OVERVIEW
The OM11 is a re-issue of the original OM1, a hand-made microphone ïŹrst issued in
1985. Designed, assembled, machined and tested by Audix in the USA, the OM11 is
a dynamic vocal microphone used for a wide variety of live, studio, and broadcast
applications. The OM11 is known for its sharp, crisp vocal sound, resistance to
feedback and ability to handle high sound pressure levels without distortion.
The OM11 is characterized with a tight and uniformly controlled hypercardioid polar
pattern which helps to isolate the vocals from the rest of the instruments on stage.
With a wide frequency range of 50 Hz - 18 kHz, the OM11 employs a VLMℱ(Very
Low Mass) diaphragm for a very clean and natural sound with exceptional transient
response.
The OM11 response is tailored to cut through the mix, providing presence and
articulation to the vocals even at very high stage volumes. In addition to having
extremely low handling noise, the OM11 is well balanced, comfortable to hold,
durable and manufactured with very high standards and tight tolerances.
Roadworthy construction includes a two stage machined brass body, durable black
e-coat ïŹnish, dent resistent steel mesh grill and gold plated XLR connector.
SUPPLIED ACCESSORIES
MC1 - Heavy-duty nylon molded clip with brass insert
P1 - Carrying pouch
OPTIONAL ACCESSORIES
WS357 - Optional high quality external foam windscreen for reducing wind,
sibilance, and pop noise.
CBL20 - 20’ premium XLR-XLR balanced mic cable. Quad conductor, twisted pair with
braided shield for maximum conductivity. 6mm PVC jacketed.
CBLDR25 - 25’ premium right angle XLR-XLR balanced mic cable. Quad conductor,
twisted pair with braided shield for maximum conductivity. 6mm PVC jacketed.
T50K - Professional impedance matching transformer that allows a low impedance
mic to be connected to a high impedance input.
TRIPOD - Metal tripod desktop stand for use with any 5/8” threaded mic clip.
Dynamic Vocal Microphone
FEATURES
· Concert level, professional vocal mic for live
sound, broadcast and studio
· Clear, accurate vocal sound that cuts
through the mix
· Precision machined brass construction
· Extremely low handling noise
· Handles exceptionally high SPLs without distortion
· VLM Capsule
· Designed, assembled & tested in the USA
· 5 year warranty
APPLICATIONS
·Lead or backing vocals
·Live recording
·Broadcast
·Home studio - vocal and instrument
MC1 P1 WS357 CBL20 CBLDR25 T50K TRIPOD
Hi
Lo
FREQUENCY RESPONSE
POLAR PATTERNS
ARCHITECT AND ENGINEER SPECIFICATIONS
The microphone shall be of the dynamic type and the polar pattern of the
microphone shall be hypercardioid. The nominal output impedance shall be
equal to 200 ohms at 1 kHz. The microphone shall have a sensitivity of 1.9 mV/
Pa at 1 kHz and a sound pressure level ≄140 dB. The microphone body shall
be machined of brass and the grill cap shall be steel wire mesh. The overall
dimensions shall be 21.7 mm in diameter at the base, 54 mm in diameter at the
widest point on the grill and 179 mm in length.
OPERATION AND MAINTENANCE
The OM11 is a low impedance microphone and should be plugged into the
“mic level” input of your console, mixer, or recording device. Please note that
your microphone does not require phantom power and will not be aïŹ€ected
in any way by phantom power should it be running simultaneously while the
microphone is in operation. Avoid plugging or unplugging the microphone
from a PA system unless the channel is muted or the volume of the system
turned down. Failure to do so may result in a loud “popping” noise which could
seriously damage the speakers in the PA system.
The OM11 is manufactured to exacting specs with roadworthy construction.
However, the capsule is highly sensitive and should be handled with care. Avoid
extreme temperatures and be sure to store your microphone in the pouch
provided when not in use. Moisture of any kind can adversely eïŹ€ect the sound
and performance of your microphone.
