DEHUMIDIFIER
DRY CLOUD 11-13
OPERATING INSTRUCTIONS
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage.
Keep these instructions in a safe place for future reference.
EN
14 V 09/19
The Refrigerant R290
ï‚· To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The refrigerant is the fluoride R290 = 3 GWP (Global warming
potential). This refrigerant is flammable and inodorous. It can lead to explosions
under certain conditions; however the flammability of this refrigerant is very low and
it can be ignited only by fire.
ï‚· Compared to other common refrigerants, R290 is a non-polluting refrigerant with no
harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has
very good thermodynamic features which lead to a really high energy efficiency.
The units therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways
other than those recommended by the manufacturer. Should repair be necessary, contact
your nearest authorized Argoclima Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance has to be stored in a room that doesn’t have
any continuously operating ignition sources. (for example: open flames, an operating gas
appliance or an operating electric heater.) Do not pierce or burn.
Appliance has to be installed, operated and stored in a room with a floor area larger than 4
m2.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance filled with flammable gas R290.
Before installing and using the appliance, read the owner’s manual.
Before repairing the appliance, read the service manual.
15 V 09/19
GENERAL OPERATING AND SAFETY INSTRUCTIONS
ï‚· This appliance is a highly efficient dehumidifier, designed for
domestic use only!
ï‚· Use this dehumidifier only as outlined in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock or malfunctions.
ï‚· The unit contains refrigerant; keep it vertical at all times.
ï‚· Once you have opened the unit, keep it vertical to allow the
refrigerant to stabilise and wait two hours before operating it.
ï‚· Ensure that the required voltage and frequency (220-240V/50Hz)
match the available power source.
ï‚· This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved.
ï‚· Children shall not play with the appliance.
ï‚· Cleaning and user maintenance shall not be made by children
without supervision.
ï‚· Make sure the plug is inserted fully. Do not use multiple adapters.
Do not touch the plug with wet hands. Make sure the plug is clean.
ï‚· Children aged between 3 and 8 years must only be able to turn
the appliance on/off, provided that the appliance has been placed
in its normal operating position, that instructions have been given
on how to use the equipment safely, and that its risks have been
understood.
ï‚· Children aged between 3 and 8 years must not be able to plug in,
adjust, clean or perform any maintenance on the appliance.
ï‚· Disconnect the mains power when the appliance is not in use
or during cleaning operations. Keeping the appliance plugged
in may cause electric shocks or accidents.


Produktspezifikationen

Marke: Argoclima
Kategorie: Luftentfeuchter
Modell: Dry Cloud 13

Brauchst du Hilfe?

Wenn Sie Hilfe mit Argoclima Dry Cloud 13 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftentfeuchter Argoclima

Bedienungsanleitung Luftentfeuchter

Neueste Bedienungsanleitung für -Kategorien-