Electrolux EWE361KA-DWP6 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Electrolux EWE361KA-DWP6 (3 Seiten) in der Kategorie Durchlauferhitzer und Boiler. Dieser Bedienungsanleitung war für 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
EN ELECTRIC WATER HEATER USER MANUAL
1. PARTS IDENTIFICATION
1. Front Cover
2. LED Indicators
i) Earth LED Indicator
ii) Power/ELCB LED Indicator
3. Test / Reset Button
4. Face Panel
5. Pump Button*
6. Temperature Control Knob
7. 3 in 1 Stop Valve
i) Stop Valve Lever
ii) Flow Regulator Valve Adjustment
iii) Built-in-Filter
8. Mesh Filter
9. Rail Support
10.
Handshower
11. Adjustable Shower Holder
12. Slider Rail
13. PVC Hose
14. Soap Tray
15. Heater Base
16. Terminal Block
17. Thermostat (Double-Action)
18. Heater Tank
19. PCB Board (Test & Reset)
20. VR Board
21. Main/ELCB Board**
22. Water Outlet Connection
23. AC Pump*
24. TRIAC
25. Reed Switch Assy***
26. Water Inlet Connection***
27. SMPS PCB Board
28. D.C. Silent Pump*
29. Rating Label
30. Pump Board
31 Shower Bracket Holder
2.
SAFETY INFORMATION
2.1 Products manufactured by Electrolux are safe
provided they are installed, used and maintained
in good working order in accordance with our
instructions and recommendations. Always refer
to this manual if you have any doubt.
2.2 The Electric Water Heater must be earthed.
Improper grounding could cause electrical shock.
2.3 If any of the following conditions occur as
shown below, immediately switch off the power
supply and contact the Electrolux Consumer
2.6 When the Electric Water Heater is
used by someone such as child, elderly
person, sick person and physically
handicapped person, the person
concerned is kindly requested to pay
attention and check the shower
temperature by hand from time to time.
2.7 During lightning/thunder, switch off the power
supply to the Electric Water Heater in advance to protect
the Electric Water Heater against possible damage.
2.8 The earth continuity conductor of the electrical
installation must be effectively connected to all
exposed metal parts of other appliances and
services in the room, which in the Electric Water
Heater is to be installed to conform to local
regulations and ensure proper earthing/grounding
for ELCB to be effective.
NOTE : When removing the Electric Water Heater
from package, a small amount of water may be
found inside. This is normal as the Electric Water
Heater is tested during manufacturing process.
WARNING !
.
.
.
.
.
If the Electric Water Heater begins to make an
odd noise, smell or smoke.
If ELCB trips and Electric Water Heater Indicator
does not light up.
Water temperature cannot be controlled.
If the Electric Water Heater shows signs of a
distinct change in performance.
If water leaks from inside.
2.10 Installation must be carried out by a
quali ed personnel and in compliance local 
2.11 This Electric Water Heater must be
permanently connected to the direct main line
supply. A plug and socket is not recommended
to be used.
2.12 For the correct size of wire conductor
corresponding to different electrical loadings,
2.13 This Electric Water Heater operates at a
minimum water flow rate of 2.0 litre/min
and maximum working
2.14 The Electric Water Heater will not function
if there is insuf cient water ow (min 2.0 litre/minfi fl
2.15
The built-in ELCB will automatically cut off
the power supply in case there is a current
2.16
The thermostat will automatically cut off the
power supply if it has sensed an abnormal rise in
water temperature.
CAUTION !
authority regulations.
please refer to Table 1.
pressure of 6 bars.
For direct connection from the water tank, the
Electric Water Heater must have an installation
minimum 1.0m below the water tank.
leakage over 15mA.
Care Center. Never attempt to repair the Electric
Water Heater yourself:
2.5 For Pump Model, it is highly recommended
to connect the Water Inlet Connection to tank
storage supply, otherwise it may cause damage
to the Pump Motor.
User is advised to test and adjust the
water temperature before using.