USER TIPS
The OM11 has a tight pick-up pattern in order to help eliminate sound from
other instruments on stage from “bleeding” into the microphone. For best results,
it is important to sing directly into the mic at close proximity (within 2 inches).
When using ïŹ‚oor monitors, position the microphone so that it is parallel to the
ïŹ‚oor. When using multiple microphones on a live performance stage, allow a
distance of 2-3 feet between mics to avoid phase issues.
Further miking techniques may be found at www.audixusa.com.
ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
www.audixusa.com
503.682.6933 Fax: 503.682.7114
Audix Corporation 9400 SW Barber St. Wilsonville, OR 97070
ver 3.0 05-16
PRODUCT REGISTRATION: Please register your product online at www.audixusa.com/docs_12/about/product_registration.shtml.
SERVICE AND WARRANTY:
This microphone is under warranty for a period of 5 years to be free of defects in material and workmanship. In the event of a product failure due to materials or
workmanship, Audix will repair or replace said product at no charge with proof of purchase. Audix does not pay or reimburse shipping costs for warranty repairs or returns. The warranty excludes
any causes other than manufacturing defects, such as normal wear, abuse, environmental damage, shipping damage or failure to use or maintain the product per the supplied instructions. No
Implied Warranties: All implied warranties, including but not limited to implied warranties of merchantability and ïŹtness for a particular purpose are hereby excluded. The liability of Audix, if any,
for damages relating to allegedly defective products shall be limited to the actual price paid by Dealer for such products and shall in no event include incidental or consequential damages of
any kind. Should your microphone fail in any way, please contact the Audix Service department at 503.682.6933. A Return Authorization is required before returning any product. OTHER THAN
THIS WARRANTY, AUDIX MAKES NO WARRANTIES, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS, THE USE OF THE PRODUCTS, THE PERFORMANCE OF THE PRODUCTS. AUDIX SHALL
NOT BE LIABLE FOR SPECIAL INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES ARISING FROM OR BASED ON THE SALE, USE, STORAGE OR DISPOSAL OF THE PRODUCTS, AUDIX’S
SERVICE WORK, BREACH OF WARRANTY, BREACH OF CONTRACT. NEGLIGENCE, OR ANY OTHER THEORY OF LIABILITY, EVEN IF AUDIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
DIMENSIONS (mm)
SPECIFICATIONS
OM11
Transducer Type
Dynamic
Frequency Response
50 Hz - 18 kHz
Polar Pattern
Hypercardioid
Output Impedance
200 ohms
Sensitivity
1.9 mV / Pa @ 1k
Capsule Technology
VLM Type C
OïŹ€-Axis Rejection
>30 dB
Maximum SPL
≄140 dB
Power Requirements
None
Connector
3-pin XLRm
Polarity
Positive pressure on diaphragm
produces positive voltage on
pin 2 relative to pin 3 of output
XLR connector
Materials / Finish
Zinc Alloy / Black Finish
Weight
370 g / 13 oz
Length
179 mm / 7 in


Produktspezifikationen

Marke: Audix
Kategorie: Mikrofon
Modell: OM11
Tiefe: 179 mm
Produktfarbe: Schwarz
Übertragungstechnik: Kabelgebunden
Impedanz: 200 Ohm
Höhe: 54 mm
Typ: BĂŒhnen-/Auftrittsmikrofon
GerÀteschnittstelle: XLR-3
Mikrofon-Frequenz: 50 - 18000 Hz
Ausrichtung des integrierten Mikrofons: Kardioide
GerĂ€uschunterdrĂŒckung: Ja
Anzahl enthaltener Produkte: 1 StĂŒck(e)
Kompatible Produkte: MC1\r\nWS357\r\nCBL-20\r\nT50K
XLR-Out: Ja
Microphon Abmessungen (D x H): 179 x 54 mm
Mikrofongewicht: 370 g
Output Widerstand: 200 Ohm
Tiefe (imperial): 7 "