COOKER HOOD
INSTRUCTION MANUAL
Read this manual carefully before operation
Pictures in this manual are for reference only, the product in kind prevail.
RECOMMENDATIONS AND SUGGESTIONS
The instructions for Use apply to several versions of this appliance. Accordingly, you
may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
The manufacturer will not be held liable for any damages resulting from incorrect or
improper installation.
The minimum safety distance between the cooker top and the extractor hood is 650
mm (some models can be installed at a lower height, please refer to the paragraphs
on working dimensions and installation).
Check that the mains voltage corresponds to that indicated on the rating plate fixed to
the inside of the hood.
For Class appliances, check that the I domestic power supply guarantees adequate
earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120mm.
The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion flumes
(boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning
appliances),a sufficient degree of aeration must be guaranteed in the room in order to
prevent the backflow of exhaust gas. The kitchen must have an opening
communicating directly with the open air in order to guarantee the entry of clean air.
When the cooker hood is used in conjunction with appliances supplied with energy
other than electric, the negative pressure in the room must not exceed 0,04 mbar to
prevent fumes being drawn back into the room by the cooker hood.
In the event of damage to the power cable, it must be replaced by the manufacturer or
by the technical service department, in order to prevent any risks.
If the instructions for installation for the gas hob specify a greater distance specified
above, this has to be taken into account. Regulations concerning the discharge of air
have to be fulfilled.
USE
The extractor hood has been designed exclusively for domestic use to eliminate
kitchen smells.
Never use the hood for purposes other than for which it has been designed.
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that
it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil can burst
into flames.
Do not flame er the range hood; risk of fire.und
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children should be supervised to ensure that they do not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
“CAUTION: Accessible parts may become hot when used with cooking ances”. appli
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out any
maintenance work.
Clean and/or replace the Filters after the specified lime period (Fire hazard).
Clean the hood using a damp cloth and a neutral liquid detergent.
The appliance uses 4 hob elements at most.
The symbol is packaging indicates that this product may not be treated as household
waste. Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correctly, you
will help prevent potential negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste handling of this product. For more
detailed information about recycling of this product, please contact your local city office,
your household waste disposal service or the shop where you purchased the product.
EN-2
COMPONENTS
Ref.
Qty.
Product Components
1
1
Hood Body, complete with: Controls, Light,
Blower, Filter.
2.1
1
Lower Decorative Chimney ( optional )
2.2
1
Upper Decorative Chimney ( optional )
3
1
Flange ( optional )
4
1
Exhaust Pipe
5
2
The Activated Charcoal filter ( optional )
Ref.
Qty
.
10
7
11
7
12 6 Screws 4.2 x 9.5
13 2 Mounting Bracket
20 1 Hood fixing bracket ( optional )
21 1 Chimney fixing bracket (0/1 optional )
20 11
1
12
21 10
13
Qty. Documentation
Instruction Manual
1
21 11
12
2.2 4
10
20 3
2.1
11
5
10
13
12
EN-3


Produktspezifikationen

Marke: Aspes
Kategorie: Türklingel
Modell: ACPD600A3IN
Breite: 600 mm
Tiefe: 430 mm
Gewicht: 17000 g
Produktfarbe: Schwarz
Steuerung: Berührung
AC Eingangsspannung: 220 - 240 V
AC Eingangsfrequenz: 50 Hz
Energieeffizienzklasse: A+++
Energieeffizienzskala: A+++ bis D
Anschlusswert: 82 W
Jährlicher Energieverbrauch: 14 kWh
Geräuschpegel: 59 dB
Maximale Absaugleistung: 650 m³/h
Motorleistung: 80 W
Anzahl Geschwindigkeiten: 4
Anzahl an Lampen: 2 Glühbirne(n)
Lichtintensität: 250 Lux
Anzahl Filter: 3 Stück(e)
Leuchtmitteltyp: LED
Fettfiltertyp: Aluminium
Fluiddynamische Effizienzklasse: A
Beleuchtungs-Effizienzklasse: A
Ölfilter-Effizienzklasse: D
Durchmesser Auspuffanschluss: 150 mm
Geschirrspülerfilter: Ja
Höhe ohne Abzug: 440 mm