9SX700
9SX1000
9SX1000G
9SX1500
9SX1500G
9SX2000
9SX2000G
9SX3000
9SX3000G
9SX3000GL
9SX3000HW
9SXEBM36
9SXEBM48
9SXEBM96
Installation
and user manual
Copyright © 2018 EATON
All rights reserved.
614-20623-00_EN
9SX 0-3 KVA AMER
Page 2 614-20623-00 - 9SX 0-3 KVA AMER_EN
SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
The 9SX models that are covered in this manual are intended for installation in an environment within
0 to 40 °C, free of conductive contaminant.
Please check section "6.1 Equipment care", page 30, for additional information.
Special symbols
The following are examples of symbols used on the UPS or accessories to alert you to important
information:
RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
Important instructions that must always be followed.
Do not discard the UPS or the UPS batteries in the trash.
This product contains sealed lead acid batteries and must be disposed as it's explain in this manual.
For more information, contact your local recycling/reuse or hazardous waste center.
This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the
trash.
For proper disposal, contact your local recycling/reuse or hazardous waste center.
Information, advice, help.
Refer to the user manual of UPS accessories.
SAFETY INSTRUCTIONS
Page 3
614-20623-00 - 9SX 0-3 KVA AMER_EN
SAFETY INSTRUCTIONS
Safety of persons
The system has its own power source (the battery). Consequently, the power outlets may be energized
even if the systems is disconnected from the AC power source. Dangerous voltage levels are present
within the system. It should be opened exclusively by quali ed service personnel.
The system must be properly grounded.
The battery supplied with the system contains small amounts of toxic materials.
To avoid accidents, the directives listed below must be observed:
- Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries
and the required precautions.
- When replacing batteries, replace with the same type and number of batteries or battery packs.
- Do not dispose of batteries in a re. The batteries may explode.
- Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high.
Precautions must be taken for all handling:
- Wear rubber gloves and boots.
- Do not lay tools or metal parts on top of batteries.
- Disconnect charging source prior to connecting or disconnecting battery terminals.
- Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground.
Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can
be reduced if such grounds are removed during installation and maintenance (applicable to equipment
and remote battery supplies not having a grounded supply circuit).
Product safety
The UPS connection instructions and operation described in the manual must be followed in the indicated
order.
CAUTION - To reduce the risk of re, the unit connects only to a circuit provided with 15, 20 or 30
amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code,
ANSI/NFPA 70 (US installations only).
Check that the indications on the rating plate correspond to your AC powered system and to the actual
electrical consumption of all the equipment to be connected to the system.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily
accessible.
Never install the system near liquids or in an excessively damp environment.
Never let a foreign body penetrate inside the system.
Never block the ventilation grates of the system.
Never expose the system to direct sunlight or source of heat.
If the system must be stored prior to installation, storage must be in a dry place.
The admissible storage temperature range is -25 ºC to +55 ºC without batteries, 0 ºC to +40 ºC with batteries.
The system is not for use in a computer room AS DEFINED IN the standard for the Protection of Information
Technology Equipment, ANSI/NFPA 75 (US installations only).


Produktspezifikationen

Marke: Eaton
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: 9SXEBM240
Breite: 130 mm
Tiefe: 440 mm
Gewicht: 68000 g
Produktfarbe: Schwarz
Höhe: 645 mm
Anzahl unterstützter Akkus/Batterien: 20
Rack-Einbau: Ja
Akku-/Batteriespannung: 12 V
Batteriekapazität: 7 Ah
Formfaktor: Rackmount/Tower
Rack-Kapazität: 3U

Brauchst du Hilfe?

Wenn Sie Hilfe mit Eaton 9SXEBM240 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem Eaton

Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem

Neueste Bedienungsanleitung für -Kategorien-