2.9 WARNING : Metallic / chromed hose and
conductive control valve shall not be used.
3. ELECTRIC WATER HEATER UNIT INSTALLATION
3.1 Select a suitable position in the bathroom.
3.2 Remove the screw (A) at the bottom of the
Electric Water Heater
. (Fig. 2)
3.3 Remove the Front Cover from the bottom and then lift up the front cover.
3.4 Mark 3 Screw points of the Heater Base on the wall. The
Electric Water Heater
position should be
1.5m above the bathroom floor. (Fig. 2)
3.6 Use 6mm diameter drill and make the wall plug holes in depth of 34mm ,for mount the Electric
Water Heater.
3.7 Insert the wall plugs and mount the
Electric Water Heater
firmly in position with the screws provided.
3.8 Insert the Shower Holder and Soap Tray into the Slider Rail.
3.9 Insert the Rail Bracket to both end of the Slider Rail Bar.
3.10 Remove the cap from the Rail Bracket and screw the Bracket to marked position.
Replace the cap. (Fig. 3)
connect to
water outlet
connection
ELECTRIC WATER HEATER
UNIT INSTALLATION DIAGRAM
Fig. 2
Screw
A
3 in 1
stop valve
inlet
Wall
285.5mm
Washer
connect to
water inlet
connection
Min.
80 mm
150mm
O FF
4. PLUMBING PROCEDURE
CAUTION!
IMPORTANT
This Electric Water Heater is a single point
system and the “Water Outlet” can only be
fitted to the Hose and Handshower set
provided. MUST NOT TO CONNECT
CONTROL VALVE OR FITTING CAN BE
FITTED TO THE WATER OUTLET.
WARNING!
5.
ELECTRICAL INSTALLATION
WARNING!
PROCEDURE :
5.7 Connect the cable as following: (Fig. 5)
BROWN or RED --LIVE (L)
BLUE or BLACK --NEUTRAL (N)
GREEN or GREEN/YELLOW --EARTH ( )
5.8 Clamp the cable to the correct position.
Technician need to confirm the wire before
installation.
CHECK IF THE WIRING CONNECTION IS
CORRECT and replace the cover.
5.9 When putting back the Front Cover,
please take note of the procedure shown below :
-Ensure the position is correct, turn the
Temperature Control Knob Insert to OFF
position as shown in Fig.A (At the Heater Base)
-Install the Front Cover,turn the Temperature
Control Knob to OFF position to align with the
VR shaft as shown in Fig.B (At the Front Cover)
5.10 Fix the Temperature Control Knob and
screw ‘A’ (Fig. 2).
5.1 This Electric Water Heater must be
earthed. Improper grounding could cause
electrical shock.
5.2 Remember to SWITCH OFF the power
supply before carrying out any electrical work.
5.3 Refer to TABLE 1 for the correct cable size.
5.4 Use double insulation cable of over 2.5mm²
for 2.4kW, 3.5kW 3.8kW, 4.5kW 4.8kW models
and 4mm² for 3.6kW and 6.0kW model.
5.5 Lead the power cable from MCB to a
“ON/OFF’’ double pole Linked Switch having a
contact separation of at least 3mm in all poles
outside the bathroom, then lead a cable to the
terminal block inside the Electric Water Heater.
(Fig. 4)
5.6 Insert the wall embedded cable through
Side Entry ‘A’ by cutting a hole at the source
cord rubber holder and lead the cable to
Cable Bracket ‘B’. (Fig. 6)
Always KEEP the water supply to the Electric Water
Heater free from mud and dirt at all time during usage.
4.1 Connect the 3 in 1 Stop Valve to the Water
Inlet with washer. Use correct tools to tighten
and be careful not to over tighten and damage
the plastic nut.
4.2 Connect the incoming water piping to the 3 in
1 Stop Valve (1/2” BSP).
Make sure to put the Mesh Filter between 3
in 1 Stop Valve and incoming water piping.
