Casio Collection MCW-200H-1AVEF Bedienungsanleitung

Casio Armbanduhr Collection MCW-200H-1AVEF

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Casio Collection MCW-200H-1AVEF (1 Seiten) in der Kategorie Armbanduhr. Dieser Bedienungsanleitung war für 35 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
1
Operation Guide 5490
MA1510-EA © 2016 CASIO COMPUTER CO., LTD.
Speci cations
Accuracy: ±20 seconds average per month
Stopwatch: Measuring Capacity: 9'59" (10 minutes)
Measuring Unit: 1 second
Measurements: Elapsed time; split time; two nishes
Battery: One silver oxide battery (Type: SR920SW)
Battery Life: Approximately 3 years
Perform the following procedure if the stopwatch hands do not return to their 0 (zero)
positions when you reset the stopwatch.
Correcting the 0 Positions of the Hands
Pull the out to Click 2. Crown
Use (clockwise) and (counterclockwise) to move the A B
Stopwatch Second Hand to 12 o’clock and the Stopwatch Minute Hand
to 0.
x Holding down either button will move the second hand at high speed, until you
release the button.
x The Stopwatch Minute Hand is syncronized with the Stopwatch Second Hand .
After all of the hands are the way you want, push the Crown back in.
Important!
x Timekeeping stops while the crown is pulled out. Correct the current time setting
after performing the above operation.
Using the Stopwatch
Important!
x Do not operate the stopwatch with the crown pulled out.
Note
x An elapsed time operation will stop automatically at the end of 10 minutes.
The stopwatch measures elapsed time in 1-second increments up to 9minutes,
59seconds.
Elapsed time
A A A A B
Start Stop Resume Stop Reset
Split time
A B B A B
Start Split Split release Stop Reset
Two nishes
A B A B B
Start Split
First runner
nishes.
Display time of
rst runner.
Stop
Second runner
nishes.
Split release
Display time of
second runner.
Reset
To change the day indicator setting
To adjust the time setting
Pull the out to Click 1. Crown
Push the back in. Crown
Push the back in. Crown
Rotate the to change the Crown
time setting.
When the second hand is at
12 o’clock, pull the Crown out to
Click 2.
Rotate the towards you to Crown
set the day.
Note
x Take care that you set the correct AM
or PM time.
x When changing the time, move the
minute hand four or fi ve minutes past
your fi nal setting, and then back it up
to the setting you want.
Note
x The day indicator setting uses a 31-
day month. Make adjustments for
months of shorter lengths.
x Avoid changing the day indicator
setting between the hours of 9
p.m. and 1 a.m. Otherwise, the day
indicator may not change correctly at
midnight.
Stopwatch functions
Crown Operations
Some water-resistant models (100 meters, 200 meters)
have a screw-in crown. When you need to perform a crown
operation, rotate it towards you to unscrew it. Then pull
the crown out. Avoid applying undue force when pulling.
The watch loses its water resistance while the crown is
unscrewed. After performing a crown operation, fully screw
the crown back in.
Crown
Loosen
If your watch has a rotary bezel...
You can rotate the bezel to align its mark with the
minute hand. Then you will be able to tell how much
time has elapsed since aligning the mark.
Start
Elapsed time
Current
x Your watch may differ somewhat from the one shown in the illustration.
x Some models may use a combination of hands and rotating disks to indicate
information. The word “hand” in this section is used to mean both analog hands
and rotating disks.
30
Click 2
Click 1
Day Indicator
24 Hour Hand
Second Hand
Hour Hand
Minute Hand
Stopwatch Second Hand
Stopwatch Minute Hand
Crown


Produktspezifikationen

Marke: Casio
Kategorie: Armbanduhr
Modell: Collection MCW-200H-1AVEF

Brauchst du Hilfe?

Wenn Sie Hilfe mit Casio Collection MCW-200H-1AVEF benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Armbanduhr Casio

Bedienungsanleitung Armbanduhr

Neueste Bedienungsanleitung für -Kategorien-