Pb
LEAD FREE
in compliance with s RoHS
In case of guarantee
or post-guarantee
service, send the
thermostat to the
distributor’s or manu-
facturer’s address.
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
MADE IN CZECH REPUBLIC
MADE IN CZECH REPUBLIC
BT0
BT0
BT0
BT01
1
1
12
2
2
2
BT012
and a wall-mounted receiver
The great advantage is the two-way communication, quick setting and change of the required
temperature by simply turning the knob on the transmitter. The transmitter is portable, or it can be
installed on the wiring box in the reference room. The receiver is equipped with the code self-
learning system and the E-EPROM memory, which preserves the saved code even at power
failure. The wireless version enables simple and quick installation; therefore, there is no need for
laborious and time-consuming installation of a line between the thermostat and boiler with
penetration through fl oors. The coverage of the set can reach up to 35 m.
• Receiver power supply 230 V/ 50 Hz.
• Receiver with the CODE SELF-LEARNING
system and the E-EPROM memory (saving
the code even at power failure).
• Two-wire connection to the boiler.
• Indication LED for signalization of the
states
- power supply indication
- failure state
- relay closed.
receiver - wall-mounted
transmitter
• Simple control element for temperature
setting – knob.
• Indication of the boiler switching and error
states by means of a red LED.
•Night attenuation – button for quick
selection of the night attenuation
(automatic decline by 3 °C for the 8-hour
period).
• Anti-freeze temperature .
• Optional internal frame of a different colour
can be bought (according to the sampler at
www.elbock.cz) for a perfect harmony in
the interior.
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel.: +420 541 230 216
EU DECLARATION OF CONFORMITY
Hereby, ELEKTROBOCK CZ s.r.o. declares that
the radio equipment type BT012 is in compliance
with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following
internet address: www.elbock.cz
TECHNICAL PARAMETERS
IMPORTANT INFORMATION
TWO-WAY COMMUNICATION
- Providing for reliable signal transmission
and enabling return information acquisition
www.elbock.cz
Receiver
Power supply 230 V/ 50 Hz
Communication type two-way
Frequency 433.92 MHz
Range 200 m (free area)
25 m (built-up area)
Sensitivity < -952 dBm
Output relay, max. 16 A
Protection IP20
Protection class II
Working temperature 0°C to +40°C
Dimensions 110 x 80 x31 mm
Transmitter
Power supply 2 x1.5V alkaline AA batteries
(are included)
Communication type two-way
Hf power < 10 mW
Frequency 433.92 MHz
Hysteresis 0,4°C
Adjustable temp. range 11 to 29°C
(anti-freeze min. 3°C)
Temperature setting by 1°C (from 11°C)
Measurement accuracy ± 1°C
Protection IP20
Battery life 5 years acc. to the battery type used
Working temperature 0°C to +40°C
If... Cause and solution...
the red LED is fl ashing on the transmitter
3 times in 8 s
Low battery indication
Replace the batteries; see page 3
the red LED is fl ashing on the transmitter
2 times in 8 s
Signal transmission failure between the
transmitter and receiver
Check the connection of the receiver; see
page 2; on the transmitter, push long (for
approx. 3 s) the button to test the
connection (the relay on the receiver must
switch several times).
the green LED is fl ashing on the receiver Empty memory; the transmitter code has not been
learned
Perform the code learning; see page 2
the green LED is permanently lit and the red
one is fl ashing on the receiver
The receiver is in the error state (8 min OFF and 2
min ON)
Check the transmitter and test the connection
the green and red LED are fl ashing alternately
on the receiver
The code-learning mode; the receiver is awaiting the
code
On the receiver, push long (for approx. 3 s)
the button
the both LED is lit on the receiver, but the
relay has not been switched
Output circuit failure
Contact the manufacturer immediately.
RECEIVER INSTALLATION
WIRING DIAGRAM
CODE LEARNING
- Lift off the front cover of the receiver acc. to Fig. 1, 2.
- Fix the receiver to the wall (or directly to the wiring box).
- Switch off the main circuit breaker.
- Connect the receiver to the boiler according to the diagram (on the
boiler, use the terminals for wires of the room thermostat 2).
- Connect the receiver to the mains 230 V / 50 Hz.
- Switch on the main circuit breaker; the green LED lights up on the
receiver; thus the receiver is ready for further setting
Owing to disturbance of the signal reception, install the receiver
(in the interior) as far as possible (no less than 0.5 m) from
big metal objects and outside high-current power lines! We
recommend that the installation be done by a person properly
qualifi ed in electrical engineering!
Use if the receiver memory has been erased – the green diode is fl ashing!
1) Push the receiver’s “FUNCTION BUTTON” for about 1 s; the green and red LEDs start fl ashing
alternately; and the receiver is awaiting the code (“learning mode”).
2) On the transmitter (after insetting batteries, see page 3), push the button for approx. 5s (push it until
the red LED on the transmitter lights up); then a signal is send out to the receiver and the TEST starts
up.
3) The code receipt in the receiver is indicated by simultaneous fl ashing of the green and red LED; thus
the code has been learnt. After the code receipt, the output relay is switched several times to verify
correct function of BT012 (the so-called TEST).
BOILER
230 V/50Hz
NL
TRANSMITTER DECRIPTION
TRANSMITTER INSTALLATION
TRANSMITTER MODES
- Lift off the front cover of the transmitter according to Fig. 5.
- Fix the back cover to the wall (or directly to the wiring box), see Fig. 6.
- Remove the protective paper from the batteries; the transmitter will be fully functional (batteries are
included in the delivery of the BT012 purchased).
- Snap back the front cover onto the back one, see Fig. 8–9.
- When replacing the batteries, heed their correct polarity (Fig. 7).
- The necessity to replace the batteries is indicated by the red LED; it fl ashes 3 times in 8 s.
- Always use alkaline batteries 2 × 1.5 V, type AA! (Do not use rechargeable batteries.)
Note: Dispose of old batteries in conformity with regulations on hazardous waste handling!
Set the
required
temperature,
e.g. to 22 °C.
At 10 pm, push
shortly
(for approx. 1 s)
the button.
The thermostat
automatically
reduces the
required
temperature by
3 °C for the period
of 8 hours from
pushing of the
button.
Temperature setting/change:
- By simply turning the knob, set the required temperature by the scale (± 1 °C from 11 °C).
- SWITCHING ON of the boiler is indicated by the red LED; it fl ashes once per 8 s.
Night attenuation:
It is used to automatically reduce the temperature by 3 °C for the 8-hour period. This cycle is
automatically repeated every day.
- Within the required time, shortly push (for approx. 1 s) the button; the diode fl ashes 4 times;
thus the mode is active.
- If you again shortly push the button during the night attenuation, the starting hour of the night attenuation
changes and a new 8-hour cycle starts to count down.
- By turning the temperature change knob, you can cancel the NIGHT ATTENUATION!
EXAMPLE:
Fig.5
Fig.6
Fig.9Fig.8Fig.7
Indication LED short push (approx. 1s) – night attenuation
long push (approx. 5 s) – TEST (code learning)
control element – knob
for temperature setting
holes for installation
screws
Fig.1 Fig.2
Fig.3
holes for installation
screws
output terminals
power terminals
EXPLANATIONS: LIT UNLIT FLASHING
LED1 LED2 FUNCTION
empty memory, code not learned
code learned
FLASHING ALTERNATELY= code learning mode
FLASHING SIMULTANEOUSLY= code has been learned
SIMULTANEOUS LONG FLASH= code has been ERASED
relay switched
ERROR (if no signal is received from the transmitter
within approx. 6 hours, it switches to the 2-min-ON /
8-min-OFF mode). LED 2 is only fl ashing if
the relay is on, i.e. for 2 minutes.
FUNCTION BUTTON:
SHORT PRESS (about 1.5 s)
- for coding.
LONG PRESS (about 5 s)
- RESET deleting the code
from the memory (the green
and red LEDs fl ash
simultaneously).
