2
VERY IMPORTANT - APPLYING THE SEALANT
Important - The diagram below shows how the sealant should be applied.
1
INSTALLATION
The Purchaser is responsible for the installation of the hob. The Manufacturer does not
accept any responsibility for any damage or loss resulting from incorrect installation,
and as such this will not covered by the Manufacturer’s Guarantee.
The hob may be installed in any worktop which is heat resistant to a temperature of
100° C, and has a thickness of 25 - 40 mm. The dimensions of the insert to be cut
out of the worktop are in shown in Fig. 1.
If the Hob is fitted next to a cabinet on either side,
the distance between the Hob and the cabinet
must be at least 150 mm (see Fig. 2); while the
distance between the hob and the rear wall must
be at least 55 mm.
If no other appliance is fitted below Hob, there
must be a partition panel in insulating material
(wood or similar) providing a space of at least 10
mm below the Hob (see Fig. 2).
The Hob unit is fitted by attaching the Fixing
Clamps supplied, using the holes at the base of
the unit.
TECHNICAL CHARACTERISTICS
Cooking hobs 60x50 Gas Electric
Burners 4 gas –
– 4 elec.
Reference type P4 01 PE 03
Supply Voltage/Frequency (V/Hz) 220-240/50 *
Installed electric power (W) – 6300
Gas burner power:
Small burner kW 1,45 (x 3) –
Large burner kW 2,9 –
Power of gas installed:
- G20/20 mbar (kW) 7,45
- G30/28-30 mbar (g/h) 542
Electric ignition yes –
Product size mm. 585x500 585x500
Degree protection – Type Y
Class 3
Reference on electrical diagram
(page 10) 1
Fig. 1
Fig. 2
Partition panel
30 mm
min.
30 mm
10 mm
Fig. 4 Fig. 4 bis
* 220-240V~/380-415V3N~
This appliance has been designed for non-professional, i.e. domestic, use.
4
The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp
plug/socket is not suitable. A double pole switch must be provided and the circuit must
have appropriate fuse protection. Further details of the power requirement of the in-
dividual product will be found in the users’ instruction and on the appliance rating plate.
In the case of built-in product you are advised, should you wish to use a longer cable
than the one supplied, that a suitably rated heat resistant type must be used.
(Rubber
insulated cable type H05RR-F must be used. The cables should be 1,5 mm2section
for products with electrically heated elements, and 0,75 mm2for others products.
Also, the maximum external diameter of the cable should not be greater than 7 mm.)
The wiring must be connected to the mains supply as follows:
CONNECT TO SPUR TERMINAL
Green & Yellow Wire Earth Connection
Blue Wire Neutral Connection
Brown Wire Live Connection
Note: We do not advocate the use of earth leakage devices with electric cooking
appliances installed to spur points because of the «nuisance tripping» which may occur.
You are again reminded that the appliance must be correctly earthed, the manu-
facturer declines any responsibility for any event occurring as a result of incorrect
electrical installation.
Installation of electrical connections
Declaration of compliance: This equipment, in the parts intended to come into con-
tact with food, complies with the regulations laid down in EEC directives 89/109.
This appliance complies with directive 89/336/EEC, 73/23/EEC, 90/396/EEC and
the following changes.
3
Appropriate checks and tests have ensured that, even in the most extreme conditions,
the temperatures reached are within acceptable limits where there is another appliance
below the Hob, it is recommended that an insulated heat resistant panel is fitted to pro-
vide added protection to the Hob control switches
. The Hob is thermally insulated (in
line with Regulation EN) and may be installed: next to panels higher than the
worktop, for type «Y», or next to panels not higher than the worktop for type «X».
See technical characteristics table «Degree of protection».
Instructions for the installer
The following information is intended for qualified and competant persons only who will
ensure that your appliance is installed correctly. All current legislation concerning the
installation of Gas appliances must be observed by the installer*
* For the U.K. only - By law, the gas installation/commissioning must be carried out
by a «Corgi», registered installer.
This appliance must be installed in accordance with applicable regulations and should
only be used in well-ventilated locations. Before using this appliance carefully study the
instruction book.
Electrical connection (4 electric plates)
In the installation of this appliance a DOUBLE POLE SWITCH must be incorpo-
rated into the electrical connection.
The electric hob should always be connected to the 30 amp supply by a qualified elec-
trician.
To substitute the power supply cord, unscrew the 3 screws marked “A” to remove the
cover. In this instance it must be connected to the mains supply via the appropriately
rated cable/flex. Connect the supply cord to the terminal block and to the earth terminal
(Fig. 4).
Fasten the cord by means the 2 screws marked “B” and reset the cover (Fig. 4 bis).
Before connecting the appliance check the efficiency of the earth circuit. Earthing of
the appliance is required by law. The manufacturer declines any responsibility should
this safety measure not be observed. Connection to the electrical supply should be
made by 4.00 mm2flex 85° C BS 6007 and connected through the cooker junction unit
to the cooker control unit.
To connect the cable remove the protection cover and insert the cable through the ca-
ble chock and fasten it. Effect the connection according to the diagram shown on the
label fixed to the side of terminal board, taking care to connect the earth wire to the
treaded pin near the terminal board.
Always seek the advice of a qualified electrician regarding installation.
Electrical connection
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the mains supply must
be made by a competant electrician, ensuring that all current regulations concerning
such installations are observed.