Deye SUN-12K-G05 Bedienungsanleitung

Deye Ladegerät SUN-12K-G05

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Deye SUN-12K-G05 (69 Seiten) in der Kategorie Ladegerät. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/69
SUN-5K-G05
SUN-8K-G05SUN-6K-G05 SUN-7K-G05
SUN-4K-G05SUN-3K-G05
SUN-12K-G05SUN-10K-G05
User Manual
R
Grid-connected PV Inverter
1. Introduction - 02 -
…………………………………………………………
1.1 Appearance Introduction - 02 -
…………………………………………
2. Safety warnings and instructions - 04 -
………………………………………
2.1 Safety signs - 04 -
…………………………………………………………
1.2 Parts list - 03 -
…………………………………………………………
2.2 Safety instructions - 04 -
…………………………………………………
3. Operation Interface - 06 -
……………………………………………………
2.3 Notes for using - 05 -
……………………………………………………
3.2 Status Indicator - 06 -
……………………………………………………
3.1 Interface View - 06 -
……………………………………………………
3.4 LCD Display - 07 -
………………………………………………………
4. Product installation - 08 -
……………………………………………………
3.3 Buttons - 07 -
…………………………………………………………
4.1 Select installation location - 08 -
……………………………………………
5. Electrical Connection - 13 -
…………………………………………………
5.1 DC input terminal connection - 13 -
………………………………………
5.2 AC input terminal connection - 15 -
………………………………………
5.3 The connection of the ground line - 17 -
…………………………………
4.2 Inverter Installation - 10 -
…………………………………………………
- 18 -
…………………………………
5.4 Max. over current protection device
5.5 Inverter monitoring connection - 18 -
…………………………………
5.7 Configuration of Datalogger - 19 -
…………………………………………
- 19 -
5.6 Installation of datalogger …………………………………………
6. Startup and Shutdown - 20 -
…………………………………………………
6.1 Start up the inverter - 20 -
…………………………………………………
6.2 Inverter Shutdown - 20 -
…………………………………………………
- 21 -
…………………………………
7. Zero export function via energy meter
8. General Operation - 33 -
……………………………………………………
8.1 The initial interface - 36 -
………………………………………………
8.3 System param setting - 39 -
…………………………………………………
8.4 Running param set - 39 -
……………………………………………………
- 58 -
………………………………………………
9. Repair and Maintenance
- 58 -
…………………………………
10. Error information and processing
- 59 -
………………………………………………………
10.1 Error code
- 63 -
…………………………………………………………
11. Specification
8.5 Protect Param - 55 -
……………………………………………………
8.6 Comm. param set - 57 -
……………………………………………………
8.2 Submenus in the Main Menu - 37 -
………………………………………
- 31 -
………………………………
7.3 Notes while using zero export function
- 30 -
………………………………………
7.2 Use of zero-export function
- 31 -
7.4 How to browse the load power of your PV grid-tieplant on monitoring platform
- 25 -
7.1 Multiple strings and parallel connection meters …………………
6.3 Anti-PID Function(option) - 20 -
…………………………………………
Photovoltaic Grid-connected System
Applica�on of inverter in photovoltaic power system
Inverter MeteringPV array Power grid
Family load
Read the manual and other related documents before performing any opera�on on the inverter.
Documents must be stored carefully and be available at all �mes. Contents may be periodically
updated or revised due to product development. The informa�on in this manual is subject to
change without no�ce.The latest manual can be acquired via service@deye.com.cn .
- 01 -
About This Manual
The manual mainly describes the product informa�on, guidelines for installa�on, opera�on and
maintenance. The manual cannot include complete informa�on about the photovoltaic (PV) system.
How to Use This Manual
- 02 -
1.1 Appearance Introduc�on
1. Introduc�on






- 03 -
1.2 Parts list
Please check the following table, to see whether all the parts are included in the package
Wall moun�ng bracket x1
Moun�ng stainless steel
screws M4×12
x5
Grid-�ed PV String Inverter
x1
DC+/DC- Plug connectors
including metal terminal
xN
Stainless steel an�-collision
bolt M6×60
x4
AC power connectors x1
User
manual
User manual x1 Datalogger (op�onal) x1 Meter(op�onal)
x 1
Thre e-Phase Smart M eter
SET ESC
*Sensor Clamp(op�onal)
x 3
2. Safety warnings and instruc�ons
2.1 Safety signs
2.2 Safety instruc�ons
Improper use may result in poten�al electric shock hazards or burns. This manual contains
important instruc�ons that should be followed during installa�on and maintenance. Please
read these instruc�ons carefully before use and keep them for future reference.
Safety symbols used in this manual, which highlight poten�al safety risks and important safety
informa�on, are listed as follows:
Shock Hazard:
Cau�on, risk of electric shock symbol indicates important safety instruc�ons,
which if not correctly followed, could result in electric shock.
High Temperature Hazard:
Cau�on, hot surface symbol indicates safety instruc�ons, which if not correctly
followed, could result in burns.
Safety Hint:
Note symbol indicates important safety instruc�ons, which if not correctly
followed, could result in some damage or the destruc�on of the inverter.
Warning:
Warning symbol indicates important safety instruc�ons, which if not correctly
followed, could result in serious injury or death.
Shock Hazard:
Prohibit disassembling inverter case, there exis�ng shock hazard, which may
cause serious injury or death, please ask qualified person to repair.
Warning:
Electrical installa�on of the inverter must conform to the safety opera�on rules
of the country or local area.
Warning:
Inverter adopts non-isolated topology structure, hence must insure DC input and
AC output are electrical isolated before opera�ng the inverter.
- 04 -
- 05 -
2.3 Notes for using







 






 

 



Shock Hazard:


Shock Hazard:


High Temperature Hazard:
 

- 06 -
3.2 Status Indicator
3. Opera�on Interface
Pic 3.1 Front panel display
3.1 Interface View
ACDC AlarmNormal
There are four LED status indicator lights in the front panel of the inverter. Please see table 3.1
for details.
Explanaon
Inverter detects DC input
Low DC input voltage
Grid Connected
Grid Unavailable
Under normal opera�ng
Stop opera�ng
Detected faults or report faults
Under normal opera�ng
Indicator status
DC
AC
NORMAL
ALARM
on
off
on
off
on
off
on
off
Table 3.1 Status indicator lights
- 07 -
3.3 Bu�ons
3.4 LCD Display









  Up
- 08 -
4.1 Select installa�on loca�on
4. Product installa�on
To select a loca�on for the inverter, the following criteria should be considered:
WARNING: Risk of fire
● Do not install the inverter in areas containing highly flammable materials or gases.
● Do not install the inverter in poten�ally explosive atmospheres.
● Do not install in small closed spaces where air can not circulate freely. To avoid overhea�ng,
always make sure the flow of air around the inverter is not blocked.
● Exposure to direct sunlight will increase the opera�onal temperature of the inverter and
may cause output power limi�ng. It is recommended that inverter installed to avoid direct
sunlight or raining.
● To avoid overhea�ng ambient air temperature must be considered when choosing the
inverter installa�on loca�on. It is recommended that using a sun shade minimizing direct
sunlight when the ambient air temperature around the unit exceeds 100°F/40 .
Pic 4.1 Recommended installa�on place


Produktspezifikationen

Marke: Deye
Kategorie: Ladegerät
Modell: SUN-12K-G05

Brauchst du Hilfe?

Wenn Sie Hilfe mit Deye SUN-12K-G05 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ladegerät Deye

Bedienungsanleitung Ladegerät

Neueste Bedienungsanleitung für -Kategorien-