Danby DPA053B4WDB Bedienungsanleitung

Danby Klimaanlage DPA053B4WDB

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Danby DPA053B4WDB (72 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 21 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/72
DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
*
*
2021.03.31
PORTABLE AIR CONDITIONER
Owner’s Manual.............................1 - 23
CLIMATISEUR PORTABLE
Manuel du propriétaire.................24 - 46
AIRE ACONDICIONADO PORTÁTIL
Manual del propietario.................47 - 69
MODEL MODÈLE MODELO• •
DPA053B4WDB
DPA070B4WDB
DPA050B7WDB
DPA050B7BDB
1
Welcome to the Danby family.
We are proud of our quality products and we believe in dependable service. We suggest
that you read this owner’s manual before plugging in your new appliance as it contains
important operation information, safety information, troubleshooting, and maintenance tips
to ensure the reliability and longevity of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual provided with
your new appliance.
1. Please write down your appliance information below. You must keep the original proof
of purchase receipt to validate and receive warranty services.
2. Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION
after fi lling out a product survey, at www.danby.com/support/product-registration/
Need Help?
1. Read your Owner’s Manual for installation help, troubleshooting, and maintenance
assistance.
2. Visit www.Danby.com to access self-service tools, FAQs and much more by searching
your model number in the search bar.
3. For the Quickest Customer Service, please fi ll out the web form at www.danby.com/
support. Your submission will go directly to an expert on your particular appliance.
Our average response times are between 20 minutes and 2 hours, during EST business
hours.
4. Call 1-800-263-2629 - please note that during peak hours, hold times can exceed one
hour.
Model Number: ____________________________________________________
Serial Number: ____________________________________________________
Date of Purchase: __________________________________________________
SAVE THESE INSTRUCTIONS!
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining
or disposing of the air conditioner, the refrigerant
must not be allowed to vent into the open air.
WARNING Shows that the appliance uses a fl ammable refrigerant. If the
refrigerant leaks and is exposed to an external ignition source, there is
a risk of re.
CAUTION Shows that the operation manual should be read carefully.
CAUTION Shows that service personnel should be handling this equipment with
reference to the installation manual.
CAUTION Shows that the information is available such as the operating manual
or the installation manual.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
SAFETY PRECAUTIONS
WARNING
Installation must be performed according to the installation instructions. Improper installation can cause
water leakage, electrical shock or fi re.
Use only the included accessories and parts and specifi ed tools for the installation. Using non-standard
parts can cause water leakage, electrical shock, fi re and injury or property damage.
Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord
is equipped with a three-prong grounding plug to protect against shock. Voltage information can be
found on the nameplate of the unit.
You unit must be used in a properly grounded wall receptacle. if the wall receptacle you intend to use is
not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse of circuit breaker
needed is determined by the maximum current of the unit. The maximum current is indicated on the
nameplate located on the unit), have a qualifi ed electrician install the proper receptacle.
Install the unit on a fl at, sturdy surface. Failure to do so could result in damage or excessive noise and
vibration.
The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
Do not modify the length of the power cord or use an extension cord to power the unit.
Do not share a single outlet with other electrical appliances. Improper power supply can cause fi re or
electrical shock.
Do not install you air conditioner in a wet room such as a bathroom or laundry room. Too much
exposure to water can cause electrical components to short circuit.
Do not install the unit in a location that may be exposed to combustible fas as this could cause fi re.
The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over
objects as this could cause tipping.
Do not operate a unit that been dropped or damaged.
The appliance with the electric heater shall have at least 1 meter space from combustible materials.
Do not touch the unit with wet or damp hands or when barefoot.
If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power
supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has
been damaged contact a technician or customer service for assistance.
In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
You air conditioner should be used in such a way that it is protected from moisture. e.g. condensation,
splashed water, etc. Do not place or store you air conditioner where it can fall or be pulled into water
or any other liquid. Unplug immediately if this occurs.
All wiring must be performed strictly in accordance with the wiring diagram location inside the unit.
The units circuit board (PCB) is designed with a fuse to provide over current protection. The
specifi cations of the fuse are printed on the circuit board.
When the water drainage function is not in use keep the upper and lower drain plugs fi rmly installed in
the unit. The drain plugs can be a choking hazard to children.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
CAUTION
This appliance is not intended for use by persons (including children) whose physical, sensory or
mental capabilities may be different or reduced, or who lack experience or knowledge, unless such
persons receive supervision or training to operate the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance. Children must
be supervised around the unit at all times.
If the power supply cord is damaged it must be replaced by the manufacturer, its service agent or
similarly qualifi ed persons in order to avoid a hazard.
Prior to cleaning or other maintenance, the appliance must be disconnected from the power supply.
Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been
dropped or damaged.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do
not route cord under furniture or appliances. Arrange cords away from traf c and where it will not be
tripped over.
Do not operate a unit with a damaged power cord, plug, power fuse or circuit breaker. Discard the unit
or return to an authorized service facility for examination and/or repair.
To reduce the risk of re or electric shock do not use this air conditioner with any solid-state speed
control device.
The appliance shall be installed in accordance with national wiring regulations.
Contact the authorized service technician for repair or maintenance of this unit.
Contact the authorized service installer for installation of this unit.
Do not cover or obstruct the inlet or outlet grilles.
Do not use this product for functions other than those described in this instruction manual.
Before cleaning turn off the power and unplug the unit.
Disconnect the power if strange sounds, smells or smoke comes from it.
Do not press the buttons on the control panel with anything other than your fi ngers.
Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been
