UPON COMPLETION OF THE INSTALLATION THE INSTALLER
MUST INSTRUCT THE OWNER AND OPERATOR ON THE
FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER
AND THE HEATING SYSTEM
THIS MANUAL SHOULD BE HANDED TO THE OWNER AND
OPERATOR OF THE APPLIANCE.
INSTALLER MUST REVIEW ALL SAFETY INSTRUCTIONS WITH THE
OWNER AND OPERATOR.
DANGER!
The installation instructions included in this Manual are intended
solely for use by a trained and certified installer, service company or
the gas supply company. If the information in this manual is not
followed, a fire or explosion may result causing property damage,
personal injury, or death.
ï”ï Have installation and service performed by a trained and certified
installer or service company, or the gas supply company.
ï”ï Bosch recommends signing a service and maintenance contract
with a trained and certified installer or service company that
covers annual servicing and condition-based maintenance.
Proper maintenance is a fundamental requirement for safe and
efficient operation and long service life.
ï” The boiler must be serviced annually including the main burner,
ignition burner, the entire venting system, and the combustion
air supply. All parts that show any signs of damage or corrosion
must be replaced.
ï” The owner and operator is responsible for the operational safety
and regulatory compliance of the heating system.
ï”ï Improper installation, adjustment, alteration, service, or
maintenance can cause property damage, personal injury, or
death. Refer to this manual and consult a trained and certified
installer or service company, or the gas supply company before
installation, service or maintenance.
Installation Instructions
Stainless Steel Condensing Boiler
Buderus SB625WS/Buderus SB745WS
6 720 805 220-00.1T
Low temperature condensing boilers for gas/oil fired power burners
6 720 805 218 (2016/02) en-us

