Daikin FTXP20L Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Daikin FTXP20L (16 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/16
Operation manual
R32 split series English
Operation manual
R32 split series
FTXP20L2V1B
FTXP25L2V1B
FTXP35L2V1B
Table of Contents
Operation manual
2
FTXP20~35L2V1B
R32 split series
3P511999-1 – 2017.11
Table of Contents
1 About the documentation 2
1.1 About this document.................................................................. 2
2 About the system 2
2.1 Indoor unit ................................................................................ 2
2.2 About the user interface ............................................................ 3
2.2.1 Components: User interface ....................................... 3
2.2.2 Status: User interface LCD ......................................... 3
2.2.3 To operate the user interface...................................... 4
3 Before operation 4
3.1 To fix the user interface to the wall............................................ 4
3.2 To insert the batteries................................................................ 4
3.3 To switch between Fahrenheit and Celsius............................... 4
3.4 To turn on the power supply...................................................... 4
4 Operation 4
4.1 Operation range ........................................................................ 4
4.2 When to use which feature ........................................................ 4
4.3 Operation mode and temperature setpoint................................ 5
4.3.1 To start/stop operation and to set the temperature..... 5
4.3.2 Airflow rate.................................................................. 5
4.3.3 Airflow direction........................................................... 6
4.3.4 Comfort airflow operation............................................ 6
4.3.5 Powerful operation...................................................... 6
4.3.6 Econo operation.......................................................... 7
4.3.7 ON/OFF timer operation ............................................. 7
5 Energy saving and optimum operation 7
6 Maintenance and service 8
6.1 Overview: Maintenance and service ......................................... 8
6.2 To clean the indoor unit and user interface ............................... 9
6.3 To clean the front panel............................................................. 9
6.4 To clean the air filters ................................................................ 9
6.5 To clean the titanium apatite deodorizing filter .......................... 9
6.6 To replace the titanium apatite deodorizing filter....................... 10
6.7 To take following items into account before a long idle period .. 10
7 Troubleshooting 10
7.1 Symptoms that are NOT system malfunctions .......................... 11
7.1.1 Symptom: A sound like water flowing is heard ........... 11
7.1.2 Symptom: A blowing sound is heard........................... 11
7.1.3 Symptom: A ticking sound is heard............................. 11
7.1.4 Symptom: A whistling sound is heard ......................... 11
7.1.5 Symptom: A clicking sound during operation or idle
time is heard ............................................................... 11
7.1.6 Symptom: A clapping sound is heard ......................... 11
7.1.7 Symptom: The units can give off odours..................... 11
7.1.8 Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 11
7.2 Solving problems based on error codes.................................... 11
8 Disposal 12
1 About the documentation
1.1 About this document
Thank you for purchasing this product. Please:
â–ª Keep the documentation for future reference.
Target audience
Endusers
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry, and on farms, or for
commercial and household use by lay persons.
Documentation set
This document is part of a documentation set. The complete set
consists of:
â–ªGeneral safety precautions:
â–ª Safety instructions that you must read before operating your
system
â–ª Format: Paper (in the box of the indoor unit)
â–ªOperation manual:
â–ª Quick guide for basic usage
â–ª Format: Paper (in the box of the indoor unit)
â–ªUser reference guide:
â–ª Detailed step-by-step instructions and background information
for basic and advanced usage
â–ª Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.
The original documentation is written in English. All other languages
are translations.
2 About the system
WARNING: FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
2.1 Indoor unit
CAUTION
Do NOT insert fingers, rods or other objects into the air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.
INFORMATION
The sound pressure level is less than 70dBA.
WARNING
â–ª Do not modify, disassemble, remove, reinstall or repair
the unit yourself as incorrect dismantling or installation
may cause an electric shock or fire. Contact your
dealer.
â–ª In case of accidental refrigerant leaks, make sure there
are no naked flames. The refrigerant itself is entirely
safe, non-toxic and mildly flammable, but it will
generate toxic gas when it accidentally leaks into a
room where combustible air from fan heaters, gas
cookers, etc. is present. Always have qualified service
personnel confirm that the point of leakage has been
repaired or corrected before resuming operation.
2 About the system
Operation manual
3
FTXP20~35L2V1B
R32 split series
3P511999-1 – 2017.11
aAir inlet
bAir outlet
cFlap (horizontal blade)
dLouvers (vertical blades)
eFront panel
fModel name plate
gRoom temperature sensor
hSignal receiver
iOperation lamp (green)
jTimer lamp (orange)
kIndoor unit ON/OFF switch
lTitanium apatite deodorizing filter
mAir filter
ON/OFF button
If the user interface is missing, you can use the ON/OFF button on
the indoor unit to start/stop operation. When operation is started
using this button, the following settings are used:
â–ª Operation mode = Automatic
▪ Temperature setting = 25°C
â–ª Airflow rate = Automatic
2.2 About the user interface
â–ª Do NOT expose the user interface to directDirect sunlight.
sunlight.
â–ª Dust on the signal transmitter or receiver will reduceDust.
sensitivity. Wipe off dust with a soft cloth.
â–ª Signal communication might be disabled ifFluorescent lights.
fluorescent lamps are in the room. In that case, contact your
installer.
â–ª If the user interface signals operate otherOther appliances.
appliances, move the other appliances, or contact your installer.
â–ª Make sure that the signal between the unit and the userCurtains.
interface is NOT blocked by curtains or other objects.
NOTICE
â–ª Do NOT drop the user interface.
â–ª Do NOT let the user interface get wet.
2.2.1 Components: User interface
aDisplay (LCD)
bAuto button
cDirect operation button
dTemperature adjustment button
eComfort button
fPowerful button
gON timer button
hSignal transmitter
iOFF button
jFan setting button
kEcono button
lSwing button
mOFF timer button (Night set mode)
nTimer cancel button
2.2.2 Status: User interface LCD
Icon Description
Operation mode = Automatic
Operation mode = Drying
Operation mode = Heating
Operation mode = Cooling
Operation mode = Fan only
Powerful operation is active
Econo operation is active
The indoor unit receives a signal from the user
interface
Current temperature setting
Airflow rate = Automatic


Produktspezifikationen

Marke: Daikin
Kategorie: Klimaanlage
Modell: FTXP20L

Brauchst du Hilfe?

Wenn Sie Hilfe mit Daikin FTXP20L benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Daikin

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-