Seite 1/4
Product Overview
The strobe outdoor siren can be used as a wireless siren by connecting to the control panel as well as a
standalone alarm system to work with wireless accessories in same frequency by learning.
The solar-powered siren is a totally wireless siren, designed to help protect yards, driveways, gardens
and all types of other external locations. The strobe siren is battery powered and kept re-charging by
the built-in solar panel. The signal transmission is all by wireless radio frequency which achieves
significantly wirefree transmission and enhances the flexibility to install. Users can install some outdoor
strobe sirens to deter the intruders in Omni-directional guard.
SPS-260
Solar-Powered Siren
User Manual
PCB Layout
2minutes
Siren Duration Setting
5minutes
5MIN 2MIN 30S 5MIN 2MIN 30S
Volume Setting
High (default) Mute
HIGH MUTE LOW
HIGH MUTE LOW HIGH MUTE LOW
Low
Jumper Setup
30seconds (default)
5MIN 2MIN 30S
1. Load the 9V battery.
2. Set the volume and duration of the siren.
3. Start to use by pressing the power button on.
Connect to Alarm Panel
Press the learning button (0.5 seconds), the wireless siren goes into
connecting status after one beep is heard. Press or button on Arm
the panel. The wireless siren is connected successfully with the control
panel after another beep.
To give up the connection, press the learning button again to exit.
Note: Please don't trigger any accessory during connecting with alarm panel.
Usage
Work as a Wireless Siren
After connected to the alarm panel, the siren will hoot and the strobe light will flash when the alarm
panel alarms.
Getting Started
External Tamper Switch
Note: The status LED will flash once every 5 seconds in arm status. It will not flash when in disarm status.
The siren will sound immediately if the tamper switch is triggered.
Learning Button
Internal Tamper Switch
Status LED Indicator
Alarm LED Indicators
Volume Setting
Siren Duration Setting
Power On/Off
18650
9V 6F22
Installation
Note: No matter the siren works as a wireless siren or an alarm panel, if disarm is not operated after the
siren duration time, the status indicator of siren will flash once every 2 seconds to inform user or patrol
police that the alarm system has been triggered. This LED indication lasts for 1 hour.
Work as an Alarm Panel
Service Mode
When the siren is working as a standalone alarm system and installed on the wall, newly purchased
accessories may not easy to connect with the siren. With this function, user can easily connect the
accessories to the siren without dismounting the siren from the wall.
Press on the remote control 3 times (within 5 seconds) to enter service mode.
Then press 3 times (within 5 seconds) to enter connecting status.
A longer beep is heard from the siren means it enters connecting status, press test button on the newly
purchased accessory or trigger the accessory once. Another beep is heard from the siren, the accessory
has been successfully connected with the siren.
Press on remote control to exit connecting status after a short beep.
Enter/Exit Connecting Status by Connected Remote Control
Ver : SPS-260-EN-1407-V2.0-1
2014 Chuango. All Rights Reser ved.
Specifications
Backup Power
Solar Panel Output Current
Maximum Alarm Current
Wireless Receiving Distance
Operation Condition:
Maximum Siren Volume
Static Current
Standby Time
Wireless Receiving Frequency
Housing Material
Size (L x W x H)
Drill four holes and
fit the wall plugs,
and then fit
supplied fixing
screws in the
holes.
Hinge the front cover
locating tabs over the top
edge of the back plate and
carefully push the base of
the siren cover into place.
Secure the siren cover in
place by refitting the fixing
screw in the bottom edge
of the cover.
After connected with wireless accessories, the siren will hoot and the strobe light will flash to deter the
burglar on site when the accessories detect intrusion.
Hold the mounting
plate in position and
mark the positions of
the four mounting
holes. A spirit level
placed on the water-
proof casing will ensure
a perfect level.
Remove the fixing
screw from the bottom
edge of the siren
housing and carefully
remove front cover.
Connect with Wireless Accessories
Press the learning button (0.5 seconds), the system goes into connecting status after one beep is heard.
Press test button on accessories or trigger the accessory once. The wireless accessory is connected
successfully after another beep. To give up the connection, press the learning button again to exit
connecting status after one beep.
