INTRODUCTION
Thank you for choosing a De’Longhi product. Please take a few
moments to read the instructions to avoid risks or damage to the
appliance.
DESCRIPTION
Description of the appliance (see page 3 - A)
A1 air outlet ap
A2 control panel
A3 handles
A4 castors
A5 BioSilver lter
A6 air intake grille
A7 air exhaust hose housing
A8 air intake grille
A9 power cable
A10 drainage hose with cap
A11 remote control signal receiver
A12 remote control compartment
Description of the accessories (see page 3 - B)
B1 wall ange with cap
B2 air exhaust hose
B3 hose adaptor
B4 adapter for window bracket
B5 window bracket with wing nut
B6 adapter for wall mounting/window outlet
B7 window outlet
B8 remote control
B9 window bracket cap
ELECTRICAL CONNECTION
Before plugging into the mains, check the following:
the mains voltage is the same as that indicated on the plate
on the back of the appliance;
the socket and electrical line are sized to support the load
required;
the socket is the proper type for the plug, otherwise, re-
place the socket;
the socket is connected to an ecient earthing system.
The manufacturer is not responsible in the event of non-
compliance with these injury prevention standards.
The power cable must only be replaced by specialised
technicians.
USE
The instructions below will enable you to prepare your air con-
ditioner for operation as eciently as possible. Before use, make
sure the air intake and outlet grilles are unobstructed.
Please note: This appliance is provided with an auto-evapora-
tion feature for condensate removal during cooling and dehu-
midifying modes.
AIR CONDITIONING WITHOUT INSTALLATION
CASEMENT WINDOW
If you have a casement window proceed as follows:
Fit the air exhaust hose (B2) in the relevant housing located
on the rear side of the appliance (g. 1).
Screw the window outlet (B7) and place outside the win -
dow to exhaust the hot air (g. 2).
DOUBLEHUNG WINDOW
If you have a double-hung window proceed as follows:
Insert and lock the adapter for window bracket (B4) into
the slot of the window bracket (B5) (g.3)
Place the window bracket in the window sill, and extend
the bracket fully within the window frame (g. 4).
Fix the bracket by the wing nut (g. 5) (Should the window
bracket be too large for the window the plastic can be cut
with a saw by a qualied professional).
Insert the air exhaust hose (B2) into the adapter for win-
dow bracket (B4) and rotate it as shown in g. 6.
In order to facilitate the tting of the air exhaust hose (B2)
in the relevant housing located on the rear side of the ap-
pliance, position the hose adapter s tabs (B3) in a vertical
axis as shown in g. 7 and proceed as shown in g.1.
SLIDING WINDOWS
Thanks to the locking wing nut, it’s possible to use the win-
dow bracket also for sliding windows. Position the bracket
vetically with the hole in the lower part so to allow a easier
installation of the exhaust hose.
AIR CONDITIONING WITH INSTALLATION
Fit the air exhaust hose (B2) in the relevant housing located
on the rear side of the appliance (g. 1).
Drill a hole 150 mm in an outside wall or through a window
panel. Respect the distances, dimensions and heigh of the
hole given in gure 8.
13
ø 150mm
in the
window
panel
in the wooden
kickboard of a
French window
in the wall: you are
recommended to
insulate the section
of wall using suita-
ble insulation.
Fit the wall ange (B1) into the hole.
Fit the air exahaust hose (B2) into the wall ange (B1) (Fig.
9)
When the hose (B2) is not connected, the drilled hole can
be closed with the ange cap (B1).
Please note: As special tools are required for installation, we
suggest you have the appliance installed by specialized person-
nel.
When installing the air conditioner, you should leave a door
slightly open little as 1 cm to guarantee correct ventilation
and room pressure.
Keep the air hose as short and free of curves as possible to
avoid constrictions.