4.3
If in any case, the 3 in 1 Stop Valve is not use or
omitted, make sure to put the Mesh Filter
between the Electric Water Heater inlet pipe
and incoming water pipe.
4.4 Turn on the water mains to drain out all plumbing
dirts before connecting the water supply to the
Electric Water Heater, the water supply to the
Electric Water Heater must be free from mud and
dirt.
4.6 Hook the Handshower to the Slider Rail
Shower Holder and adjust to your ideal position.
4.7 Check if any water leakage.
4.8 Do not use sealing tape during piping
installation.
THE HEATER TANK MUST BE FILLED UP WITH
WATER BEFORE TURNING ON THE POWER
SUPPLY TO PREVENT ANY DRY BURNT DAMAGE
TO THE HEATING ELEMENT.
4.5 Connect the Hose and Handshower to the
outlet of Electric Water Heater, be sure to put in the
Washer in between the connection. (Fig. 2)
4.10 DO NOT APPLY PLUMBING CEMENT ON
CONNECTION. WHENEVER NECESSARY, USE
ONLY THREAD OR SEALING TAPE.
4.9 THE WATER INLET AND OUTLET MUST BE
INSTALLED CORRECTLY, OTHERWISE ELECTRIC
WATER HEATER WILL NOT FUNCTION.
5. ELECTRICAL INSTALLATION (CONT’D)
6. TABLE 1 - CABLE SIZE TABLE
Power Current
(kW) (A)
220V ~
50/60 Hz
Conductor Size (csa)
mm Conduit Cable Flexible Cable
On/ Off Fuse /
Switch (A) MCB (A)
2.4 10.9 2.5 7 / 0.67mm 50 / 0.25 mm 20 20
3.5 15.9 2.5 7 / 0.67mm 50 / 0.25 mm 20 20
4.5 20.5 2.5 7 / 0.67mm 50 / 0.25 mm 32 32
6.0 27.3 4.0 7 / 0.85mm 56 / 0.30 mm 32 32
2
Voltage
(AC)
3.6 15.0 4.0 7 / 0.85mm 56 / 0.30 mm 20 20
240V ~
50/60 Hz
(Malaysia Model)
METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER
Cable
Fig. 4
Brown or Red = Live (L)
Blue or Black = Neutral (N)
Green or Green/ Yellow = Earth ( )
Fig. 5
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
ON/OFF Double Pole Switch
Double PVC cable
NOTE:
Refer to TABLE 1 for electrical loading and
correct size of wire conductor
A
B
Fig. 6
Front CoverFig A Fig B
O FF
Position
this Way
O FF
Position
this Way
1 2
3 4 5
(2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW model
only)
/ 2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW model
only) to trigger the flow switch.
REV 1
Fig. 3a
(Thailand, Indonesia, Philippines,
and Malaysia pump model)
SHOWER SET INSTALLATION DIAGRAM
Fig. 3b
(Malaysia standard model)
SHOWER SET INSTALLATION DIAGRAM
Cap
Screw
Rail Bracket
Adjustable
Shower
Holder
Wall Plug
Slider
Rail Bar Flexible Angle
Adjustment
Flexible
Hose
Hand
Shower
PVC Hose
Shower
Screw
Shower
Holder
Cover
Shower
Holder
Cover
Head
SLIDER BAR ACCESSORIES
(Single Spray)
BRACKET ACCESSORIES
(Single Spray)
3.5. : Mark 2 screw points of the Slider Rail beside the Electric Water Heater. Slider Bar Accessories
It is recommended that the top of the portion is in level with the top of Electric Water Heater. (Fig. 3 & 3a)
Bracket Accessories: Open the Shower Holder cover, mark 2 screw point of the Shower Holder beside
the Electric Water Heater. It is recommended that the top of the portion is in level the top Electric
Water Heater. After screw the Shower Holder, put back the shower holder cover. (Fig. 3b)
EWE361KA-DWG6
EWE381KX-DWG6
EWE481KX-DWG6
EWE601KX1DWG6
EWE351KX-DWX6
EWE361KA-DWP6
EWE451KX-DWB2
EWE241KX-DWB6
EWE351KX-DWB6
EWE451KX-DWB6
EWE361KA-DWB6
EWE361KX-DWB5
EWE361KX-DWX5
3.8 17.3 2.5 7 / 0.67mm 50 / 0.25 mm 20 20
4.8 21.8 2.5 7 / 0.67mm 50 / 0.25 mm 32 32
2.4 If the Red (POWER) Indicator does not go off
when you turn off the water, switch OFF the
mains supply and contact Electrolux Consumer
Care Centre for repair service.Special skill is
required for repairing.
