug
cable
6 Connect the home power supply wiring to the range
hood following the instructions that are supplied with the
range hood.
7 Reinstall the range hood terminal box cover.
8 Reconnect power.


Produktspezifikationen

Marke: Elica
Kategorie: Dunstabzugshaube
Modell: Calabria ECL630S4

Brauchst du Hilfe?

Wenn Sie Hilfe mit Elica Calabria ECL630S4 benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dunstabzugshaube Elica

Bedienungsanleitung Dunstabzugshaube

Neueste Bedienungsanleitung fĂźr -Kategorien-