Broan QP236SS Evolution 2 Bedienungsanleitung

Broan Dunstabzugshaube QP236SS Evolution 2

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Broan QP236SS Evolution 2 (21 Seiten) in der Kategorie Dunstabzugshaube. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/21
MODELS QP230BC QP230BL QP230SS QP230WW
QP236BC QP236BL QP236SS QP236WW
QP242BC QP242BL QP242SS QP242WW
Page 1
WARNING
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended the manufac-by
turer. If questions, contact the manufacturer at the you have
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power at service off
panel and lock the service disconnecting means prevent to
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a the service tag, to
panel.
3. Installation and electrical wiring must be done a work by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
4. Sufficient air is needed proper combustion and exhaust-for
ing of gases through the flue (chimney) of fuel burning equip-
ment prevent backdrafting. Follow the heating equipment to
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. This product may sharp edges. Be careful avoid cuts have to
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must be vented the outdoors.always to
8. Use only metal ductwork.
9. Do not use this with solid-state speed control fan any device.
10. As an alternative, this product be installed with the may UL-
approved cord kit designated the product, following in-for
structions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and spillovers that ig-greasy may
nite. Heat oils slowly on or medium settings.low
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be al-
lowed accumulate on or filter.to fan
4. Use proper pan size. use cookware appropriate Always for
the size of the surface element.
TO TO REDUCE THE RISK OF INJURY PERSONS IN THE
EVENT OF A RANGE GREASE FIRE, OBSERVE THE TOP
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal then turn the burner. BE CAREFUL tray, off TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
EVOLUTIONTM 2
QP2 Series Range Hoods
READ AND SAVE THESE INSTRUCTIONS
FOR DOMESTIC COOKING ONLY
WARNING
2. NEVER PICK UP A FLAMING PAN — You be burned or may
spread the fire.
3. DO USE WATER, including dishcloths or towels - NOT wet
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know a Class ABC extinguisher and you have you
already know operate it.how to
B. The is small fire and contained in the area where it started.
C. The department is being called.fire
D. You can fight the with your back an exit.fire to
* Based on “Kitchen Safety Tips” published NFPA.Fire by
1. For indoor use only.
2. For general ventilating use only. Do not use exhaust haz-to
ardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbal-
anced impeller, keep drywall spray, construction dust, etc.,
off power unit.
4. Do not use cooking equipment greater than 60,000 over
BTU/hr. as the blower motor will shut down intermittantly.
5. Your hood motor has a thermal overload which will automati-
cally shut the motor if it becomes overheated. The motor off
will restart when it cools down. If the motor continues shut to
off and restart, the hood serviced.have
6. The of the hood MUST BE LESS than 24” and at a top NOT
maximum of 30” above cooktop best capture of cooking for
impurities.
7. This hood is not intended be used as a shelf.to
8. Please read specification label on product further infor-for
mation and requirements.
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.
NOTE If hood is be installed non-ducted:to
Purchase set a of (2) non-ducted filters 30” for wide
hoods (Model BPPF30) & 36” wide hoods (Model
BPPF36) or a set of (3) non-ducted filters 42” for wide
hoods (Model BPPF42) from your local distributor or
retailer and attach them the aluminum to mesh filters.
Register your product online at: www.broan.com
MODELS QP230BC QP230BL QP230SS QP230WW
QP236BC QP236BL QP236SS QP236WW
QP242BC QP242BL QP242SS QP242WW
Page 2
CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter,
fan and grease-laden surfaces. Use only a clean cloth and mild
detergent solution on stainless and painted surfaces.
Clean all-metal filters in the dishwasher using a non-phosphate
detergent. Discoloration of the filter may occur if using phosphate
detergents, or as a result of local water conditions - this will but
not affect filter performance. This discoloration is not covered by
the warranty.
Clean the non-duct recirculating filter surfaces frequently with
a damp cloth and a mild detergent. DO immerse filters in NOT
water or put in dishwasher. The special “Clean Sensefeature
indicates when the filter is be replaced. The blue and yellow to
strips will blend green when it is time change the filter. The to to
“Clean Sense feature works best when facing the cook-toward
ing surface. Change the non-duct recirculating filters 6 every
months. For replacement non-duct recirculating filters - purchase
S99010353 or Model BPPF30 30 wide hoods”, S99010354 for
or Model BPPF36 36” wide hoods, or S99010360 or Model for
BPPF42 42” wide hoods.for
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the motor with the exact service motor. The impeller should also
be replaced.
Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10 base.
OPERATION
Always turn the hood ON before cooking in order establish an to