NEVER try to repair the unit by yourself.
15
16
18
19
22
21
23
24
25
26
FFO
7
8
27
24
25
26
FFO
7
8
28
No Pump model
24
25
26
FFO
7
8
AC Pump model DC Pump model
Fig. 1
15
16
18
19
22
20
21
17 17
15
16
18
19
17
9
10
12
13
14
11
FFO
7
8
1
5
4
29
30
22
21
30
6
*
*
*
3
2
* For Pump Model only
** Pump Model VR Board & Main/ELCB Board combine.
10
31
13
9
10
12
13
11
Slider Bar Accessories
(Single Spray)
Bracket Accessories
(Single Spray)
Slider Bar Accessories
* ** * **
** **
Fig. 3 (Vietnam only)
SHOWER SET INSTALLATION DIAGRAM
Flexible
Angle
Adjustment
5 Spray
Patterns
Selection
Hand
Shower
Flexible
Hose
Soap
Tray
Slider
Rail Bar
Adjustable
Shower
Holder
Screw
Wall
Plug
Mounting
Terminal
connect to
water outlet
connection
Rail bracket
cap
Hexagon tool
(Tighten plastic nut before close cap)
Plastic nut
Fig 3C
RAIL BRACKET COVER & CAP DISMANTLE STEPS FOR SLIDER BAR ACCESSORIES
1RAIL BRACKET 2
OPEN THE RAIL
BRACKET COVER
BY TURNING ANTI
CLOCKWISE & USING
SCREW DRIVER TO OPEN
THE CAP
3RAIL BRACKET
COVER COME-OUT
Fig 1.
Slide Bar Accessories (Vietnam only)
Slide Bar Accessories (Single Spray – Thailand, Indonesia, Philippines, and Malaysia pump model)
Bracket Accessories (Single Spray – Malaysia standard model)
***
***
*** No pump Model 4.8kW & 6.0kW using Flow Sensor Assembly.
7. TEST RUN
7.1 Turn on the water supply and 3 in 1
Stop Valve, the water will flow through the
Handshower.
7.2 Switch on the power supply. The 3
LED Indicator light shall run ON/OFF 3
times in sequences to indicate the set are
self checking.
If the
Electric Water Heater
is not earthed
properly, the Earth Led indicator light will
OFF, during usage or standby. Earth Led
indicator light also OFF if Live & Neutral
reverse connection.
7.4 The
Electric Water Heater
might not be
hot enough even at the ‘MAX’ position if
incoming water supply from the mains is too
cold or the pressure of water is too high. In
this case, you may adjust the 3 in 1 Stop Valve
to reduce the water inflow in order to get the
desired showering temperature.
7.5 Check the Built-in ELCB as following:
- Press the “TEST” Button, the Built-in ELCB
should trip and cut off the power supply,
ELCB and Power Indicators should light off.
-Press the “RESET” Button, the 3 LED
Indicator light shall run ON/OFF 3 times in
sequences to indicate self checking as in 7.2
above and the
Electric Water Heater
should
resume normal function, the Green LED
Indicator should light on. If procedures stated
above prevailed, the ELCB is functioning in
normal condition.
7.6 The height and direction of Shower
Holder are adjustable by releasing the shower
holder knob clockwise and anticlockwise.
7.7 Move the Handshower to the desired
angle. A ratchet mechanism in the Shower
Holder will hold the Handshower in selected
position.
