Dimplex PLX1500NC Bedienungsanleitung

Dimplex Heizung PLX1500NC

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Dimplex PLX1500NC (4 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Installation and Operating Instructions
INDPUKP5RG Issue 6
PLX Panel Convector Heaters
Dimensions
(millimetres)
Model s( )
PLX 500/NC/TI 500 450 108 116
PLX 750/NC/TI 750 620 108 286
PLX 1000/NC/TI 1000 620 108 286
PLX 1250/NC/TI 1250 688 108 354
PLX 1500/NC/TI 1500 688 108 354
PLX 2000/NC/TI/TX 2000 860 108 526
PLX 3000/TI/TX 3000 860 143 526
Important Safety Advice
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of re, electrical shock, and
injury to persons, including the following:
IMPORTANT The wall bracket supplied with
the appliance must be used.
WARNING Do not use this heater in the
immediate surroundings of a bath, a shower
or a swimming pool.
IMPORTANT If the heater is installed in a
room containing a bath or shower, it must be
so installed that switches and other controls
cannot be touched by a person using a bath
or shower.
Do not use outdoors.
Do not locate the heater immediately below a
xed socket outlet or connection box.
WARNING: In order to avoid overheating, do
not cover the heater. Do not place material
or garments on the heater, or obstruct the
air circulation around the heater, for instance
by curtains or furniture, as this could cause
overheating and a re risk.
NEVER cover or obstruct in any way the heat
outlet slots at the top of the heater or the air
inlet slots in the base of the heater.
The heater carries the Warning symbol
indicating that it must not be covered.
CAUTION - Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vulnerable people are present.
This appliance can be used by children aged
from 8 years and above and by persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given supervision
or instruction concerning use of the appliance
in a safe way and understand the hazards
involved.
Fig. 1
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Watt A B X
150
MIN
150
MIN
150
MIN
B
430
119 215
X
X
X
X
310
150
150 min
255
A
X
Children shall not play with the appliance.
Cleaning and user maintainance shall not be
made by children without supervision.
Children of less than 3 years should be kept
away unless continuously supervised.
Children aged from 3 years and less than 8
years shall only switch on/off the appliance
provided that it has been placed or installed
in its intended normal operating position and
they have been given supervision or instruction
concerning use of the appliance in a safe
way and understand the hazards involved.
Children aged from 3 years and less than 8
years shall not plug in, regulate and clean the
appliance or perform user maintainance.
Note that due care and consideration must be
taken when using this heater in series with a
thermal control, a program controller, a timer
or any other device that switches on the heat
automatically, since a re risk exists when the
heater is accidentally covered or displaced.
If the supply cord is damaged it must be
replaced by the manufacturer or service agent
or a similarly qualied person in order to avoid
a hazard.
WARNING: Servicing and product
repairs should only be undertaken by the
manufacturers approved service agent or a
similarly qualied person, using only exact
manufacturer approved spare parts.
IMPORTANT The supply circuit to the heater
must incorporate a double pole isolating switch
having a contact separation of at least 3mm.
WARNING: PLX****NC heaters are not
equipped with a device to control the room
temperature. Do not use these heater in small
rooms when they are occupied by persons
not capable of leaving the room on their own,
unless constant supervision is provided.
Access to the controls
The controls cover (see ‘x’ in Fig. 1) on your heater has a
latch which may be locked shut if desired using a small bladed
screwdriver - see .Fig. 3
To open the cover insert the blade of the screwdriver in the
small slot and rotate a quarter of a turn clockwise to disengage
the latch. The cover may then be hinged back towards the wall
for access to the controls.
Operation - Thermostat only models
Control of Output and Temperature Fig. 4(see )
The switch marked and controls the electricity supply to the O I
heating elements. The OFF position is marked .O
The switch marked - (half heat full heat) provides a I II
choice of output as desired.
Thermostat Operation
The heater is tted with an adjustable thermostat enabling
the room temperature to be controlled by adjusting the setting
accordingly. The * setting represents a room temperature of
approximately 5°C and may be used for protection against
frost. Higher temperature settings range from 1-6 (max.)
creating a room temperature of approximately 30°C.
A neon indicator light glows when the appliance is actually
heating.
Switch on the heater and turn the thermostat knob to mark
6 opposite the indicator mark (located on centre right of the
knob - see & ), and set selector switch to full heat Fig. 4 5
output to warm the room rapidly. When the room temperature
has reached the desired level, turn the thermostat knob back
slowly until the thermostat just clicks off. The heater will then
maintain the room temperature at the chosen level, provided
that the correct size of heater has been selected for the room
to be heated.
NOTE Should your heater fail to come on when the
thermostat knob is at a low setting, this may be due to the
room temperature being higher than the thermostat setting.
General
NOTE: The PLX Convector is designed for wall mounting on
the wall brackets supplied. The wall brackets supplied with the
appliance must be used. It should only be operated when in
the upright position as shown.
All models are splashproof to IP24 standard.
Models PLX…TI are tted with a 24 hour programmable timer.
Models PLX…TX are tted with a 7 day programmable timer.
Models PLX…NC are tted with no controls, for use with
external thermostatic or programming controllers.
Before connecting the heater check that the supply voltage is
the same as that stated on the heater.
Please note that lit cigarettes, candles and oil burners,
combined with the convection effect of electric heaters
can cause soot deposits to build up on the surface directly
above and to the sides of the heater. This is not the fault
of the heater. Extensive burning of candles or smoking
in the operating environment of this product can produce
heavy discoloration within a few months of use.
Wall Mounting