2 Contents |
SB625WS/SB745WS6 720 805 218 (2016/02)
Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . 3
1.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . 3
2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Certification and testing mark . . . . . . . . . . . . . . . . . . . . . 6
2.3 Regulations and Guidelines . . . . . . . . . . . . . . . . . . . . . . . 6
2.3.1 National regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3.2 Compliance with standards and regulations . . . . . . . . . . 6
2.3.3 Additional regulations for installations in the
Commonwealth of Massachusetts . . . . . . . . . . . . . . . . . 6
2.4 Suitable fuels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.7 Tools, materials and auxiliary equipment . . . . . . . . . . . . 8
2.8 Data plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.9 Dimensions and specifications . . . . . . . . . . . . . . . . . . . . 9
2.9.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.9.2 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.9.3 Water connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Water treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1 Chemical and physical characteristics . . . . . . . . . . . . . 13
3.2 Central heating system . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2.1 Limescale deposits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2.2 Deposit corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.3 Stray current corrosion . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.4 Diffused and localized acid corrosion . . . . . . . . . . . . . . 14
3.3 New central heating systems . . . . . . . . . . . . . . . . . . . . . 14
3.4 Reconditioning old heating systems . . . . . . . . . . . . . . . 14
3.5 Elimination air and gas from central heating system . . 14
3.6 Use of Antifreeze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1 Boiler Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2 Assembling the paneling . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3 Refitting the door hinges . . . . . . . . . . . . . . . . . . . . . . . . 19
5.3.1 Changing the direction of door opening . . . . . . . . . . . . 19
5.3.2 Removing the hinge assembly âBâ . . . . . . . . . . . . . . . . . 22
5.4 Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.5 Combustion gas exhaust . . . . . . . . . . . . . . . . . . . . . . . . 23
5.6 Venting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.7 Code Required Vent Terminations . . . . . . . . . . . . . . . . . 24
5.8 Combustion Air from outside the building . . . . . . . . . . 24
5.9 Combustion Air from an adjacent room . . . . . . . . . . . . 25
5.10 Condensate Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.11 Condensate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.11.1 Draining the condensate . . . . . . . . . . . . . . . . . . . . . . . . 25
5.11.2 Neutralizing the condensate . . . . . . . . . . . . . . . . . . . . . 25
6 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.1 Control unit settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2 Hydraulic connection to the heating system . . . . . . . . . 27
6.3 Hydraulic flow through boiler . . . . . . . . . . . . . . . . . . . . 27
6.4 Making the electrical connection . . . . . . . . . . . . . . . . . . 28
6.5 Fitting temperature sensors . . . . . . . . . . . . . . . . . . . . . 29
6.6 Flushing the heating system . . . . . . . . . . . . . . . . . . . . . 29
6.7 Filling the heating system . . . . . . . . . . . . . . . . . . . . . . . 30
6.8 Preparing the heating system for operation . . . . . . . . . 30
6.9 Commissioning the control unit and burner . . . . . . . . . 30
6.10 Setting control unit parameters . . . . . . . . . . . . . . . . . . . 30
6.11 Commissioning report . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7 Shutting down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.1 Shutting down the heating system . . . . . . . . . . . . . . . . 32
7.2 Shutting down the heating system in an emergency . . 32
8 Inspection and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.1 Why is regular maintenance important? . . . . . . . . . . . . 32
8.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2.1 Opening the door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2.2 Adjusting the door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.3 Cleaning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.4 Checking and correcting the water pressure . . . . . . . . 34
8.4.1 When should you check the water pressure in the
heating system? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.4.2 Sealed unvented systems . . . . . . . . . . . . . . . . . . . . . . . 35
8.5 Inspection and maintenance reports . . . . . . . . . . . . . . 36
9 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
11 Environmental protection/disposal . . . . . . . . . . . . . . . . . . . . . 46
12 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Key to symbols and safety instructions 3 |
6 720 805 218 (2016/02)SB625WS/SB745WS
1 Key to symbols and safety instructions
1.1 Explanation of symbols
Warnings
Keywords at the start of a warning indicate the type and seriousness of
the ensuing risk if measures to prevent the risk are not taken.
The following keywords are defined and can be used in this document:
âą indicates that property damage may occur.NOTE
âą indicates that personal injury may occur.CAUTION
âą indicates that severe personal injury may occur.WARNING
âą indicates that severe personal injury or death may occur.DANGER
Important information
Additional symbols
1.2 General safety instructions
If you hear gas leaking
ⶠLeave the building immediately.
ⶠPrevent others from entering the building.
ⶠNotify the police and fire department from outside the building.
ⶠFrom outside the building, call the gas supply company and a trained
and certified installer or service company.
If you smell gas
ⶠTurn off the gas shut-off valve.
ⶠOpen windows and doors
ⶠDo not touch any electrical switch, telephone, and do not use outlets.
ⶠExtinguish all open flames.
ⶠDo not smoke!
ⶠDo not use lighters!
ⶠWarn all occupants of the building that they need to leave the
building.
ⶠDo not ring doorbells!
ⶠNotify the police and fire department from outside the building.
ⶠFrom outside the building, call the gas supply company and a trained
and certified installer or service company.
If you smell flue gas
ⶠSwitch off the appliance.
ⶠOpen windows and doors.
ⶠInform a trained and certified heating contractor.
DANGER: Risk of fatal injury from failing to consider your own
safety!
ⶠNever risk your own life. Your own safety must always take the
highest priority
NOTICE: Risk of appliance damage from improper operation of the
boiler!
ⶠOnly use the boiler for its intended purpose.
ⶠOnly operate the boiler if it has been installed and maintained per the
instructions provided in the Installation Manual.
ⶠDo not attempt to operate an appliance if any part of it is not in
working order or is damaged.
ⶠUse only original spare parts! The use of parts not supplied by the
manufacturer may cause damage to the boiler, other property and
personal injury. Also, boiler damage caused by the use of
unauthorized parts is not covered by the warranty.
DANGER: Risk of fire when soldering and brazing!
ⶠTake appropriate protective measures when soldering and brazing
around combustible and flammable material.
NOTICE:
ⶠThe installation must comply with all applicable national, state, and
local codes, rules, and regulations.
ⶠThe operator is responsible for the operational safety and regulatory
compliance of the heating system.
ⶠIn the Commonwealth of Massachusetts, the appliance must be
installed by a licensed plumber or gas fitter.
DANGER: Risk of personal injury or death from flue gas poisoning!
ⶠDo not install a thermostatic flue gas damper downstream of the draft
hood.
ⶠDo not tamper with, remove, or attempt to repair the blocked vent
switch.
ⶠWhen replacing the blocked vent switch, install the new part in the
original location.
ⶠA blocked vent switch tripping more than once indicates a problem
with the venting system or chimney which must be repaired
immediately.
ⶠEnsure none of the vent pipes and chimneys are damaged or blocked.
ⶠConnect only one appliance to each venting system or chimney.
ⶠThe venting system must not feed into or route through another air
extraction duct.
ⶠThe venting system must be inspected annually. All parts that show
any signs of damage or corrosion must be replaced.
ⶠNever close off or reduce the size of the combustion air openings.
ⶠThe boiler must not be operated until any obstructions have been
removed.
DANGER: Risk of personal injury or death from explosion!
ⶠWork on gas components may only be carried out by a trained and
certified installer or service company.
ⶠAppliance installation, the connection of gas and vent piping, initial
commissioning, electrical connections, and service and maintenance
must only be carried out by a trained and certified installer or service
company.
Warnings in this document are identified by a warning
triangle printed against a grey background.
Important information for the proper use of the boiler is
also provided in this manual. You will find the
information with a symbol shown on the left and
bordered by horizontal lines above and below the text.
Symbol Meaning
ⶠSequence of steps
ï Cross-reference to other points in this document or to
other documents
âą Listing/list entry
â Listing/list entry (2nd level)
Table 1 Additional symbols
Produktspezifikationen
Marke: | Buderus |
Kategorie: | Durchlauferhitzer und Boiler |
Modell: | SB745WS |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Buderus SB745WS benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Durchlauferhitzer und Boiler Buderus