dropped or damaged.
Do not operate or stop the unit by inserting or pulling out the power cord plug.
Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the
presence of infl ammable substances or vapour such as alcohol, insecticides, petrol, etc.
Always transport your air conditioner in a vertical position and stand on a stable, level surface during
use.
Always contact a qualifi ed person to carry out repairs. If the damaged power supply cord must be
replaced with a new power supply cord obtained from the product manufacturer and not repaired.
Hold the plug by the head of the power plug when removing it.
Turn off the appliance when not in use.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
Note about uorinated gasses
Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specifi c information
on the type, the amount and the C02 equivalent in tonnes of the uorinated greenhouse gas on some
models. Please refer to the relevant label on the unit itself.
Installation, service, maintenance and repair of this unit must be performed by a certi ed technician.
Product installation and recycling must be performed by a certi ed technician.
WARNING for using R32 refrigerant
Do not use means to accelerate the defrosting process or to clean other than those recommended by the
manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources for example,
open fl ames, an operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that the refrigerants may not contain an odour.
The appliance should be installed, operated and stored in a room with a fl oor area according to the
amount of refrigerant to be charged. For specifi c information on the type of gas and the amount,
please refer to the relevant label on the unit itself. When there are differences between the label and the
manual on the minimum room area description, the description on the label shall prevail.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specifi ed for operation.
Any person involved with working on the refrigerant circuit should hold a current, valid certifi cate from
an industry accredited assessment authority which authorizes their competence to handle refrigerants
safely in accordance with an industry recognized assessment speci cation.
Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of ammable refrigerants.
Please follow the instruction carefully to handle, install, clear and service the air conditioner to
avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When
maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
No open re or device like switch which may generate spark/arcing shall be around air conditioner to
avoid causing ignition of the fl ammable refrigerant used.
Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical
damage from occurring.
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid
any hazard. For speci c information on the type of gas and the amount, please to the relevant label on
the unit itself.
The appliance shall be stored in a room without continuously operating open ames (for example an
operating gas appliance) and ignition sources (for example an operating electric heater).
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
Transport of equipment containing fl ammable refrigerants
See transport regulations.
Marking of equipment using signs
See local regulations.
Disposal of equipment using fl ammable refrigerants
See national regulations.
Storage of equipment / appliances
The storage of equipment should be in accordance with the manufacturer’s instructions.
Storage of packed (unsold) equipment
Storage package protection should be constructed such that the mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations.
Information on servicing
1. Checks to the area: Prior to beginning work on systems containing fl ammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating
system, the following precautions shall be complied with prior to conducting work on the system.
2. Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of
a fl ammable gas or vapour being present while the work is being performed.
3. General work area: All maintenance staff and others working in the local area shall be instructed on
the nature of work being carried out. Work in confi ned spaces shall be avoided. The area around the
work space shall be sectioned off. Ensure that the conditions within the work area have been made safe
by removing all fl ammable material.
4. Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant
detector prior to and during work to ensure the technician is aware of potentially fl ammable
atmospheres. Ensure that the leak detection equipment being used is suitable for use with fl ammable
refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.
5. Presence of
re extinguisher:
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry
powder or C02 re extinguisher adjacent to the work area.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
6. No ignition sources: No person carrying out work in relation to a refrigeration system which involves
exposing any pipe work that contains or has contained ammable refrigerant shall use any sources
of ignition in such a manner that it may lead to risk of re or explosion. All possible ignition sources
including cigarette smoking, should be kept suffi ciently far away from the site of installation, repairing,
removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding
space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there
are no ammable hazards or ignition risks. No smoking signs shall be displayed.
7. Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking
into the system or conducting any hot work. A degree of ventilation shall continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferable expel it externally into the atmosphere.
8. Checks to the refrigeration equipment: Where electrical components are being changed, they shall
be fi t for the purpose and to the correct specifi cation. At all times the manufacturer’s maintenance and
service guidelines shall be followed. If in doubt consult the manufacturers technical department for
assistance.
The following checks shall be applied to installations using fl ammable refrigerants:
The charge size is in accordance with the room size within which the refrigerant containing parts are
installed.
The ventilation machinery and outlets are operating adequately and are not obstructed.
If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence
of refrigerant.
Marking to the equipment continues to be visible and legible. Markings and signs that become illegible
must be corrected.
Refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitable protected
against being corroded.
9. Checks to electrical devices: Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that could compromise safety, then
no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot
be corrected immediately but it is necessary to continue operation, an adequate temporary solution
shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
That no live electrical components and wiring are exposed while charging, recovering or purging the
system.
That there is continuity of earth bonding.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS


Produktspezifikationen

Marke: Danby
Kategorie: Klimaanlage
Modell: DPA053B4WDB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Danby DPA053B4WDB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Danby

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-