INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
To register your product online or for additional information visit www.BestRangeHoods.com
SV08544 rev. 11
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturers guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn power pack ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your power pack motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the power pack serviced.
5. The minimum hood distance above cooktop must not be less
than 24”. A maximum of 30” above cooktop is recommended for
best capture of cooking impurities.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
10. To reduce the risk of fire and electrical shock, the Best models
CP34, CP35 and CP37 Series should only be installed with
their own built-in blowers. Other blowers cannot be substituted.
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
HL0122
- CP34, CP35 AND CP37 POWER PACK SYSTEMS -
M 634 644ODEL OR
(R )OOF CAP
M 643ODEL
(8” R )OUND WALL CAP
M 418 ODEL
(10” R OUND
ADJUSTABLE ELBOW )
M 410 ODEL
(10” R OUND DUCT
— 2 )FT. SECTIONS
10” ROUND VERTICAL
IN LINE DAMPER SUPPLIED WITH- (
DUAL BLOWER POWER PACK )
MODEL 437
(HIGH CAPACITY
ROOF CAP)
MODEL 441
(10’ ROUND
WALL CAP)
10” ROUND ADAPTER
( SUPPLIED WITH DUAL BLOWER
POWER PACK )
DUAL BLOWER CFM (1200 )
S 48” UPPLIED WITH WIDTH
POWER ONLY PACK
S INGLE BLOWER CFM (600 )
S 30’, 36 UPPLIED WITH AND
42” WIDTH POWER PAC K ONLY
*300 CFM AIR FLOW REDUCER
INTEGRATED ON ODEL CP34 M
CP37
POWER PACK
CP34
POWER PACK*
CP35
POWER PACK
A /DAPTER DAMPER
8” ( ROUND SUPPLIED WITH
SINGLE BLOWER POWER PACKS )
8” ROUND
STANDARD DUCT
8” R OUND
ADJUSTABLE ELBOW


Produktspezifikationen

Marke: Best
Kategorie: Dunstabzugshaube
Modell: CP35I309SB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Best CP35I309SB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Dunstabzugshaube Best

Bedienungsanleitung Dunstabzugshaube

Neueste Bedienungsanleitung für -Kategorien-