1 November 2023

23 September 2023

23 September 2023

13 Juni 2023

13 Juni 2023

13 Juni 2023

13 Juni 2023

3 Mai 2023

3 Mai 2023

3 Mai 2023
Bedienungsanleitung Durchlauferhitzer und Boiler
- Durchlauferhitzer und Boiler Infiniton
- Durchlauferhitzer und Boiler Philips
- Durchlauferhitzer und Boiler Panasonic
- Durchlauferhitzer und Boiler Adler
- Durchlauferhitzer und Boiler Bosch
- Durchlauferhitzer und Boiler AEG
- Durchlauferhitzer und Boiler Siemens
- Durchlauferhitzer und Boiler ATAG
- Durchlauferhitzer und Boiler Buffalo
- Durchlauferhitzer und Boiler Electrolux
- Durchlauferhitzer und Boiler Fagor
- Durchlauferhitzer und Boiler Gorenje
- Durchlauferhitzer und Boiler Teka
- Durchlauferhitzer und Boiler Taurus
- Durchlauferhitzer und Boiler Vox
- Durchlauferhitzer und Boiler BEKO
- Durchlauferhitzer und Boiler Hotpoint
- Durchlauferhitzer und Boiler Inventum
- Durchlauferhitzer und Boiler Solac
- Durchlauferhitzer und Boiler Atlantic
- Durchlauferhitzer und Boiler CorberĂł
- Durchlauferhitzer und Boiler GE
- Durchlauferhitzer und Boiler Haier
- Durchlauferhitzer und Boiler Kelvinator
- Durchlauferhitzer und Boiler Midea
- Durchlauferhitzer und Boiler Rommer
- Durchlauferhitzer und Boiler Svan
- Durchlauferhitzer und Boiler Hitachi
- Durchlauferhitzer und Boiler Fakir
- Durchlauferhitzer und Boiler Waeco
- Durchlauferhitzer und Boiler Vaillant
- Durchlauferhitzer und Boiler Qlima
- Durchlauferhitzer und Boiler Junkers
- Durchlauferhitzer und Boiler Cata
- Durchlauferhitzer und Boiler De Dietrich
- Durchlauferhitzer und Boiler Remeha
- Durchlauferhitzer und Boiler Stiebel Eltron
- Durchlauferhitzer und Boiler Truma
- Durchlauferhitzer und Boiler Viessmann
- Durchlauferhitzer und Boiler Dimplex
- Durchlauferhitzer und Boiler Baxi
- Durchlauferhitzer und Boiler Eccotemp
- Durchlauferhitzer und Boiler Clage
- Durchlauferhitzer und Boiler Tesy
- Durchlauferhitzer und Boiler Worcester
- Durchlauferhitzer und Boiler Ariston Thermo
- Durchlauferhitzer und Boiler La Nordica
- Durchlauferhitzer und Boiler Ferroli
- Durchlauferhitzer und Boiler Nibe
- Durchlauferhitzer und Boiler Noveen
- Durchlauferhitzer und Boiler Orbegozo
- Durchlauferhitzer und Boiler SchÀfer Heiztechnik
- Durchlauferhitzer und Boiler Edilkamin
- Durchlauferhitzer und Boiler Jocel
- Durchlauferhitzer und Boiler Morco
- Durchlauferhitzer und Boiler Nefit
- Durchlauferhitzer und Boiler Oertli
- Durchlauferhitzer und Boiler Quantum
- Durchlauferhitzer und Boiler Technika
- Durchlauferhitzer und Boiler Thermoflow
- Durchlauferhitzer und Boiler Thermona
- Durchlauferhitzer und Boiler ACV
- Durchlauferhitzer und Boiler Biasi
- Durchlauferhitzer und Boiler OSO
- Durchlauferhitzer und Boiler Rinnai
- Durchlauferhitzer und Boiler IQE
- Durchlauferhitzer und Boiler Neopower
- Durchlauferhitzer und Boiler Rheinstrom
- Durchlauferhitzer und Boiler Amtrol
- Durchlauferhitzer und Boiler Joven
- Durchlauferhitzer und Boiler Rheem
- Durchlauferhitzer und Boiler LERAN
- Durchlauferhitzer und Boiler Kospel
- Durchlauferhitzer und Boiler Gleamous
- Durchlauferhitzer und Boiler Airthereal
- Durchlauferhitzer und Boiler Intellihot
- Durchlauferhitzer und Boiler Solahart
- Durchlauferhitzer und Boiler My-PV
- Durchlauferhitzer und Boiler ENEFT
Neueste Bedienungsanleitung fĂŒr -Kategorien-

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

1 Dezember 2024

25 November 2024