Produktspezifikationen
Marke: | Elektrobock |
Kategorie: | Thermostaat |
Modell: | BT012 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Elektrobock BT012 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostaat Elektrobock
1 September 2024
26 August 2024
26 August 2024
17 August 2024
12 August 2024
6 August 2024
1 August 2024
1 August 2024
30 Juli 2024
25 Juli 2024
Bedienungsanleitung Thermostaat
- Thermostaat Basetech
- Thermostaat SilverCrest
- Thermostaat Cotech
- Thermostaat Bosch
- Thermostaat AEG
- Thermostaat Siemens
- Thermostaat ATAG
- Thermostaat EMOS
- Thermostaat Gira
- Thermostaat HomeMatic
- Thermostaat Renkforce
- Thermostaat Schneider
- Thermostaat GE
- Thermostaat King
- Thermostaat Avidsen
- Thermostaat Elro
- Thermostaat Tesla
- Thermostaat Max
- Thermostaat Vaillant
- Thermostaat Honeywell
- Thermostaat Remko
- Thermostaat Junkers
- Thermostaat De Dietrich
- Thermostaat Netatmo
- Thermostaat Theben
- Thermostaat Tado
- Thermostaat Remeha
- Thermostaat Saunier Duval
- Thermostaat Truma
- Thermostaat Viessmann
- Thermostaat Xavax
- Thermostaat Hager
- Thermostaat Dimplex
- Thermostaat Buderus
- Thermostaat JUNG
- Thermostaat Hunter
- Thermostaat Wolf
- Thermostaat Nest
- Thermostaat Magnum
- Thermostaat HQ
- Thermostaat Itho Daalderop
- Thermostaat Carrier
- Thermostaat Tylö
- Thermostaat Busch-Jaeger
- Thermostaat Sygonix
- Thermostaat Orbis
- Thermostaat Econo-heat
- Thermostaat EQ-3
- Thermostaat Eberle
- Thermostaat Bulex
- Thermostaat Danfoss
- Thermostaat Delta Dore
- Thermostaat Fantini Cosmi
- Thermostaat Grässlin
- Thermostaat Oventrop
- Thermostaat Salus
- Thermostaat Seitron
- Thermostaat Mikoterm
- Thermostaat Ferroli
- Thermostaat Daikin
- Thermostaat Vemer
- Thermostaat EnerGenie
- Thermostaat Oregon Scientific
- Thermostaat Finder
- Thermostaat Homematic IP
- Thermostaat EQ3
- Thermostaat Elgato
- Thermostaat Elco
- Thermostaat Drayton
- Thermostaat Drayton Erie
- Thermostaat EasyTemp
- Thermostaat Eliwell
- Thermostaat Emerson
- Thermostaat Emmeti
- Thermostaat Enda
- Thermostaat Eneco
- Thermostaat Eqiva
- Thermostaat Essent
- Thermostaat Eurotronic
- Thermostaat Extraflame
- Thermostaat Frico
- Thermostaat Helios (Amfra)
- Thermostaat Hornbach
- Thermostaat Hugo Muller
- Thermostaat ICY
- Thermostaat IR-V
- Thermostaat Itho
- Thermostaat Johnson Control
- Thermostaat Niko
- Thermostaat Nobo
- Thermostaat Otio
- Thermostaat Plieger
- Thermostaat Plugwise
- Thermostaat Radson
- Thermostaat THERMAFLEX
- Thermostaat Thermy
- Thermostaat Hive
- Thermostaat UPM
- Thermostaat VDH
- Thermostaat Watts
- Thermostaat Worcester-Bosch
- Thermostaat Heatit
- Thermostaat POER
- Thermostaat H-Tronic
- Thermostaat PECO
- Thermostaat Emko
- Thermostaat Fibaro
- Thermostaat Heatmiser
- Thermostaat Crestron
- Thermostaat ORNO
- Thermostaat Optima
- Thermostaat HomePilot
- Thermostaat Ouellet
- Thermostaat Maico
- Thermostaat Tellur
- Thermostaat STI
- Thermostaat Tru Components
- Thermostaat Qubino
- Thermostaat Amfra
- Thermostaat Aube
- Thermostaat AWB
- Thermostaat Wattio
- Thermostaat Brink
- Thermostaat 2Heat
- Thermostaat Bryant
- Thermostaat Veria
- Thermostaat Innogy
- Thermostaat ELKO
- Thermostaat MundoControl
- Thermostaat Bearware
- Thermostaat GENERAL Life
Neueste Bedienungsanleitung für -Kategorien-
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
15 September 2024
13 September 2024
13 September 2024
13 September 2024