Broan E60E30S Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Broan E60E30S (48 Seiten) in der Kategorie Dunstabzugshaube. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/48
E60000 SERIES
HB0073
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 & 14.
READ AND SAVE THESE INSTRUCTIONS
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711
REGISTER YOUR PRODUCT ONLINE AT: www.broan.com/register
SV08340 rev. 08
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will
restart when it will be cooled down. If the motor continues to
shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 24" and at a maximum of 30" above
the cooking surface.
6. Two installers are recommended because of the large size and
weight of this hood.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this hood, you
should make sure enough air is entering the house to replace
exhausted air. Use an appropriate make-up air device or open
a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the Broan Elite
E60E Series hood must be installed with one Broan exterior
blower model 331H, 332H, 335 or 336; or one Broan in-line
blower model HLB3, HLB6, HLB9 ou HLB11. Other blowers
cannot be substituted. (Exterior or in-line blowers sold
separately.)
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
HL0099
- E60000 SERIES RANGE HOOD SYSTEM -
INTERNAL BLOWERS
M 437ODEL
(H CIGH APACITY OOF AP R C )
M 421ODEL
(10" ROUND VERTICAL
I - D )N LINE AMPER
MODEL 441
(10" R )OUND WALL CAP
M 418 ODEL
(10" ROUND
ADJUSTABLE LBOW E )
M 410 ODEL
(10" R DOUND UCT
— 2 )FT. SECTIONS
M 427ODEL
(4½" 18½" X
TO 10" R , OUND
6" H - LIGH ATERAL)
M 423ODEL
(4½" 18½" X
TO 10" R - OUND
VERTICAL)
M 424ODEL
(4½" 18½" X
TO 10" R - OUND
H /R )ORIZ. FRONT EAR
M 454ODEL
(4½" 18½" X
TO 10" R - OUND
H )ORIZ. /RIGHT
M 453ODEL
(4½" 18½" X
TO 10" R - OUND
H )ORIZ. /LEFT
OPTIONAL DECORATIVE
FLUE AEE SERIES
OPTIONAL
NON-DUCTED RECIRCULATION KIT
ANKE60 SERIES
ADAPTER X 4½" 18½"
( SUPPLIED WITH
DOUBLE BLOWER HOOD )
DUAL BLOWER (1200 )CFM
36", 42" 48" AND ONLY
E60000 SERIES HOOD
RMP SERIES
BACKSPLASH
(STAINLESS STEEL WALL
COVERING WITH WARMING
SHELVES PTIONAL. O )
SINGLE LOWER B (600 CFM)
ADAPTER AMPER X/D 3¼" 10"
( SUPPLIED WITH
SINGLE BLOWER HOOD )
STANDARD
DUCT
(3¼" 10")X
MODEL 639
(3¼" X 10"
W C )ALL AP
MODEL 413
T RANSITION
(3¼" 10" 8")X TO
8" ROUND
STANDARD
DUCT
8" ROUND
ADJUSTABLE
ELBOW
M 415ODEL
(7" ROUND
ADJUSTABLE LBOW E )
M 407ODEL
(7" R OUND
— 2 )FT. SECTIONS
MODEL 412
TRANSITION
(3¼" 10" 7")X TO
MODEL 647
(7" R )OUND WALL CAP
M 634 644ODEL OR
(R C )OOF AP
M 643ODEL
(8" R )OUND WALL CAP


Produktspezifikationen

Marke: Broan
Kategorie: Dunstabzugshaube
Modell: E60E30S

Brauchst du Hilfe?

Wenn Sie Hilfe mit Broan E60E30S benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dunstabzugshaube Broan

Bedienungsanleitung Dunstabzugshaube

Neueste Bedienungsanleitung für -Kategorien-