DeLonghi Pinguino PACN90.B Bedienungsanleitung

DeLonghi Klimaanlage Pinguino PACN90.B

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für DeLonghi Pinguino PACN90.B (11 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 37 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/11
15
GB
GB
GB
GBGB
Im p o r t a n t s a fe g ua rds
DESCRIPTION
1air outlet grille
2control panel
3handles
4castors
5filter
6evaporator air intake grille
7air exhaust hose housing
8condenser air intake grille
9power cable
10 drain hose cap
11 flange with cap
12 air exhaust hose
13 hose adapter (2 pieces)
14 wall mounting accessory
15 window outlet
16 remote control unit (some models only)
• Use this appliance only as described in this instruction manual.
As with all electrical equipment, whilst the instructions aim to cover as many eventualities as
possible, caution and common sense should be applied when operating and installing this
appliance.
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• The appliance must be installed in conformity with national legislation regulating electrical
equipment and installations.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.
Repairs carried out by unauthorised personnel may be dangerous.
• This appliance must be used exclusively by adults.
• Never allow the appliance to be used by people (including children) with psychological, phy-
sical or sensory impairments or with insufficient experience and knowledge, unless closely
supervised and instructed by someone responsible for their safety.
Young children should be supervised to ensure that they do not play with the appliance.
• The appliance must be connected to an efficient earth system.
Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance, always unplug the appliance from the mains socket.
• Never unplug the appliance by pulling on the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources
of heat.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or
pressurised containers (eg aerosol cans).
• Do not rest heavy or hot objects on top of the appliance.
• Clean the air filter at least once a week.
• Avoid using heating appliances near the air conditioner.
• Always transport the appliance upright or resting on one side.
Before moving the appliance, empty the internal circuit completely of water.
After moving the appliance, wait at least 1 hour before starting it
• When putting the appliance away, do not cover with plastic bags.
• The materials used for packaging can be recycled.
You are therefore recommended to dispose of them in special differentiated waste collection
containers.
• At the end of its working life, consign the appliance to a specialist collection centre.
• If the power cable is damaged, it must be replaced by the manufacturer or an authorised
technical service centre in order to avoid all risk.
SPECIFIC WARNINGS FOR APPLIANCES WITH R410A* REFRIGERANT GAS
R410A refrigerant gas conforms to EC regulations on the environment.
Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).
* Verify the type of refrigerant gas used in your appliance on the rating plate.
16
The instructions below will enable you to prepare your air conditioner for operation as efficiently
as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is
ensured with your air conditioner:
• Screw one of the hose adapters to one
end of the air exhaust hose 12.
• Fit the other adapter to the air exhau-
st hose housing at the back of the
appliance (see fig. A).
• Screw the end of the hose without adapter
to the adapter previously mounted on the
appliance (see fig. A).
7
13
13
• Fit the window outlet to the air
exhaust hose as shown in fig. B.
• Place the air conditioner near a window
or French window.
• Make sure the air exhaust hose is unob-
structed.
15
12
Pre p a r i n g fo r us e
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• The mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• The mains socket and electrical circuit are adequate for the appliance;
• The mains socket matches the plug. If this is not the case, have the plug replaced;
• The mains socket is adequately earthed. Failure to follow these important safety instructions absolves the
manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
• Open the window or French window sligh-
tly and position the outlet as shown in
figure C.
15
A
21
B
C
17
Pre p a r i n g fo r use
AIR-CONDITIONING WITH INSTALLATION
If required, your appliance can also be instal-
led semi-permanently (Fig. D).
• Fit the wall flange accessory provi-
ded in the hole.
• Fit the air exhaust hose in the rele-
vant hose located on the rear side of
the appliance (see fig. A).
• Screw the wall mounting accessory
al tubo uscita aria to the air exhaust
hose or, if necessary, unscrew the
adapter from the air exhaust hose and
replace it with the wall installation terminal
(fig. F).
• Insert the other end of the hose on
the flange as shown in fig. G.
13
12
14
7
13
11
12
14
12
11
Proceed as follows:
• Drill a hole (ø134mm) in an outside wall or
through a window pane.
Respect the height and dimensions of the
hole given in figure E.
134
MAX100 cm
MIN 35 cm
When the hose is not fitted, the hole can
be closed with the flange cap .
NOTE.
When installing the air conditioner semi-per-
manently, you should leave a door slightly
open (as little as 1 cm) to guarantee correct
ventilation.
11
12
in the window
pane
in the wall: you are
recommended to
insulate the section
of wall using suita-
ble insulation.
in the wooden
kickboard of a
French window
E
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
30 cm
30 cm
D1
2F
G
GB
GB
GB
GBGB


Produktspezifikationen

Marke: DeLonghi
Kategorie: Klimaanlage
Modell: Pinguino PACN90.B

Brauchst du Hilfe?

Wenn Sie Hilfe mit DeLonghi Pinguino PACN90.B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage DeLonghi

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-