7.8 It is unnecessary to turn the Temperature
Control Knob to “OFF” position when the
Instant Hot Shower is not in use.
7.9 Switch OFF the power supply after shower.
(Recommended flow rate of below 6litre/min)
8. HANDSHOWER SPRAY
This Innovative adjustable Handshower has 5 different spray patterns (STANDARD, JUMBO, SOOTHE, MIX
and MASSAGE. The patterns are described as following:
9. MAINTENANCE
Fig. 7 (Vietnam)
Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
Fig. 8 Fig. 9
FILTER UNIT CLEANING
CLOSE
OPEN
INTERNAL
STRAINER
OPEN CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
9.1 TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended test at
least once a month)
9.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent
blockage (Fig. 8) . Remove the Built-in Filter by
turning its cap anticlockwise. Whenever need
Read the section ‘ SAFETY INFORMATION ’ first.
WARNING!
9.3 If the Red (POWER) Indicator does not
go off when you press the ELCB Test Button,
switch OFF the mains supply and contact
Electrolux Consumer Care Centre for repair
service. Special skill is required for repairing.
NEVER try to repair the unit by yourself.
9.4 CLEANING PRECAUTION !
Do not use thinner,alcohol,petrol or any other
organic solutions to clean the set. Use only
damped cloth with mild detergent.
flush the internal stainer with water to remove
any trapped sediments. Whenever fixing back
the Built-In Filter, beware of the alignment of
Internal Strainer. Use the protruded guideline
within Stop Valve to position the Internal
Strainer.
10.
WIRING DIAGRAM
WIRING DIAGRAM -WITH ELCB, AC PUMP DPDT MODEL
LIVE
NEUTRAL
TRIAC
Relay 1 L out
Relay 2 N out
(N
in
)
(L
in
)
Auto-Reset M anual-Reset*
Power Su pply
220/230/240 V~a.c.
Double Action Thermostat
T2
G
Electronic
ELCB,15mA
Sensitivity
Rese t
Test
Heat Controler
On/Off Switch
Power On/Off
Temperature Control
Pump Motor
EP Model
PUMP
WIRING DIAGRAM -WITH ELCB, NO PUMP DPDT MODEL
LIVE
NEUTRAL
Power On/Off
T rol emperature Cont
TRIAC
Lout
Nout
(N
in
)
(L
in
)
Auto-Reset * Manual-Reset
Power Su pply
220/230 /240 V~a .c.
Double Action Thermostat
Electronic
ELCB,15mA
Sensitivity
Rese t
Test
T2
G
Heat er Control
On/Off Switch
Relay 1
Relay 2
WIRING DIAGRAM -WITH ELCB, DC PUMP DPDT MODEL
LIVE
NEUTRAL
TRIAC
Relay 1 L out
Relay 2 N out (N
in
)
(L
in
)
Auto-Reset * M anual-Reset
Power Su pply
220/230/240 V~a.c.
Double Ac tion Thermostat
T2
G
Electronic
ELCB,15mA
Sensitivity
Rese t
Test
Heat er Control
On/Off Swit ch
Po r fwe On/Of
Temperature Control
SMPS PCB
ASSY
Silent Pump
WIRING DIAGRAM -WITH ELCB, NO PUMP DPDT MODEL (FOR VIETNAM MODELS ONLY)
LIVE
NEUTRAL
Power On/Of
Temperature Control
Lout
Nout
(N
in
)
(L
in
)
Auto-Reset * Manual-Reset
220/230 /240 V~a .c.
Double Action Thermostat
Electronic
ELCB,15mA
Sensitivity
Rese t
Test
T2
G
Heat ing Eleme nt A
Heat ing Eleme nt B
Heater Control
On/Off Switch
TRIAC
Relay 1
Relay 2
Relay 3
Power S upply
11.
ELECTRICAL SPECIFICATION
Note : The specification, actual product’s cosmetic design and accessories parts shown are
correct at the time of printing and may be subjected to change without prior notice.
