Ctek MXS 7.0 Bedienungsanleitung

Ctek Ladegerät MXS 7.0

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Ctek MXS 7.0 (6 Seiten) in der Kategorie Ladegerät. Dieser Bedienungsanleitung war für 29 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
EN
EN • 3
ABSORPTION, READY TO USE
ANALYSE
RECOND
RECOND
MODE
12V/7A
MXS 7.0
SUPPLY
SUPPLY
NORMAL
AGM
CONGRATULATIONS
to the purchase of your new professional switch mode battery charger.
This charger is included in a series of professional chargers from CTEK AB and SWEDEN
represents the latest technology in battery charging.
CTEK COMFORT CONNECTeyelet M8
CTEK COMFORT CONNECT
MAINS CABLE
CTEK COMFORT CONNECTclamp
CHARGE CABLE
SUPPLY PLUG*
*Supply plugs may dif fer to suit your wall socket.
NORMAL
BATTERY
PROGRAM
ERROR LAMP
AGM
BATTERY
PROGRAM
RECOND
PROGRAM
SUPPLY
PROGRAM
POWER
LAMP
CHARGING
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is ready to start the engine when is lit.
The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE-
BUT TON
MANUAL
DESULPHATION
SOFT START BULK FLOAT, FULLY CHARGED
PULSE, MAINTENANCE CHARGING
20015462E MXS 7.0, Manual EU, Print file 002.indd 3 2011-10-11 07:58:00
4 • EN
BATTERY SIZE (Ah) TIME TO 80% CHARGED
20Ah 2h
50Ah 6h
100Ah 12h
150Ah 17h
READY TO USE
The table shows the estimated time for empty battery to 80% charge
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Program Battery
Size (Ah) Explanation Temp range
NORMAL 14–225Ah
Normal battery program
14.4V/7A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
+5°C+5C
(41ºF–122ºF)
AGM
14225Ah
AGM battery program 14.7V/7A
Use for AGM batteries.
-20°C–+5°C
(-4ºF–41ºF)
RECOND 14–225Ah
Recond program 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds the
Recond step to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
-20°C–+50°C
(-4ºF122ºF)
14225Ah
Supply program 13.6V/7A
Use as 12V power supply or use for
float maintenance charging when 100%
capacity of the battery is required.
Supply program activates Float step
without time or voltage limitation.
-20°C–+50°C
(-4ºF122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the
batterys positive pole?
2. Is the charger connected to a 12V battery?
3. The clamps are short circuited?
4. Has charging been interrupted in or ?
Restart the charger by pressing the MODE-button. If charging is
still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
20015462E MXS 7.0, Manual EU, Print file 002.indd 4 2011-10-11 07:58:02
EN
EN • 5
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead
plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a
defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be replaced.
STEP 6 RECOND
Choose the Recond program to add the Recond step to the charging process. During the Recond step
voltage increases to create controlled gasing in the battery. Gasing mixes the battery acid and gives
back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95100% capacity. The charger monitors the battery voltage and gives a
pulse when necessary to keep the battery fully charged.
1
VOLTAGE (V)CURRENT (A)
ANALYSE RECOND PULSE
DESULPHATION SOFT START BULK ABSORPTION
14.4V
Increasing voltage
to 14.7V @ 25°C
7A
7A until 12.6V Increasing voltage
to 14.4V @ 25°C
7A
1 7
Limit: Max 20h Max 10h 3 minutes 30 min or 4h
depending on
battery voltage
10 days
Charge cycle restarts
if voltage drops*
Charge cycle restarts
if voltage drops
Max 8h
14.7V
14.4V 7A until 12.6V
7A until 12.6V
Increasing voltage
to 14.4V @ 25°C
7A
14.4V @ 25°C
Declining current
14.7V @ 25°C
Declining current
14.4V @ 25°C
Declining current
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Max 13.6V
7A
13.6V
7A
13.6V
7A
13.6V
7A
12.9V‒14.4V
7‒2A
12.9V‒14.7V
7‒2A
12.9V‒14.4V
7‒2A
Max 8h
2 3 4 5
FLOAT
6 8
RECOND
SUPPLY
AGM
NORMAL
Max 15.8V
1.5A
CHARGING PROGRAM
*Supply program is not time or voltage limited.
20015462E MXS 7.0, Manual EU, Print file 002.indd 5 2011-10-11 07:58:03


Produktspezifikationen

Marke: Ctek
Kategorie: Ladegerät
Modell: MXS 7.0

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ctek MXS 7.0 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ladegerät Ctek

Bedienungsanleitung Ladegerät

Neueste Bedienungsanleitung für -Kategorien-