Amprobe 35XP-A Bedienungsanleitung
Amprobe
Multimeter
35XP-A
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Amprobe 35XP-A (84 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/84

5XP-A
15XP-A
35XP-A
Compact
Digital
Multimeters
Users Manual
• Manual de uso
• Mode d'emploi
• Bedienungshandbuch
• Manuale d'Uso

2A MAX
FUSED
CAT 600V
CAT 1000V
CAT 300V
COM A
MAX
1000V
750V
Hz Te mp
V
mA
A
mA
400
1000
A
A
35XP-A
RANGE NON
CONT ACT
VOL TAGE
HOLD
V
HZ
V
auto -off
°C
OFF
°F
mA
A
A
1832 400
5
6
4
2
35XP-A
3
1

5XP-A
15XP-A
35XP-A
Compact Digital Multimeters
Users Manual
• Manual de uso
• Mode d’emploi
• Bedienungshandbuch
• Manuale d’Uso
PN 2728995
July 2006
©2006, Amprobe Test Tools.
All rights reserved. Printed in Taiwan.

Limited Warranty and Limitation of Liability
Your Amprobe® product will be free from defects in material and workmanship for
1 year from the date of purchase. This warranty does not cover fuses, disposable
batteries or damage from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Amprobe®
’s behalf. To obtain service during the
warranty period, return the product with proof of purchase to an authorized
Amprobe® Test Tools Service Center or to a Amprobe
® dealer or distributor. See
Repair Section above for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL
OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY -
INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE
OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL
NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some
states or countries do not allow the exclusion or limitation of an implied warranty or
of incidental or consequential damages, this limitation of liability may not apply to
you.

7
Testing Logic Levels (15XP-A only) See Figure -13-
The 15XP-A tests logic levels for TTL logic. The meter displays plus a ∧
∧
∧
∧∧ for a
high-level (true) condition. The meter beeps and displays an and a ∨
∨
∨
∨∨ for a
low-level (false) condition. See Specifications for the logic 1 and logic 0 voltage
limits. Out-of-limits indications are displayed as only, no ∧
∧
∧
∧∧ ∨
∨
∨
∨ ∨, or beep occur.
1. . Set the Function Switch to LOGIC
2. . Connect the test leads: Red to , Black to COM
3. Connect the black lead to logic common.
4. Connect the red lead to the logic test point.
5. Read the display.
Additional Features
Input Test Lead Warning
The meter emits a continuous tone when a test lead is placed in the mA or A input
jack and the Function/Range Switch is not set to a correct current position. (If the
meter is connected to a voltage source with leads connected for current, very high
current could result). All current ranges are protected by fast acting fuses.
MIN MAX Measurements (Model 5XP-A only)
The MIN MAX feature reads and updates the display to show the maximum or
minimum value measured after you press the MIN MAX button.
Pressing the MIN MAX button for less than 1 second will put the meter into a mode
of displaying the maximum or minimum readings. Each time the button is pressed,
the meter will cycle to the next display mode. Press the MIN MAX button for more
than 1 second to disable this feature.
Auto Power Off (Models 15XP-A and 35XP-A only)
Auto Power Off is a battery saving feature that puts the meter into a sleep mode if
the Function/Range Switch has not changed position in the last 10 minutes. To
wake the meter turn the Function/Range Switch to another position.
The Auto Power Off feature can be disabled to keep the meter from going to sleep.
To disable the Auto Power Off feature use the following procedure:
1. . Set the Function Switch to OFF
2. Press and hold the Range button while turning the Function Switch from OFF
to the desired function.
3. Release the Range button. The Auto Power Off feature will remain disabled until
the meter is turned off and then on.
HOLD Measurements
The HOLD button causes the meter to capture and continuously display a
measurement reading. To use the HOLD feature make a measurement, and then,
after the reading has stabilized, momentarily press the HOLD button. You can
remove the test leads and the reading will remain on the display. Pressing the
HOLD button again releases the display.
Produktspezifikationen
Marke: | Amprobe |
Kategorie: | Multimeter |
Modell: | 35XP-A |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Amprobe 35XP-A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Amprobe

10 August 2024

7 August 2024

4 August 2024

4 August 2024

29 Juli 2024

29 Juli 2024

27 Juli 2024

25 Juli 2024

13 Juli 2024

10 Juli 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Velleman
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter EMOS
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

13 Oktober 2024

9 Oktober 2024

5 Oktober 2024

5 Oktober 2024

3 Oktober 2024