2.5 kg AC Pump Model
2.0 kg DC Pump Model
1.5 kg No Pump Model / 1.7 kg No Pump Model (6kW)
ELECTRONIC POWER CONTROLTYPE
ELECTRICAL LOADING
Min. WATER FLOW RATE
WATER CONNECTION
DIMENSIONS
NET WEIGHT
1/2” BSP SINGLE POINT SYSTEM
220 (W) X 401 (H) X 90 (T) mm
6.0 Bar (0.6 MPa ; 87.02 psi)
Max. INLET WATER PRESSURE
Min. INLET WATER PRESSURE
0.1 Bar (10 kPa ; 1.45 psi)
* Manual Reset (90° C Thermostat)Thermostat
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced once permanently tripped.
2.4kW TO 6.0kW 220V-240V a.c. 50/60Hz
10. WIRING DIAGRAM (CON’D)
WIRING DIAGRAM -WITH ELCB, AC PUMP DPDT MODEL (FOR VIETNAM MODELS ONLY)
LIVE
NEUTRAL
TRIAC
Relay 1 L out
Relay 2 N out (N in
)
(L
in
)
Auto-Reset * M anual- Reset
Powe r Sup ply
220/230/240 V~a.c.
Double Action Thermostat
T2
G
Electronic
ELCB,15mA
Sensitivity
Res et
Test
Heater Control
On/Off Switch
Power On/Off
Temperature Control
Pump Motor
PUMP
Heat ing Elem ent A
Heat ing Elem ent B
Relay 3
WIRING DIAGRAM -WITH ELCB, DC PUMP DPDT MODEL (FOR VIETNAM MODELS ONLY)
LIVE
NEUTRAL
TRIAC
Relay 1 L out
Relay 2 N out (N
in
)
(L
in
)
Auto-Reset * M anual- Reset
Powe r Sup ply
220/230/240 V~a.c.
Double Action Thermostat
T2
G
Electronic
ELCB,15mA
Sensitivity
Res et
Test
Heater Control
On/Off Switch
f
Power On/Off
Temperature Control
Heat ing Elem ent A
Heat ing Elem ent B
Relay 3
SMPS PCB
ASSY
Silent Pump
2 Litre / min (2.2 ℓ/Min for 4.8kW & 2.5 ℓ/min for 6.0kW model only)
CONSUMER CARE
Indonesia
Hotline service: 08041119999
PT. Electrolux Indonesia
Electrolux Building
Jl.Abdul Muis No.34, Petojo Selatan,
Gambir Jakarta Pusat 10160
Email:customercare@electrolux.co.id
SMS & WA : 0812.8088.8863
Malaysia
Consumer Care Center Tel: 1300-88-11-22
Electrolux Home Appliances Sdn. Bhd.
Corporate Office Address: Unit T2-7, 7th Floor, Tower 2 ,
Jaya33 Hyperoffice, No. 3, Jalan Semangat, Seksyen 13,
46100 Petaling Jaya, Selangor
Office Tel : (+60 3) 7843 5999
Office Fax : (+60 3) 7955 5511
Consumer Care Center Address: Lot C6, No. 28,
Jalan 15/22, Taman Perindustrain Tiong Nam,
40200 Shah Alam, Selangor
Consumer Care Center Fax : (+60 3) 5524 2521
Email : malaysia.customercare@electrolux.com
Philippines
Consumer Care Center Toll Free : 1-800-10-845-CARE 2273
Consumer Care Hotline : (+63 2) 845 CARE 2273
Electrolux Philippines, Inc.
10th Floor. W5th Avenue Building
5th Avenue Corner 32nd Street
Bonifacio Global City,
Taguig Philippines 1634
Trunkline: +63 2 737- 4756
Website : www.electrolux.com.ph
Email : wecare@electrolux.com
Singapore
Consumer Care Center Tel: (+65) 6727 3699
Electrolux S.E.A. Pte Ltd.
1 Fusionopolis Place,
#07-10 Galaxis, West Lobby
Singapore 138522.