OPERATING FROM THE CONTROL PANEL
C1
C15
C13
C12
C11
C10
C9
C8
C7
C6
C16C17
C3
C4
C2
C5
C18
C14
C19
DESCRIPTION OF THE CONTROL PANEL (C)
C1. ON/STAND-BY (on/o) key
C2. MODE selection key (air conditioning, dehumidifying, fan)
C3. Temperature increase key
C4. Temperature decrease key
C5. Fan speed selection key (MIN/MED/MAX/AUTO/SILENT)
C6. Air conditioning symbol
C7. Dehumidifying symbol
C8. Fan symbol
C9. ECO REAL FEEL indicator
C10. Swing symbol
C11. Fan speed indicator
C12. SILENT symbol
C13. Alarm symbol
C14. Set temperature values, programmed on/o time
C15. Timer symbol
C16. Timer hours indicator
C17. Selected temperature scale indicator
C18. UV-Carelight key
C19. UV-Carelight symbol
CONTROL PANEL OPERATION
TURNING THE APPLIANCE ON AND OFF
Insert the plug in the socket. Two dashes appear on the display
indicating that the appliance is in stand-by.
Touch the (C1) key to turn on the appliance.
The ap A1 will open after few seconds. When the appliance
comes on the last function set before it was shut o is activated.
To turn the appliance o, touch the key.
Please note: If start-up is not continued, after a few minutes
the display light dims in order to reduce energy consumption.
Please note: Never turn o the air conditioner by simply pulling
the plug. Touch the key in order to put your air conditioner
in stand-by and wait a few minutes before pulling the plug. In
this way, the appliance can perform the operating status checks.
14
MODES SELECTION
To select the desired operating
mode, touch repeatedly the MODE
key (C2) until the desired function
is selected.
AIR CONDITIONING MODE
This is ideal for hot and humid
weather when the room needs to
be both cooled and dehumidied.
To correctly set this mode:
Touch repeatedly the MODE
key (C2) until the air condition-
ing symbol appears. The
display will show the desired
temperature.
To change the temperature
to be reached, touch the
(C3) or (C4) key.
Select the desired fan speed by touching the (C5) key.
The speeds available are:
Minimum speed: when maximum silent opera
tion is desired.
Medium speed: when the noise level needs to
be low but with a good comfort level.
Maximum speed: to reach the desired
temperature as soon as possible.
Auto: The appliance automatically chooses the
best fan speed based on the temperature select
ed and the environmental conditions.
The operating noise is further reduced.SILENT
The most suitable temperatures during the summer range from 24
to 27°C. However, setting the temperature signicantly lower than
the outdoor temperature is not recommended.
DEHUMIDIFYING MODE
This is ideal for reducing humidity in
the room (spring and autumn, damp
rooms, rainy periods, etc). For this
type of use, the appliance must be set
up as for air conditioning mode. That
is, the air exhaust hose (B2) must be
tted to the appliance to allow the
humidity to be discharged outside.
To correctly set this mode:
Touch repeatedly the MODE key (C2) until the dehumidify-
ing symbol appears.
The appliance will automatically choose the best air ow.
FAN MODE
When using this mode, the air ex-
haust hose (B2) does not need to be
attached to the appliance.
To correctly set this mode:
Touch repeatedly the MODE
(C2) key until the fan sym-
bol appears.
Select the desired air ow by touching the increase
(C3) or decrease (C4) key.
The air ows available are:
Minimum air ow: when most silent operation is
desired.
Medium air ow: when the noise level needs to
be low but with a good comfort level.
Maximum air ow: for maximum performance.
SELECT THE TEMPERATURE SCALE
The temperature can be displayed
in °C or °F. To change the tem-
perature unit of measure touch
simultaneously for ten seconds the
increase (C3) and decrease
(C4) keys.
OPERATING FROM THE REMOTE CONTROL
INSERTING OR REPLACING THE BATTERIES
Remove the cover on the rear of the remote control;
Insert or replace the batteries with two new LR03 AAA
1.5V batteries, inserting them correctly (see the directions
inside the battery compartment) (g. 10);
Replace the cover.
Please note: If the remote control unit is replaced or discarded,
the batteries must be removed and disposed of in accordance
with current legislation as they are harmful to the environment.
Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable
(nickel-cadmium) batteries. Do not dispose of batteries in re.
Batteries may explode or leak. If the remote control is not be
used for a certain length of time, remove the batteries.