Danby DAC080EB6WDB Bedienungsanleitung

Danby Klimaanlage DAC080EB6WDB

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Danby DAC080EB6WDB (23 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 25 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/23
*
*
Printed in China
Imprimé en Chine
Impreso en China
*Trademark of Danby Products
* Marque de commerce de Danby Products
* Marca comerciales de Danby Products
Danby Products Limited, Guelph, Ontario, Canada N1H 6Z9
Danby Products Inc. Findlay, Ohio, U.S.A. 45840
www.Danby.com
2023.01.20
MODEL MODÈLE MODELO• •
DAC080EB6WDB
DAC100EB6WDB
DAC120EB6WDB-6
AIR CONDITIONER
Owner’s Manual.............................1 - 18
CLIMATISEUR
Manual du propriétaire.................19 - 36
AIRE ACONDICIONADO
Manual del propietario..................37 - 54
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
Note about uorinated gasses
Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specifi c information
on the type, the amount and the C02 equivalent in tonnes of the fl uorinated greenhouse gas on some
models. Please refer to the relevant label on the unit itself.
Installation, service, maintenance and repair of this unit must be performed by a certifi ed technician.
Product installation and recycling must be performed by a certifi ed technician.
WARNING for using R32 refrigerant
Do not use means to accelerate the defrosting process or to clean other than those recommended by the
manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources for example,
open fl ames, an operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that the refrigerants may not contain an odor.
The appliance should be installed, operated and stored in a room with a fl oor area according to the
amount of refrigerant to be charged. For specifi c information on the type of gas and the amount,
please refer to the relevant label on the unit itself. When there are differences between the label and the
manual on the minimum room area description, the description on the label shall prevail.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specifi ed for operation.
Any person involved with working on the refrigerant circuit should hold a current, valid certifi cate from
an industry accredited assessment authority which authorizes their competence to handle refrigerants
safely in accordance with an industry recognized assessment specifi cation.
Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of fl ammable refrigerants.
Please follow the instruction carefully to handle, install, clear and service the air conditioner to
avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When
maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
No open re or device like switch which may generate spark/arcing shall be around air conditioner to
avoid causing ignition of the fl ammable refrigerant used.
Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical
damage from occurring.
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid
any hazard. For specifi c information on the type of gas and the amount, please to the relevant label on
the unit itself.
The appliance shall be stored in a room without continuously operating open fl ames (for example an
operating gas appliance) and ignition sources (for example an operating electric heater).
Transport of equipment containing fl ammable refrigerants: See transport regulations.
Marking of equipment using signs: See local regulations.
Disposal of equipment using fl ammable refrigerants: See national regulations.
Storage of equipment / appliances: The storage of equipment should be in accordance with the
manufacturer’s instructions.
Storage of packed (unsold) equipment: Storage package protection should be constructed such that the
mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be determined by local
regulations.
SAVE THESE INSTRUCTIONS!
Labeling
Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label
shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains
ammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended
good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are
employed. Ensure that the correct number of cylinders for holding the total system charge are available.
All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e.
special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and
associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible,
cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment
that is at hand and shall be suitable for the recovery of ammable refrigerants. In addition, a set of
calibrated weighing scales shall be available and in good working order. Hoses shall be complete with
leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it
in satisfactory working order, has been properly maintained and that any associated electrical components
are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder
and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and
especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have
been evacuated to an acceptable level to make certain that ammable refrigerant does not remain within
the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers.
Only electric heating to the compressor body shall be employed to accelerate this process. When oil is
drained form a system, it shall be carried out safely.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS