Daikin FTXS35G Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Daikin FTXS35G (42 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/42
R410A Split Series
INSTALLATION MANUAL
DAIKIN ROOM AIR CONDITIONER
EnglishDeutschFrançaisNederlandsEspañolItaliano
ΕλληνικÜ
Portugues
Рóссêий
Türkçe
Installation manual
Installationsanleitung
Manuel d’installation
Montagehandleiding
Manual de instalación
Manuale d’installazione
Manual de Instalação
MODELS
FTXS60GV1B
FTXS71GV1B
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
DAIKIN INDUSTRIES, LTD.
Low Voltage 2006/95/EC
Electromagnetic Compatibility 2004/108/EC
*
3SB64526-10B
Shinri Sada
Manager Quality Control Department
1st. of Sep. 2009
DAIKIN.TCF.015 M11/08-2009
FTXS60GV1B, FTXS71GV1B
KEMA Quality B.V.
74736-KRQ/EMC97-4957
1 English
Safety Precautions
The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
Meaning of WARNING and CAUTION notices
WARNING ....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ..... Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
The safety marks shown in this manual have the following meanings:
After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or
over heating terminals.
If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and
use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in
the refrigeration cycle, which may result in equipment damage and even injury.
During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
While following the instructions in this installation manual, install drain piping to ensure proper drainage and
insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.


Produktspezifikationen

Marke: Daikin
Kategorie: Klimaanlage
Modell: FTXS35G
WLAN: Nein
Produktfarbe: Weiß
AC Eingangsspannung: 220 - 240 V
AC Eingangsfrequenz: 50 Hz
Typ: Klimaanlageneinheit Innen
Kältemittelart: R410A
Invertertechnologie: Nein
Klimaanlage Funktionen: Cooling, Fan, Heating
Kühlkapazität in Watt (nominal): - W
Energieeffizienzklasse (Kühlen): A
Energieverbrauch pro Stunde (Kühlung): - kWh
Energieverbrauch pro Stunde (Heizung): - kWh
Jährlicher Energieverbrauch (Kühlung): - kWh
Heizleistung in Watt (nominal) (wärmere Heizperiode): - W
Heizleistung in Watt (nominal) (durchschnittliche Heizperiode): - W
Heizleistung in Watt (nominal) (kältere Heizperiode): - W
Jährlicher Energieverbrauch (Heizung) (wärmere Heizperiode): - kWh
Jährlicher Energieverbrauch (Heizung) (durchschnittliche Heizperiode): - kWh
Jährlicher Energieverbrauch (Heizung) (kältere Heizperiode): - kWh
Indooreinheitstyp: Wandmontierbar
Geräuschpegel Innengerät (hohe Geschwindigkeit): 42 dB
Kühlender Luftstrom (indoor unit): 462 m³/h
Aufheizender Luftstrom (indoor unit): 510 m³/h
Anzahl Innengeräte: 1
Breite der Indooreinheit: 800 mm
Tiefe der Indooreinheit: 215 mm
Höhe der Indooreinheit: 295 mm
Innengerätgewicht: 10000 g
Geräuschpegel Außengerät: - dB
Ionisator: Nein
Gasleitungsdurchmesser: 9.52 mm
Durchmesser Flüssigkeitsschlauch: 6.35 mm
Innengerät Paketbreite: 870 mm
Innengerät Pakettiefe: 274 mm
Innengerät Pakethöhe: 366 mm
Verpackungsgewicht Innengerät: 13000 g
Abflussschlauchdurchmesser: 18 mm
Innengerät Schallleistungspegel: 58 dB
Innengerät Lüfterdrehzahl (Kühlung, hohe Geschwindigkeit): 1370 RPM
Innengerät Lüfterdrehzahl (Kühlung, mittlere Geschwindigkeit): 1090 RPM
Innengerät Lüfterdrehzahl (Kühlung, niedrige Geschwindigkeit): 800 RPM
Lüfterdrehzahl Innengerät (Heizung, hohe Drehzahl): 1370 RPM
Lüfterdrehzahl Innengeräte (Heizung, mittlere Drehzahl): 1160 RPM
Lüfterdrehzahl Innengerät (Heizung, niedrige Drehzahl): 940 RPM