1.
2.
18650 3.7V 1200mAh rechargeable lithium battery x 1
9V 6F22 battery x 1
2000LUX illumination 4mA (in sunlight) ≥
≤500mA
≤80m (in open area)
Temperature -10 55 ℃~+ ℃
Relative Humidity 80% (non-condensing) ≤
110dB
≤1mA
≤30 days (in case of no sunlight)
433.92MHz ( ±75KHz)
PC + ABS + ANTI-UV
309 x 230 x 79.7mm
The service mode is to prevent triggering the alarm when you mount the siren on the wall.
When the remote control is connected with the siren, press on remote control 3 times (within 5
seconds), the siren goes into service mode when a long beep is heard. During this period, the siren will
not alarm but beep even if the tamper switch or the sensors connected are triggered. This brings you
convenience on installation.
Press on remote control to exit service mode after a short beep.
Produktspezifikationen
Marke: | Chuango |
Kategorie: | Alarmanlage |
Modell: | SPS-260 |
Produktfarbe: | Black, Red, White |
Internationale Schutzart (IP-Code): | IP55 |
Typ: | Drahtlose Sirene |
Akku-/Batteriespannung: | 3.7 V |
Warnung Dezibel: | 115 dB |
Bereitschaftsstrom: | 1200 mA |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Chuango SPS-260 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Alarmanlage Chuango
28 August 2024
28 August 2024
19 August 2024
15 August 2024
15 August 2024
13 August 2024
1 August 2024
26 Juli 2024
25 Juli 2024
24 Juli 2024
Bedienungsanleitung Alarmanlage
- Alarmanlage Basetech
- Alarmanlage Hama
- Alarmanlage Nedis
- Alarmanlage Brennenstuhl
- Alarmanlage Bosch
- Alarmanlage Velleman
- Alarmanlage Eminent
- Alarmanlage IKEA
- Alarmanlage Schwaiger
- Alarmanlage König
- Alarmanlage Renkforce
- Alarmanlage Blaupunkt
- Alarmanlage Schneider
- Alarmanlage Dometic
- Alarmanlage Pyle
- Alarmanlage Vivanco
- Alarmanlage Abus
- Alarmanlage Elro
- Alarmanlage EZVIZ
- Alarmanlage Imou
- Alarmanlage Olympia
- Alarmanlage Smartwares
- Alarmanlage Yale
- Alarmanlage Gigaset
- Alarmanlage Burg Wächter
- Alarmanlage Honeywell
- Alarmanlage Redmond
- Alarmanlage Doro
- Alarmanlage Kodak
- Alarmanlage Techly
- Alarmanlage Schellenberg
- Alarmanlage Xavax
- Alarmanlage Monacor
- Alarmanlage FireAngel
- Alarmanlage Kidde
- Alarmanlage Optex
- Alarmanlage Aritech
- Alarmanlage Desq
- Alarmanlage M-e
- Alarmanlage Eufy
- Alarmanlage Grothe
- Alarmanlage EVOLVEO
- Alarmanlage Ring
- Alarmanlage Swann
- Alarmanlage Hikvision
- Alarmanlage Electia
- Alarmanlage Somfy
- Alarmanlage KlikaanKlikuit
- Alarmanlage Protector
- Alarmanlage Steren
- Alarmanlage Woonveilig
- Alarmanlage X4-Tech
- Alarmanlage Vimar
- Alarmanlage Dahua Technology
- Alarmanlage Tzumi
- Alarmanlage FBT
- Alarmanlage Pentatech
- Alarmanlage Olymp
- Alarmanlage Chacon
- Alarmanlage Kemo
- Alarmanlage ORNO
- Alarmanlage DSC
- Alarmanlage Cordes
- Alarmanlage Schabus
- Alarmanlage Qolsys
- Alarmanlage Gripo
- Alarmanlage ETiger
- Alarmanlage ConiuGo
- Alarmanlage Bearware
Neueste Bedienungsanleitung für -Kategorien-
3 Oktober 2024
3 Oktober 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024