IMPORTANT – The wall brackets supplied with the appliance
must be used. The heater should be positioned observing
the minimum clearances stated around the heater - see
Fig. 1.
DO NOT locate the heater immediately below a xed socket
outlet or connection box.
1. Remove wall mounting bracket from the back of
the heater by depressing the spring latch at the top
of each bracket - see .Fig. 2
2. Fix the wall bracket securely to the wall through the
four screw holes provided.
3. Present the heater to the wall bracket, and engage
lower slots in the back with bracket.
4. Raise the heater to upright position and push the
heater onto brackets to engage top latch.
Fig. 3
Fig. 4
Fig. 2
255
MIN
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent
electrician, and be in strict accordance with the current I.E.E.
regulations for Electrical Equipment in Buildings.
The heater is tted with a length of exible cable type H05VV-F
size 3 x 1.0mm2 on models PLX 500 - 2000 and size 3 x 1.5mm
2
on PLX 3000 models, for connection to the xed wiring of
the premises through a suitable connection box positioned
adjacent to the heater.
The supply circuit to the heater must incorporate a double pole
isolating switch having a contact separation of at least 3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing
conductor in the supply cord is deemed to provide the
supplementary bonding connection (see Regulation 544.2.5,
17th Edition I.E.E. Wiring Regulations).
Operation - TI and TX Timer Models
Control of Output and Temperature Fig. 5(see )
The slide switch on the timer unit controls the electricity supply
to the heating elements on TI and TX models.
The switch marked - (half heat full heat) provides a I II
choice of output as desired.
Thermostat Operation
- see above.
Using the Timer
The heater must be connected to the electricity supply for the
timer to operate. Set the timer by rotating the dial clockwise
until the correct time of day is indicated opposite the datum
mark (located at centre front of the timer - see ).Fig. 5
‘OFF’ Position
Set the timer switch to position. The timer operates but the
heater will not output any heat, as the electricity supply to the
heating elements has been disconnected.
Manual Operation
Set the timer switch to position. The heater will now
operate continuously under the control of the thermostat - see
‘Thermostat Operation above.
Automatic Operation
Set the timer switch to position. The panel will now operate
during set ‘ON’ periods under the control of the thermostat.
To set the timer’s ‘ON’ and ‘OFF’ periods:
1. Using your nger tip or the tip of a
pencil, push in as many segments as
necessary around the dial, according
to the times you don’t require heat
see Fig. 6. Each segment pushed
in switches the heater OFF for that
part of the hour. All other segments
will be ‘ON’.
2. You can select as many ‘ON’ periods as you like, within the
24-hour day. The settings will repeat every day until changed.
3. To change ‘ON’ and ‘OFF’ times, simply push in any ‘ON’
segments you wish to cancel and pull out new ‘ON’ segments
as required.
Note: On TI models each segment on the timer represents
20 mins.
TX Models
TX Models are tted with 7 day programmable timers. In all
other respects they are identical in installation and operation
to 24 hour timer operation on TI models.
1. Setting the Time
The current day and time is set by rotating the timer dial
clockwise until the correct day and time is indicated opposite
the datum mark.
2. Automatic Operation
Set the time switch to the symbol. Select the days and
11
13
12
14
Fig. 5
Fig. 6
times you require the heater to come on by pulling out the
appropriate segments. Each segment represents a 2 hour 20
minute period for the day indicated. The timer may be set to
give as many ‘ON’ periods of any length required in multiples
of 2 hours and 20 minutes. The programme will repeat itself
every 7 days until changed.
The programme may be over-ridden at any time by switching to
or and can be reinstated by switching back to setting.
Safety - Overheat protection
For your safety this appliance is tted with a thermal cut-out.
In the event that the product overheats for some reason, the
cut-out prevents excessive temperatures on the product by
cutting the power to the heater. Once the heater has cooled
down, it will reset automatically, it will continue to cycle on and
off automatically until the reason for overheating is removed.
Cleaning
Before commencing cleaning, unplug the heater and allow
it to cool. Disconnect the electricity supply to the appliance.
The outside can be cleaned by wiping it over with a soft damp
cloth and then dried. Do not use abrasive cleaning powders or
furniture polish, as this can damage the surface nish.
To release heater from the wall bracket for cleaning or
redecoration, depress latch on both brackets (see ) and Fig. 2
hinge forward.
Recycling
For electrical products sold within the European
Community.
At the end of the electrical products useful life
it should not be disposed of with household
waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when rst received or does not
function correctly contact us by email aftersales@dimplex.co.uk
or call 0844 879 3588 and we will be able to help. For ROI please
call 01 842 8222.
Do Not Return the product in the rst instance as this may delay
us providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE
WARRANTY.
Your product is guaranteed for two years from date of purchase. Within
this period we undertake to repair this product free of charge provided it
has been installed and operated in accordance with these instructions.
Should you require assistance with this product please go to www.
dimplex.co.uk and click on Customer Support or email us at
aftersales@dimplex.co.uk
Alternatively call our contact centre on 0844 879 3588 (UK only). This
is a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please call 01 842 8222.
To assist you, we will need the following information: model no and
serial no (these can be found on the product), nature of the fault and
date of purchase. Please retain your receipt as proof of purchase.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Spares can be purchased online, go to www.dimplex.co.uk/
outlet_store


Produktspezifikationen

Marke: Dimplex
Kategorie: Heizung
Modell: PLX1500NC

Brauchst du Hilfe?

Wenn Sie Hilfe mit Dimplex PLX1500NC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Dimplex

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-