Office Fax : (+65) 6727 3611
Email : customer-care.sin@electrolux.com
Thailand
Consumer Care Tel : (+66 2) 725 9000
Electrolux Thailand Co., Ltd.
Electrolux Building 14th Floor
1910 New Phetchaburi Road,
Bangkapi, Huai Khwang, Bangkok 10310
Office Tel : (+66 2) 7259100
Office Fax : (+66 2) 7259299
Email : customercarethai@electrolux.com
Vietnam
Consumer Care Center Toll Free : 1800-58-88-99
Tel : (+84 8) 3910 5465
Electrolux Vietnam Ltd.
Floor 9th, A&B Tower
76 Le Lai street - Ben Thanh Ward - District 1
Ho Chi Minh City ,Vietnam
Office Tel : (+84 8) 3910 5465
Office Fax : (+84 8) 3910 5470
Email : vncare@electrolux.com
Hongkong
Tel: (+852) 8203 0298
Dah Chong Hong, Ltd. - Service Centre
8/F., Yee Lim Godown Block C
2-28 Kwai Lok Street, Kwai Chung, N.T.
6 7 8
9 10
7.10 For Pump model:
The pump will auto ON when power ON and
3 in 1 stop valve open (and there is water supply)
flow rate.
7.11 Booster Pump Function:
After incoming power supply is ON, and water
supply flow through 3 in 1 stop valve while open
position but the water flow rate is not sufficient to
activate the flow sensor, Booster Pump Function
can be useful to help to increase the incoming water
Press the pump button to activate the booster
pump function. The booster pump function will be ON to
increase the incoming water flow rate. While the Booster
Pump Function is working and the incoming water flow
rate can be maintained above flow sensor activation level,
the Electric Water Heater will be resumed working
continuously as normally. If the incoming flow rate can
not be maintained above flow sensor activation level,
the Booster Pump Function will be auto OFF and the
Electric Water Heater will not be able to function normally
due to incoming flow rate is too low. (Advisable to avoid
applying Booster Pump Function to increase the incoming
water flow rate more than 3 times of each showering).
.Fig 7a (Thailand, Indonesia,
Philippines, and Malaysia)
STANDARD SINGLE SPRAY
Pump Butt on
Pump Butt on
Pump Butt on
Pump Butt on
7.3 Turn the Temperature Control Knob to
‘ON’, the Red indicator light (HEATER POWER)
will turn on, (ELCB/Power Led indication are
combine Led indicator light- ELCB is GREEN
& Power is RED) hot water will flow out within
a few seconds. The more Temperature Control
Knob being turned in clockwise direction, the
hotter is the water.
Turn on the power supply and water supply , both
Red (HEATER) and Green (ELCB) Indicators will
light up if the Temperature Control Knob is in ‘ON’
position. Press the ELCB Test Button, both
HEATER and ELCB Indicators should go off.
Press the Reset Button to resume the power
supply.
STANDARD SPRAY SOOTHE SPRAY JUMBO SPRAY MIX SPRAY MASSAGE SPRAY
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with
it decades of professional experience and innovation. In genious and stylish, it has been
designed with you in mind. So whenever you use it, you can be safe in knowledge that
you’ll get great results every time. Welcome to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONSUMER CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number.
(Right side of unit).
Warning/ Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
3.6kW 240V a.c. 50/60Hz (Malaysia Model Only)
*No pump Model 4.8kW & 6.0kW using Flow Sensor Assembly.
*Flow Sensor Assembl y.
l


Produktspezifikationen

Marke: Electrolux
Kategorie: Durchlauferhitzer und Boiler
Modell: EWE361KA-DWP6

Brauchst du Hilfe?

Wenn Sie Hilfe mit Electrolux EWE361KA-DWP6 benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Durchlauferhitzer und Boiler Electrolux

Bedienungsanleitung Durchlauferhitzer und Boiler

Neueste Bedienungsanleitung fĂźr -Kategorien-