Avantco UTM-2RR-G-HC Bedienungsanleitung

Avantco Kühlschrank UTM-2RR-G-HC

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Avantco UTM-2RR-G-HC (9 Seiten) in der Kategorie Kühlschrank. Dieser Bedienungsanleitung war für 21 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/9
05/2023
User Manual
Z Series
Reach-In Refrigeration
Models:
Standard Refrigerator Models
Standard Freezer Models
WiFi-Enabled Refrigerator Models
WiFi-Enabled Freezer Models
#178Z1RHC 29" Solid Door
#178Z1RGHC 29" Glass Door
#178Z2RHC 54" Solid Door
#178Z2RGHC 54" Glass Door
#178Z1FHC 29" Solid Door
#178Z2FHC 54" Solid Door
#178Z1RGWMS 29" Glass Door
#178Z1RWMS 29" Solid Door
#178Z2RGWMS 54" Glass Door
#178Z2RWMS 54" Solid Door
#178Z1FWMS 29" Solid Door
#178Z2FWMS 54" Solid Door
Note:
You should read this manual in its entirety prior to equipment setup, operation, and maintenance.
www.AvantcoRefrigeration.com
2
User Manual
www.AvantcoRefrigeration.com
Z Series Reach-In Refrigerators and Freezers
Warnings
DANGERRISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY
TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.
PELIGRORRIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA
SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA
REFRIGERANTE.
DANGERRISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES
RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE
FRIGORIGENE.
CAUTIONRISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR MANUAL/
OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST
BE FOLLOWED.
ATENCIONRIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE
EL MANUAL DE REPARACIÓN / GUÍA DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A ESTE
PRODUCTO. DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD.
ATTENTIONRISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONSULTER LE
MANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION. TOUTES LE
MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES.
CAUTIONRISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW
HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.
ATENCIONRIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACION DE LA TUBERÍA
REFRIGERANTE; SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO. REFRIGERANTE
INFLAMABLE UTILIZADO.
ATTENTIONRISQUE DE FEU OU D’EXPLOSION SI LA TUBULURE CONTENTANT LE FRIGORIGÈNE
EST PERFORÉE; SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN. LE FRIGORIGÈNE EST
INFLAMMABLE.
CAUTIONRISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW
HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT REGULATIONS.
ATENCIONRIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A REFRIGERANTE INFLAMABLE UTILIZADO.
SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO CONFORME A LAS REGLAS DE LA
MUNICIPALIDAD.
ATTENTION
RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. SUIVRE LES
INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX RÈGLEMENTATION
GOUVERNEMENTALE LOCAUX.
3
User Manual
www.AvantcoRefrigeration.com
Z Series Reach-In Refrigerators and Freezers
Installation
This unit is intended for use in a temperature-controlled environment of less than 75 degrees
Fahrenheit and 60% relative humidity. Malfunction due to improper conditions is not covered
under warranty.
Important! Please Read Before Installation
If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet
to promote proper air flow. Failure to install the shelves properly is considered user error and is
not covered by warranty.
If the unit has recently been transported on its side, please let unit stand upright for a minimum
of 24 hours before plugging it in.
Make sure that the unit has reached the desired temperature before loading the unit with
products. This unit is meant for keeping cold products cold, not chilling warm products.
Make sure that there is proper ventilation around the unit in the area where it will operate.
Make sure all accessories are installed (i.e., shelves, shelf clips, casters) before plugging the
unit in.
Do not attempt to remove or repair any component of the unit. Consult an authorized service
technician for servicing/repair.
Do not hang on doors or stand inside the unit.
Please read through the manual in its entirety.
This unit is designed to perform in a temperature-controlled environment at 60% relative
humidity. The unit should be located away from doors, air ducts, and fans that could disrupt
airflow and negatively impact performance.
Cabinet Location Guidelines
Install the unit on strong and leveled surfaces.
• If the surface is uneven, the unit may be noisy.
• The unit may malfunction if the surface is uneven.
Install the unit in an indoor, well-ventilated area.
• For best performance, please maintain clearance of 6" on the back of the unit.
• Do not use outdoors. For indoor use only.
• Avoid direct sunlight.
Do not store any products, boxes, or materials on top of the refrigerator. This is the area
where the refrigeration system exhausts heat. If blocked it will cause damage to the
refrigeration system and will void the warranty.


Produktspezifikationen

Marke: Avantco
Kategorie: Kühlschrank
Modell: UTM-2RR-G-HC

Brauchst du Hilfe?

Wenn Sie Hilfe mit Avantco UTM-2RR-G-HC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Kühlschrank Avantco

Bedienungsanleitung Kühlschrank

Neueste Bedienungsanleitung für -Kategorien-