Blomberg DKP 2010 X Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Blomberg DKP 2010 X (24 Seiten) in der Kategorie Dunstabzugshaube. Dieser Bedienungsanleitung war fĂĽr 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
Cooker Hood
Dunstabzugshaube
Hotte
DKP 2010 X
DKL 5010 X
Instructions Booklet
Bedienungsanleitung
Mode d’emploi
Instructieboekje
GEBRUIKSAANWIJZINGEN............................................ 12
WAARSCHUWING! ....................................................................... 12
AANSLUITING OP HET ELEKTRICITEITSNET ..................................... 12
INHOUD ...................................................................................... 12
INSTALLATIE ................................................................ 13
WERKING .................................................................... 14
ONDERHOUD ............................................................... 15
This appliance has been designed for use as either an (ducting to the EXTRACTION
outside) or RECIRCULATION (filtering) hood.
The measurements contained on the drawings in this booklet refer to two models
of cooker hood. Therefore, it is essential that you refer to the correct drawing
when taking measurements for installation.
WARNINGS!
- The minimum distance between the cooking surface and the metal grease filters on the
underside of the hood must be 650mm.
- This cooker hood must be installed in accordance with the installation instructions
and all requirements must be adhered to.
- If the room where the cooker hood is to be used contains a fuel burning appliance
such as a central heating boiler then its flue must be of the room sealed or balance
flue type.
- If other types of flue or appliances are fitted ensure that there is an adequate supply
of air to the room.
- When the cooker hood is used in conjunction with appliances supplied with energy
other than electricity, the negative pressure in the room must not exceed 0.4 mbar to
prevent fumes being drawn back into the room by the hood.
- The ducting system for this appliance must not be connected to any ventilation system
which is being used for any other purpose.
- The ducting system for this appliance must not be connected to any existing ventilation
system which is being used for any other purpose.
- Do not leave naked flames or carry out flambe cooking under this cooker hood.
CONNECTION TO THE MAINS
WARNING: DOUBLE INSULATED DO NOT EARTH
Before connecting to the mains supply ensure the mains voltage corresponds to the
voltage on the rating plate inside the hood.
This appliance is fitted with a 2 core mains cable and must be permanently connected to
the electricity supply via a double-pole switch having 3mm minimum contact gap on
each pole.
Aplied norms:
EN 60355-1/88 (CEI 61-50/89) CEI EN 61000-3-2/95
EN 60335-2-31 (CEI 61-92/91) CEI EN 61000-3-3/95
CEI EN 55014/94 EN 55104/95
CONTENTS
- 2 No Wall Brackets C
- 1 No Locking Washer D
- 1 No Ducting Flange E
- 1 No 150-120mm Ducting Spigot G
- 1 No Air Deflector H
- 2 No Charcoal Filters (Optional)L
INSTRUCTIONS FOR USE
1


Produktspezifikationen

Marke: Blomberg
Kategorie: Dunstabzugshaube
Modell: DKP 2010 X
Breite: 598 mm
Tiefe: 502 mm
Gewicht: 11000 g
Produktfarbe: Edelstahl
Steuerung: Tasten
Höhe: 1140 mm
Höhe (min): 740 mm
Höhe (max): 1140 mm
Paketgewicht: 15000 g
Typ: Wandmontiert
Maximale Absaugleistung: 390 mÂł/h
Anzahl Geschwindigkeiten: 3
Anzahl an Lampen: 2 GlĂĽhbirne(n)
Verpackungsabmessungen (BxTxH): 640 x 395 x 630 mm
Lampenleistung: 40 W
Absaugart: Abluft/Umluft
Anzahl der Motoren: 1
Intensivgeschwindigkeit: Nein

Brauchst du Hilfe?

Wenn Sie Hilfe mit Blomberg DKP 2010 X benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten