Argo Hyder 13 Bedienungsanleitung

Argo Klimaanlage Hyder 13

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Argo Hyder 13 (13 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 31 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/13
14 V 01/18
LOCAL AIR CONDITIONER
OPERATING INSTRUCTIONS
Read the instructions carefully before operating the appliance or carrying out maintenance work.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or
damage. Store these instructions in a safe place for future reference.
EN
15 V 01/18
GENERAL OPERATING AND SAFETY INSTRUCTIONS
This appliance is a local air gned for domesti conditioner desi c use.
Only use this air conditioner as described in this manual.
Ensure that the required voltage and frequency (220-240 V/50 Hz)
match the available power source.
Fuse style FSD or 50F AC250V, the electricity passing through the
fuse cannot be above 3.15A.
This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Ensure that the electricity system is able to deliver the operating
current required by the air conditioner, in addition to that normally
absorbed by other appliances (electrical appliances, lighting system,
etc.). Please refer to the maximum power input data shown on the
air conditioner's data plate.
Connection to the electricity grid must take place in accordance with
current installation standards.
Ensure that the automatic switches and system protection valves
are able to withstand a start-up current of 6A (normally for less than
1 second).
The power socket must always include an efficient earth connection.
Make sure that the plug is properly inserted into the socket. Do not
use multiple adapters. Do not touch the plug with wet hands. Make
sure that the plug is clean.
Do not use the plug for starting/stopping the air conditioner: use the
ON/OFF button on the remote control or control panel instead.
16 V 01/18
Do not install the air conditioner in rooms potentially subject to water
sprays (e.g. laundries).
This air conditioner can be used by children of 8 years or older and
by persons with reduced physical, sensory and mental abilities, or
lacking the necessary experience and knowledge, provided they are
supervised or instructed on its use by a person responsible for their
safety, so that they are fully aware of the attendant risks.
Before moving or cleaning the appliance, ensure that it is unplugged
from the socket.
Do not move the air conditioner while it is operating; first turn the
appliance off, then check and remove any condensate which may
have formed.
To turn the appliance off, set the remote control to OFF and remove
the plug from the socket. Pull on the plug only. Do not pull the cord.
Do not use the appliance if the cord or plug are damaged.
Contact a service centre to replace a damaged power cord, so as to
avoid any safety risks.
If your air conditioner is not fitted with a supply cord and a plug, an
all-pole switch must be installed in the fixed wiring and the distance
between contacts should be no less than 3.0 mm.
PRECAUTION!
Do not insert any objects into the air conditioner: this is very
dangerous as the fan turns at high speed.
Ensure that air circulates freely around the unit. Do not cover
the air intake and delivery grilles with drapes or any other
means.
WARNING!
The air conditioner must be positioned at least 50 cm from the wall
or any other obstacles, on a flat and stable surface so as to avoid
water leaks.


Produktspezifikationen

Marke: Argo
Kategorie: Klimaanlage
Modell: Hyder 13
Display-Typ: LED
Timer: Ja
Breite: 430 mm
Tiefe: 360 mm
Gewicht: 31000 g
Produktfarbe: Weiß
Höhe: 722 mm
Lenkrollen: Ja
AC Eingangsspannung: 220 - 240 V
AC Eingangsfrequenz: 50 Hz
Eingebautes Display: Ja
Fernbedienung enthalten: Ja
Typ: Einteilige mobile Klimaanlage
Abnehmbarer Wasserbehälter: Ja
Betriebsanleitung: Ja
Kältemittelart: R410A
Geräuschpegel: 65 dB
Fernbedienung: Ja
Timer-Typ: Digital
Anzahl Geschwindigkeiten: 3
Luftfilter: Ja
Klimaanlage Funktionen: Cooling, Dehumidifying, Fan, Heating
Kühlleistung (max): 13000 BTU/h
Kühlkapazität in Watt (nominal): 3500 W
Kühlleistung in Watt (max): - W
Heizkapazität in Watt (nominal): 2350 W
Heizleistung in Watt (max): - W
Luftstrom (hohe Geschwindigkeit): 400 m³/h
Energieeffizienzklasse (Kühlen): A
Energieverbrauch pro Stunde (Kühlung): 1.3 kWh
Energieverbrauch pro Stunde (Heizung): 1 kWh
Jährlicher Energieverbrauch (Kühlung): - kWh
Schlauchlänge: 1.5 m
Schlauchdurchmesser: 140 mm
Heizleistung (max): 9000 BTU/h
Energieeffizienzklasse (Heizen): A
Kühlung Energieeffizienz: 2610
Heizung Energieeffizienz: 2350
Deshumidifizierende Kapazität: 1.2 l/h

Brauchst du Hilfe?

Wenn Sie Hilfe mit Argo Hyder 13 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Argo

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-