air flow in the kitchen. After turning the range, let the hood run off
for few a minutes clear the air.to
Operate the hood as follows:
LIGHT (3 pushbutton switches)
Turns light on setting.to LOW
Turns light on MEDIUM setting.to
Turns light on HIGH setting.to
Pressing the same light again will turn lights OFF.button
A light above each indicates light setting.button
FAN (3 pushbutton switches)
Turns on speed.fan to LOW
Turns on MEDIUM speed.fan to
Turns on HIGH speed.fan to
Pressing the same again will turn OFF.fan button fan
A light above each indicates speed.button fan
NOTE
This hood utilizes an offset blower design achieve greater to
performance and lower sound levels. As a result, you notice may
that cooking impurities more attracted one side or appear are to
to be pulled-in faster than they appear on the opposite side. This
is completely normal. The hood has been designed and tested
to provide good capture of cooking impurities and odors under
all normal cooking conditions regardless of the cooking location
on the cooktop. Please note that cooking on the rear burners will
always result in the best capture of cooking impurities, regardless
of the hood design.
HEAT SENTRY SYSTEM
This range hood is equipped with an advanced Heat Sentry sys-
tem that monitors excessive temperature and automatically for
adjusts the the appropriate setting.fan to
1) If the fan is on, the Heat Sentry will increase the system fan
setting when the temperature is elevated. If the temperature con-
tinues rise, the Heat Sentry will continue increase to system to
the fan setting until the temperature is stabilized or reduced. The
flashing light above the fan button shows the Heat Sentry system
fan setting. Once the temperature has reduced, the Heat Sentry
system to will change the fan the original setting.
2) If the fan is off, the Heat Sentry system will automatically turn
the on its highest speed when the temperature is above fan to
normal. When the Heat Sentry is on, the light above the system
high speed fan will flash on and button off. After the temperature
has lowered normal, the speed will be reduced until the to fan
temperature has stabilized, then the will turn fan off.
CONTENTS
GREASE
FILTERS
(2 - FOR 30” & 36” HOODS)
3 - FOR 42” HOODS)
(1) 3¼” X 10”
DAMPER / DUCT
CONNECTOR
(1) 7” ROUND
DUCT
CONNECTOR
(4)
HALOGEN
BULBS
(1)
BULB
SUCTION
CUP TOOL
(1) PARTS BAG CONTAINING:
(3)
WIRE
NUTS
(1)
NON-DUCT
DIVERTER
INCLUDED WITH THE HOOD:
(9)
#8 X 1/4”
DUCT
CONNECTOR
SCREWS
(5)
#10 X 5/8”
RD. HD.
MOUNTING
SCREWS
(2)
#8 X 5/16”
MACHINE
SCREWS
&
(2)
#8 WASHERS
FOR NON-DUCT
DIVERTER
Note: Canadian version does not this function.have
MODELS QP230BC QP230BL QP230SS QP230WW
QP236BC QP236BL QP236SS QP236WW
QP242BC QP242BL QP242SS QP242WW
Page 3
3¼” X 10”
HORIZONTAL DUCTING
CABINET
BOTTOM
CABINET FRONT
HORIZONTAL DUCT
ACCESS HOLE
5¼"5¼"
HOOD
MOUNTING
SCREWS (5)
ELECTRICAL
ACCESS HOLE
(in wall)
4"
CENTER
LINE
WOOD SHIMS
(recessed-bottom
cabinets only)
67/ "8
13
/ "8
3/ "8
*
17 5/8" (42" hood)17 5/8" (42" hood)
14 5/8" (36" hood)14 5/8" (36" hood)
11 5/8" (30" hood)11 5/8" (30" hood)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
21/ "8
6
7/ "8
107/ "8
25/ "8
HOOD MOUNTING SCREWS (5)
45/ "8
8" DIA.
HOLE
7-IN. ROUND
DUCT
ACCESS
HOLE
7-IN. ROUND
DUCT
ACCESS
HOLE
11"
17 5/8" (42" hood)17 5/8" (42" hood)
14 5/8" (36" hood)14 5/8" (36" hood)
11
5/8" (30" hood)11 5/8" (30" hood)
*
7-IN. ROUND
DUCTING
2 Use the proper diagram below, placement of ductwork for
and electrical cutout in cabinet or wall. a non-ducted For
installation, DO cut a duct access hole.NOT
VERTICAL DUCT
ACCESS HOLE
¾"
107/8"
5¼"
5¼"
CENTER
LINE
HOOD MOUNTING SCREWS (5)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
CABINET
BOTTOM
17 5/8" (42" hood)
4½" 21/8"
25/8"
11"
67/8"
*
17 5/
8" (42" hood)
14 5/8" (36" hood)14 5/
8" (36" hood)
11 5/8" (30" hood)11 5
/8" (30" hood)
3¼” X 10
VERTICAL DUCTING
PREPARE HOOD LOCATION
SOFFIT
24" - 30" ABOVE
COOKING SURFACE
CABINET
3¼" X 10" DUCT
(For horizontal discharge)
WALL CAP
ROOF CAP 3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
HOODHOOD
1 Determine whether hood will discharge vertically (3¼”
x or 7 Round), or horizontally (3¼” x only). 10” 10 For
vertical or horizontal discharge, run ductwork between
the hood location and a roof cap or wall cap. best For
results, use a minimum number of transitions and
elbows.
FUSE
The contains Range Hood Control Board a Fuse to protect the
controls from power surges. If the fuse has opened (blown), the
green fan setting or light setting indicators will not operate properly
when the or light buttons pressed, and the and lights fan are fan
will not turn on.
A new fuse can be purchased at your local electronic supply
store. Use an 8A, 120V, mm diameter, 20 mm long, fast-acting, 5
cartridge-type fuse.
To replace the fuse:
1. Disconnect power at service entrance.
2. Remove filters and bottom pan.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics needed. are
FUSE RANGE HOOD CONTROL BOARD
* Note the extra wood shim and mounting near the screw
cabinet front, on the cabinet center line.


Produktspezifikationen

Marke: Broan
Kategorie: Dunstabzugshaube
Modell: QP236SS Evolution 2

Brauchst du Hilfe?

Wenn Sie Hilfe mit Broan QP236SS Evolution 2 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dunstabzugshaube Broan

Bedienungsanleitung Dunstabzugshaube

Neueste Bedienungsanleitung für -Kategorien-